Summary

Analytical chemistry explores the principles, methods, and instruments used to separate, identify, and quantify chemical species in complex samples. This collection covers key topics such as chromatographic separation, mass spectrometry, optical and elemental spectrometry, ionization and detection strategies, and hyphenated analytical workflows. It also highlights applications of analytical chemistry in pharmaceuticals, environmental monitoring, clinical diagnostics, food safety, materials characterization, and industrial quality control, showcasing advances in sensitivity, selectivity, throughput, and data reliability that support scientific research and practical decision-making.

Expand All
Entries
Topic Review
Imaging Mass Spectrometry
Spatially resolved mass spectra acquired point by point or in a microscope geometry, then reconstructed into ion-intensity maps, constitute imaging mass spectrometry (IMS). A focused ionization probe—most often a matrix-assisted laser desorption/ionization (MALDI) laser, but also secondary-ion or ambient laser-ablation electrospray sources—is rastered across a tissue section or other surface; at each coordinate the mass spectrum reports local molecular composition [1]. The resulting images are therefore chemical maps indexed by mass-to-charge ratio, not optical micrographs [2]. Conceptual boundaries exclude bulk mass spectrometry of homogenates, optical microscopy without mass analysis, and non-imaging MALDI of discrete spots that are not assembled into a spatial grid. Essential features are a spatially defined ionization event, registration of spectra to sample coordinates, and a mass analyzer whose resolving power and speed match the imaging experiment [3]. MALDI IMS in particular records intact proteins, peptides, lipids, and metabolites in situ as molecular snapshots of the specimen [4].
  • 16
  • 21 Oct 2026
Topic Review
Hydrophilic Interaction Chromatography
Polar solutes that partition into a water-enriched layer held on a hydrophilic stationary phase, while the bulk mobile phase is a water-miscible organic solvent rich in acetonitrile or another polar organic, define hydrophilic interaction chromatography (HILIC). Retention increases with solute hydrophilicity and decreases as the water content of the eluent rises, which is the inverse of reversed-phase behavior [1]. Stationary phases include underivatized silica, amide, zwitterionic, and other polar bonded phases; the mobile phase is typically an aqueous buffer mixed with a high fraction of organic solvent [2]. Electrostatic repulsion hydrophilic interaction chromatography (ERLIC) superimposes Coulombic repulsion on the HILIC partition so that charged solutes can be eluted isocratically [3]. Conceptual boundaries exclude normal-phase adsorption on dry silica with nonpolar eluents that lack a water-rich layer, and they exclude ion-exchange chromatography whose retention is purely electrostatic. Essential features are a hydrophilic surface, a water-containing but organic-rich eluent, and a retention order governed by hydrophilic partition, possibly modulated by ionic interactions [4].
  • 11
  • 21 Oct 2026
Topic Review
High-Temperature Liquid Chromatography
Column temperatures well above ambient, typically from about 60 °C to more than 150 °C, define high-temperature liquid chromatography (HTLC) as a distinct operating regime of liquid chromatography. Elevated temperature lowers mobile-phase viscosity and increases solute diffusivity, which reduces back-pressure and can improve mass-transfer kinetics, while simultaneously shifting retention and sometimes selectivity [1]. Water and hydro-organic mixtures become less polar as temperature rises, so temperature can be used as a programmed variable analogous to solvent strength [2]. Conceptual boundaries exclude ordinary HPLC near room temperature, gas chromatography, and supercritical-fluid chromatography, although HTLC may approach the latter in solvent properties. Essential features are a thermally stable stationary phase, a preheater that brings the eluent to column temperature, and an analyte that remains chemically intact on the chromatographic timescale [3]. Practice and theory of the technique treat temperature as a thermodynamic and kinetic parameter of the same adsorption or partition equilibria that operate at ambient temperature, not as a separate separation mechanism [4].
  • 8
  • 21 Oct 2026
Topic Review
Glow Discharge Mass Spectrometry
A low-pressure glow discharge that sputters and ionizes a solid sample, with subsequent mass analysis of the ions, constitutes glow discharge mass spectrometry (GD-MS). The discharge is typically a direct-current or radiofrequency plasma in argon; cathodic sputtering releases atoms from the specimen, and those atoms are ionized in the plasma by Penning and electron-impact processes [1]. The resulting elemental ions are extracted into a magnetic-sector or quadrupole mass analyzer, so that the spectrum reports elemental and isotopic composition of the solid rather than a molecular fragmentation pattern [2]. Atmospheric-pressure glow-discharge and flowing-afterglow variants ionize vapors or thermally desorbed organics at higher pressure and are related ionization sources rather than the classical solids GD-MS experiment [3]. Conceptual boundaries exclude inductively coupled plasma mass spectrometry of solutions, spark-source mass spectrometry, and optical glow-discharge emission spectrometry that does not mass-analyze ions. Essential features are a glow-discharge ion source, a conducting or radiofrequency-coupled sample, and a mass analyzer that records the sputtered ions.
  • 10
  • 21 Oct 2026
Topic Review
Gas-Solid Chromatography
Adsorption of vapors on a solid adsorbent, with a gas as the only mobile phase, defines gas–solid chromatography (GSC). Unlike gas–liquid chromatography, there is no liquid stationary film; retention is governed by the adsorption isotherm of the solute on carbon, molecular sieves, porous polymers, or inorganic oxides [1]. The same experiment that separates permanent gases and light hydrocarbons also yields adsorption isotherms and surface-energy parameters when the solid is the object of study [2]. Conceptual boundaries exclude gas–liquid (partition) chromatography, inverse gas chromatography when it is used solely as a surface-characterization tool without being identified as GSC, and liquid–solid chromatography. Essential features are a gaseous carrier, a solid adsorbent packing or porous-layer wall, and a temperature at which the solutes remain volatile while adsorption remains reversible. Retention of carbon monoxide, light hydrocarbons, and related gases in packed or multi-bed adsorbent columns follows adsorption rather than partition into a liquid film [3].
