Topic Review
Atmospheric-pressure Chemical Ionization
Atmospheric pressure chemical ionization (APCI) is an ionization method used in mass spectrometry which utilizes gas-phase ion-molecule reactions at atmospheric pressure (105 Pa), commonly coupled with high-performance liquid chromatography (HPLC). APCI is a soft ionization method similar to chemical ionization where primary ions are produced on a solvent spray. The main usage of APCI is for polar and relatively less polar thermally stable compounds with molecular weight less than 1500 Da. The application of APCI with HPLC has gained a large popularity in trace analysis detection such as steroids, pesticides and also in pharmacology for drug metabolites.
  • 1.6K
  • 01 Dec 2022
Topic Review
Shopping Hours
Customs and regulations for shopping hours for sunday (times that shops are open) vary from countries to cities.
  • 780
  • 01 Dec 2022
Topic Review
Mars Helicopter Ingenuity
Ingenuity (also known as the Mars Helicopter) is a robotic helicopter that is planned to be used to test the technology to scout interesting targets on Mars, and help plan the best driving route for future Mars rovers. The small drone helicopter is planned for deployment in 2021 from the Perseverance rover as part of the Mars 2020 mission. It is expected to fly up to five times during its 30-day test campaign, early in the rover's mission, as it is primarily a technology demonstration. Each flight is planned to take no more than three minutes, at altitudes ranging from 3 to 10 m above the ground. It could potentially cover a distance of up to 300 metres (980 ft) per flight. It can use autonomous control and communicate with the Perseverance rover directly after each landing. If it works as expected, NASA could build on the design for future Mars aerial missions. MiMi Aung is the project lead. Other contributors include AeroVironment Inc., NASA Ames Research Center, and NASA Langley Research Center.
  • 704
  • 01 Dec 2022
Topic Review
Introduction to the Mathematics of General Relativity
The mathematics of general relativity is complex. In Newton's theories of motion, an object's length and the rate at which time passes remain constant while the object accelerates, meaning that many problems in Newtonian mechanics may be solved by algebra alone. In relativity, however, an object's length and the rate at which time passes both change appreciably as the object's speed approaches the speed of light, meaning that more variables and more complicated mathematics are required to calculate the object's motion. As a result, relativity requires the use of concepts such as vectors, tensors, pseudotensors and curvilinear coordinates. For an introduction based on the example of particles following circular orbits about a large mass, nonrelativistic and relativistic treatments are given in, respectively, Newtonian motivations for general relativity and Theoretical motivation for general relativity.
  • 785
  • 01 Dec 2022
Topic Review
Frost Diagram
A Frost diagram or Frost–Ebsworth diagram is a type of graph used by inorganic chemists in electrochemistry to illustrate the relative stability of a number of different oxidation states of a particular substance. The graph illustrates the free energy vs oxidation state of a chemical species. This effect is dependent on pH, so this parameter also must be included. The free energy is determined by the oxidation–reduction half-reactions. The Frost diagram allows easier comprehension of these reduction potentials than the earlier-designed Latimer diagram, because the “lack of additivity of potentials” was confusing. The free energy ΔG° is related to reduction potential E in the graph by given formula: ΔG° = −nFE° or nE° = −ΔG°/F, where n is the number of transferred electrons, and F is Faraday constant (F = 96,485 J/(V·mol)). The Frost diagram is named after Arthur Atwater Frost (de), who originally created it as a way to "show both free energy and oxidation potential data conveniently" in a 1951 paper.
  • 3.3K
  • 01 Dec 2022
Topic Review
High Entropy Alloys
High-entropy alloys (HEAs) are alloys that are formed by mixing equal or relatively large proportions of (usually) five or more elements. Prior to the synthesis of these substances, typical metal alloys comprised one or two major components with smaller amounts of other elements. For example, additional elements can be added to iron to improve its properties, thereby creating an iron based alloy, but typically in fairly low proportions, such as the proportions of carbon, manganese, and the like in various steels. Hence, high entropy alloys are a novel class of materials. The term “high-entropy alloys” was coined because the entropy increase of mixing is substantially higher when there is a larger number of elements in the mix, and their proportions are more nearly equal. These alloys are currently the focus of significant attention in materials science and engineering because they have potentially desirable properties. Furthermore, research indicates that some HEAs have considerably better strength-to-weight ratios, with a higher degree of fracture resistance, tensile strength, as well as corrosion and oxidation resistance than conventional alloys. Although HEAs have been studied since the 1980s, research substantially accelerated in the 2010s.
