Topic Review
Wearable Point-of-Care Devices
Personalized point-of-care testing (POCT) devices, such as wearable sensors, enable quick access to health monitoring without the use of complex instruments. Wearable sensors are gaining popularity owing to their ability to offer regular and continuous monitoring of physiological data by dynamic, non-invasive assessments of biomarkers in biofluids such as tear, sweat, interstitial fluid and saliva. 
  • 728
  • 09 May 2023
Topic Review
Wearable Piezoresistive, Inertial Sensors, RRM
The demand for wearable devices to measure respiratory activity is constantly growing, finding applications in a wide range of scenarios (e.g., clinical environments and workplaces, outdoors for monitoring sports activities, etc.). Particularly, the respiration rate (RR) is a vital parameter since it indicates serious illness (e.g., pneumonia, emphysema, pulmonary embolism, etc.). Therefore, several solutions have been presented in the scientific literature and on the market to make RR monitoring simple, accurate, reliable and noninvasive.
  • 715
  • 17 Sep 2021
Topic Review
Wearable Energy Harvesters
A rapidly expanding global population and a sizeable portion of it that is aging are the main causes of the significant increase in healthcare costs. Healthcare in terms of monitoring systems is undergoing radical changes, making it possible to gauge or monitor the health conditions of people constantly, while also removing some minor possibilities of going to the hospital. The development of automated devices that are either attached to organs or the skin, continually monitoring human activity, has been made feasible by advancements in sensor technologies, embedded systems, wireless communication technologies, nanotechnologies, and miniaturization being ultra-thin, lightweight, highly flexible, and stretchable. Wearable sensors track physiological signs together with other symptoms such as respiration, pulse, and gait pattern, etc., to spot unusual or unexpected events.
  • 246
  • 26 Jul 2023
Topic Review
Wearable Bluetooth Triage Healthcare Monitoring System
Triage is the first interaction between a patient and a nurse/paramedic. This assessment, usually performed at Emergency departments, is a highly dynamic process and there are international grading systems that according to the patient condition initiate the patient journey. Triage requires an initial rapid assessment followed by routine checks of the patients’ vitals, including respiratory rate, temperature, and pulse rate. Ideally, these checks should be performed continuously and remotely to reduce the workload on triage nurses; optimizing tools and monitoring systems can be introduced and include a wearable patient monitoring system that is not at the expense of the patient’s comfort and can be remotely monitored through wireless connectivity.
  • 539
  • 14 Apr 2022
Topic Review
Wearable Biosensors
Recent advances in lab-on-a-chip technology establish solid foundations for wearable biosensors. These newly emerging wearable biosensors are capable of non-invasive, continuous monitoring by miniaturization of electronics and integration with microfluidics. The advent of flexible electronics, biochemical sensors, soft microfluidics, and pain-free microneedles have created new generations of wearable biosensors that explore brand-new avenues to interface with the human epidermis for monitoring physiological status. However, these devices are relatively underexplored for sports monitoring and analytics, which may be largely facilitated by the recent emergence of wearable biosensors characterized by real-time, non-invasive, and non-irritating sensing capacities.
  • 2.0K
  • 18 Jan 2021
Topic Review
WD Repeat Domain 5 Inhibitors for Cancer Therapy
WDR5 is a conserved nuclear protein that scaffolds the assembly of epigenetic regulatory complexes and moonlights in functions ranging from recruiting MYC oncoproteins to chromatin to facilitating the integrity of mitosis. It is also a high-value target for anti-cancer therapies, with small molecule WDR5 inhibitors and degraders undergoing extensive preclinical assessment. WDR5 inhibitors were originally conceived as epigenetic modulators, proposed to inhibit cancer cells by reversing oncogenic patterns of histone H3 lysine 4 methylation—a notion that persists to this day.
  • 155
  • 15 Jan 2024
Topic Review
WBC and HBOT in Depression
Treatment with antidepressants is often insufficiently effective, especially in treatment-resistant depression. In such a situation, it is possible to change the drug, add a second antidepressant, or use pharmacological and non-pharmacological methods of augmenting the effect of pharmacotherapy. New methods that may fall into the scope of multi-module depression treatment as an augmentation of depression treatment are whole body cryotherapy (WBC) and hyperbaric oxygen treatment (HBOT). 545 records were selected and analyzed for these two treatments and finally three clinical trials were selected for analysis. 
  • 551
  • 22 Sep 2021
Topic Review
Wavefront Sensors and Aberration Sensors in Ophthalmology
The wavefront sensor is one of the main elements of the adaptive vision correction system. Its task is to measure the aberrations of the wavefront and transmit the results of these measurements to the processing device. The main causes of wavefront aberrations in the eye are the shape and optical properties of the cornea, pupil and lens. In modern diagnostic devices, wave aberrations are described in terms of Zernike polynomials (OSA and ANSI standards). Nowadays, there are a wide variety of wavefront sensors.
  • 152
  • 02 Jan 2024
Topic Review
Water Intoxication
Water intoxication, also known as water poisoning, hyperhydration, overhydration, or water toxemia, is a potentially fatal disturbance in brain functions that results when the normal balance of electrolytes in the body is pushed outside safe limits by excessive water intake. Under normal circumstances, accidentally consuming too much water is exceptionally rare. Nearly all deaths related to water intoxication in normal individuals have resulted either from water-drinking contests, in which individuals attempt to consume large amounts of water, or from long bouts of exercise during which excessive amounts of fluid were consumed. In addition, water cure, a method of torture in which the victim is forced to consume excessive amounts of water, can cause water intoxication. Water, just like any other substance, can be considered a poison when over-consumed in a brief period of time. Water intoxication mostly occurs when water is being consumed in a high quantity without adequate electrolyte intake. Excess of body water may also be a result of a medical condition or improper treatment; see "hyponatremia" for some examples. Water is considered one of the least toxic chemical compounds, with an LD50 of over 150 ml/kg in rats.
  • 400
  • 07 Nov 2022
Topic Review
Water Drinking Behavior Associated with Aversive Arousal
Cholinergic muscarinic stimulation of vast areas of the limbic brain induced a well-documented polydipsia in laboratory rats. This excessive water-drinking behavior has not received any convincing biological and physiological interpretation. The ascending cholinergic system originates from the laterodorsal tegmental nucleus, has a diffuse nature, and affects numerous subcortical limbic structures. It is proposed that the carbachol-induced drinking response is related to the state of anxiety and does not serve the regulation of thirst. Instead, the response is anxiety-induced polydipsia that might occur as a soothing procedure that decreases the aversiveness of the negative emotional state induced by carbachol. It is concluded that carbachol-induced water-drinking behavior is a rewarding process that contributes to alleviating the feeling of anxiety by bringing some relief from the cholinergically induced aversive state, and it is a homologue to anxiety-driven polydipsia in humans.
  • 438
  • 13 Jan 2023
  • Page
  • of
  • 1352