  • 13
  • 21 Oct 2026
Topic Review
Frontal Chromatography
Continuous introduction of the sample feed, rather than a discrete injection pulse, defines frontal chromatography. As the feed enters the bed, the least-retained solute breaks through first as a sigmoidal front; more strongly retained solutes form later fronts, and the plateau concentrations and front positions report isotherms, binding capacities, and competitive adsorption [1]. In process chromatography the same frontal mode is used to pass a product while more strongly bound impurities (for example antibody aggregates) are retained, which is still frontal analysis rather than elution or displacement [2]. Conceptual boundaries exclude elution chromatography, in which a narrow feed band is developed by a weaker eluent, and displacement chromatography, in which a separate displacer forms an isotachic train. Essential features are uninterrupted feed, a stationary phase that is progressively saturated, and a breakthrough curve whose shape is governed by isotherm nonlinearity and axial dispersion [3]. Counter-current and membrane implementations retain the same frontal mass-balance structure while changing only the contacting geometry [4].
  • 7
  • 21 Oct 2026
Topic Review
Fourier Transform Mass Spectrometry
Time-domain image-current or related ion signals that are converted by Fourier transformation into a frequency-domain mass spectrum constitute Fourier transform mass spectrometry (FTMS). The frequency of ion motion—cyclotron frequency in an ICR cell or axial oscillation frequency in an electrostatic (Orbitrap) trap—is a precise function of mass-to-charge ratio, so that long, coherent transients yield high resolving power [1]. Space charge shifts those frequencies and must be accounted for in mass calibration [2]. Collisional or electron-based activation of trapped multiply charged ions can be performed inside the same analyzer, linking the FTMS measurement to tandem structural analysis [3]. Conceptual boundaries exclude scanning beam instruments (magnetic sector, quadrupole) and time-of-flight analyzers that do not record a Fourier-transformed transient, and they include both FT-ICR and Orbitrap implementations as members of the FTMS class [4]. Essential features are ion trapping that supports periodic motion, broadband detection of that motion, and a Fourier-transform conversion from time to mass-to-charge ratio.
  • 11
  • 21 Oct 2026
Topic Review
FT-ICR Mass Spectrometry
Ion cyclotron motion in a strong magnetic field, recorded as an image-current transient and converted by Fourier transformation into a frequency-domain mass spectrum, defines Fourier-transform ion-cyclotron-resonance (FT-ICR) mass spectrometry. Trapped ions orbit at a cyclotron frequency inversely proportional to their mass-to-charge ratio; broadband excitation and detection of that motion yield ultra-high mass resolving power and mass accuracy [1]. The same trapped-ion population can be activated by collisions or by electron capture, so that tandem spectra report connectivity without leaving the ICR cell [2]. Conceptual boundaries exclude quadrupole, time-of-flight, and Orbitrap Fourier-transform instruments that do not use cyclotron motion in a homogeneous magnet, although all Fourier-transform mass spectrometers share the time-to-frequency conversion step. Essential features are a high-field magnet, an ion trap that supports coherent cyclotron motion, and a Fourier-transform data system. Exact-composition assignment in complex mixtures and localization of noncovalent ligand sites are analytical consequences of the mass accuracy and tandem capabilities inherent in the ICR measurement principle [3]. An FT-ICR spectrum of dissolved organic matter is correspondingly interpreted as a catalogue of exact molecular compositions rather than as a chromatographic retention map [4].
  • 7
  • 21 Oct 2026
Topic Review
Electrochromatography
An electric field superimposed on a chromatographic bed, so that electroosmotic flow and electrophoretic migration act together with chromatographic retention, defines electrochromatography, most often implemented as capillary electrochromatography (CEC). The stationary phase may be a packed bed, a surface-grafted open tube, or an in situ formed porous monolith; the mobile phase is driven primarily by electroosmosis rather than by a pressure drop [1]. Rigid polymer monoliths allow independent control of pore structure and surface chemistry, which in turn set permeability, electroosmotic mobility, and chromatographic selectivity [2]. Conceptual boundaries exclude pressure-driven micro-HPLC in the same capillary, and they exclude free-zone capillary electrophoresis that lacks a stationary phase. Essential features are a charged or chargeable surface that supports electroosmosis, a stationary phase that partitions or adsorbs the solutes, and an applied voltage that generates the flow [3]. Monolithic and bead-trapping formats extend the same electrochromatographic principle from fused-silica capillaries to microfluidic channels [4].
  • 12
  • 21 Oct 2026
Topic Review
Displacement Chromatography
A more strongly retained displacer that advances as a sharp front and competitively desorbs weaker solutes defines displacement chromatography. After the feed is loaded, a displacer solution is introduced; solutes leave the column as adjacent, high-concentration isotachic bands ordered by binding affinity, rather than as diluted Gaussian peaks produced by an eluent that is weaker than the solutes [1]. On synthetic ion-exchange resins, amino acids form ordered displacement zones according to competitive binding strength; this differs from frontal analysis, in which the sample itself is the only feed [2]. Cation-exchange displacement of differently charged proteins confirms that the defining element is the displacer-driven band train rather than a particular adsorbent chemistry [3]. Essential features are a displacer whose affinity exceeds that of all targets, a loading high enough to enter the nonlinear isotherm region, and a regeneration step that removes the displacer. Conceptual boundaries exclude gradient elution, in which solvent strength, not a displacer front, releases the solutes [4].
  • 5
  • 21 Oct 2026