  • 2.5K
  • 01 Dec 2022
Topic Review
Osmium-194
Osmium (76Os) has seven naturally occurring isotopes, five of which are stable: 187Os, 188Os, 189Os, 190Os, and (most abundant) 192Os. The other natural isotopes, 184Os, and 186Os, have extremely long half-life (1.12×1013 years and 2×1015 years, respectively) and for practical purposes can be considered to be stable as well. 187Os is the daughter of 187Re (half-life 4.56×1010 years) and is most often measured in an 187Os/188Os ratio. This ratio, as well as the 187Re/188Os ratio, have been used extensively in dating terrestrial as well as meteoric rocks. It has also been used to measure the intensity of continental weathering over geologic time and to fix minimum ages for stabilization of the mantle roots of continental cratons. However, the most notable application of Os in dating has been in conjunction with iridium, to analyze the layer of shocked quartz along the Cretaceous–Paleogene boundary that marks the extinction of the dinosaurs 66 million years ago. There are also 30 artificial radioisotopes, the longest-lived of which is 194Os with a half-life of six years; all others have half-lives under 94 days. There are also nine known nuclear isomers, the longest-lived of which is 191mOs with a half-life of 13.10 hours. All isotopes and nuclear isomers of osmium are either radioactive or observationally stable, meaning that they are predicted to be radioactive but no actual decay has been observed.
  • 315
  • 01 Dec 2022
Topic Review
Flow-Induced Vibration
Flow-induced vibration (FIV) of bluff body structures is a classical bidirectional flow–structure interaction problem, which is linked to various fluid dynamics phenomena (e.g., boundary-layer separation, vortex formation and shedding, hydrodynamic loading on the structures) as well as structure vibrations.
  • 1.6K
  • 01 Dec 2022
Topic Review
Bloch Wave
A Bloch wave (also called Bloch state or Bloch function or Bloch wavefunction), named after Swiss physicist Felix Bloch, is a kind of wave function which can be written as a plane wave modulated by a periodic function. By definition, if a wave is a Bloch wave, its wavefunction can be written in the form: where [math]\displaystyle{ \mathbf{r} }[/math] is position, [math]\displaystyle{ \psi }[/math] is the Bloch wave, [math]\displaystyle{ u }[/math] is a periodic function with the same periodicity as the crystal, the wave vector [math]\displaystyle{ \mathbf{k} }[/math] is the crystal momentum vector, [math]\displaystyle{ \mathrm{e} }[/math] is Euler's number, and [math]\displaystyle{ \mathrm{i} }[/math] is the imaginary unit. Bloch waves are important in solid-state physics, where they are often used to describe an electron in a crystal. This application is motivated by Bloch's theorem, which states that the energy eigenstates for an electron in a crystal can be written as Bloch waves (more precisely, it states that the electron wave functions in a crystal have a basis consisting entirely of Bloch wave energy eigenstates). This fact underlies the concept of electronic band structures. These Bloch wave energy eigenstates are written with subscripts as [math]\displaystyle{ \psi_{n\mathbf{k}} }[/math], where [math]\displaystyle{ n }[/math] is a discrete index, called the band index, which is present because there are many different Bloch waves with the same [math]\displaystyle{ \mathbf{k} }[/math] (each has a different periodic component [math]\displaystyle{ u }[/math]). Within a band (i.e., for fixed [math]\displaystyle{ n }[/math]), [math]\displaystyle{ \psi_{n\mathbf{k}} }[/math] varies continuously with [math]\displaystyle{ \mathbf{k} }[/math], as does its energy. Also, for any reciprocal lattice vector [math]\displaystyle{ \mathbf{K} }[/math], [math]\displaystyle{ \psi_{n\mathbf{k}}=\psi_{n(\mathbf{k+K})} }[/math]. Therefore, all distinct Bloch waves occur for values of [math]\displaystyle{ \mathbf{k} }[/math] which fall within the first Brillouin zone of the reciprocal lattice.
  • 3.6K
  • 30 Nov 2022
Topic Review
Ion-Mobility Spectrometry
Ion mobility spectrometry (IMS) is an analytical technique used to separate and identify ionized molecules in the gas phase based on their mobility in a carrier buffer gas. Though heavily employed for military or security purposes, such as detecting drugs and explosives, the technique also has many laboratory analytical applications, including the analysis of both small and large biomolecules. IMS instruments are extremely sensitive stand-alone devices, but are often coupled with mass spectrometry, gas chromatography or high-performance liquid chromatography in order to achieve a multi-dimensional separation. They come in various sizes, ranging from a few millimeters to several meters depending on the specific application, and are capable of operating under a broad range of conditions. IMS instruments such as microscale high-field asymmetric-waveform ion-mobility spectrometry can be palm-portable for use in a range of applications including volatile organic compound (VOC) monitoring, biological sample analysis, medical diagnosis and food quality monitoring. Systems operated at higher pressure (i.e. atmospheric conditions, 1 atm or 1013 hPa) are often accompanied by elevated temperature (above 100 °C), while lower pressure systems (1-20 hPa) do not require heating.
  • 492
  • 30 Nov 2022
  • Page
  • of
  • 118
Video Production Service