Summary

Analytical chemistry explores the principles, methods, and instruments used to separate, identify, and quantify chemical species in complex samples. This collection covers key topics such as chromatographic separation, mass spectrometry, optical and elemental spectrometry, ionization and detection strategies, and hyphenated analytical workflows. It also highlights applications of analytical chemistry in pharmaceuticals, environmental monitoring, clinical diagnostics, food safety, materials characterization, and industrial quality control, showcasing advances in sensitivity, selectivity, throughput, and data reliability that support scientific research and practical decision-making.

Expand All
Entries
Topic Review
Laser Microprobe Mass Spectrometry
A focused laser that ablates a micrometre-scale spot, coupled to a time-of-flight or related mass analyzer, defines laser microprobe mass spectrometry (LMMS, historically LAMMA). The microprobe geometry localizes the desorption and ionization event so that elemental and molecular ions from a selected microscopic volume are recorded [1]. Direct laser desorption from the neat solid may be compared with matrix-assisted desorption from the same microprobe, which changes the ion yield and fragmentation but not the spatial-probe definition [2]. Conceptual boundaries exclude bulk laser-desorption mass spectrometry without spatial selection, secondary-ion microprobes that use an ion beam, and optical laser microprobes that do not mass-analyze the ejecta. Essential features are a diffraction-limited or otherwise focused laser, a viewing system that registers the sampled spot, and a mass analyzer synchronized to the laser pulse [3]. Inorganic deposits and organometallic drugs in tissue have been identified by the same localized ionization, which underscores that the defining object is the microprobe-sampled mass spectrum [4].
  • 16
  • 21 Oct 2026
Topic Review
Laser Desorption Mass Spectrometry
Laser desorption mass spectrometry uses a pulsed laser to release material from a condensed-phase sample and generate gas-phase ions for mass analysis. In direct laser desorption, the analyte or substrate absorbs the pulse; in matrix-assisted laser desorption/ionization (MALDI), an excess of a light-absorbing matrix co-crystallized with the analyte mediates energy deposition and ion formation [1]. Short irradiation produces a desorption plume containing neutrals, clusters, and ions, and subsequent proton-transfer, cationization, or deprotonation processes determine the detected species. The source is commonly coupled to a time-of-flight analyzer because pulsed ion production provides a natural start time, but the analyzer is not part of the defining ionization principle [2]. The method differs from electrospray, which forms ions from charged droplets, and from secondary-ion mass spectrometry, which uses a primary ion beam. Its essential features are pulsed photon irradiation, a localized condensed sample, desorption with ion formation, extraction of the plume ions, and mass-to-charge measurement.
  • 20
  • 21 Oct 2026
Topic Review
Isotope Ratio Mass Spectrometry
Precise measurement of the relative abundances of stable isotopes of an element, typically as simple gases admitted to a magnetic-sector instrument, defines isotope ratio mass spectrometry (IRMS). Dual-inlet or continuous-flow sources ionize CO2, N2, H2, SO2, or related gases; Faraday cups simultaneously collect the isotopologues, and the ratio is reported on an international delta scale relative to a standard [1]. Hyphenation to gas or liquid chromatography (GC/C/IRMS, LC-IRMS) converts each eluting compound to a simple gas before the ratio measurement, so that compound-specific isotope ratios are obtained [2]. Conceptual boundaries exclude organic molecular mass spectrometry that reports nominal or exact masses of intact molecules, accelerator mass spectrometry of rare radionuclides, and optical isotope-ratio methods. Essential features are simultaneous or rapidly switched collection of two or more isotopic ion beams, high-precision electronics, and a calibration to certified isotopic reference materials [3]. Compound-specific measurements of steroids retain the same defining observable: a calibrated isotope-abundance ratio for an element in the isolated compound [4].
  • 10
  • 21 Oct 2026
Topic Review
Ionization Spectrometry
Conversion of neutral atoms or molecules into ions, followed by optical or mass-spectrometric readout of those ions, is the defining sequence of ionization spectrometry. In laser-enhanced ionization and resonant ionization, tuned lasers promote atoms to excited states that are more readily ionized in a flame or vacuum, and the resulting ions or the ionization current are measured [1]. Laser desorption coupled to resonant ionization separates the desorption event from a subsequent wavelength-selective ionization step [2]. Surface-enhanced laser desorption/ionization records ions generated at a chemically modified surface, which is a desorption-ionization variant of the same ion-production concept [3]. Conceptual boundaries exclude purely photonic absorption or emission spectrometry that does not produce ions, and they exclude mass spectrometry named only by its analyzer when the ionization step is not the defining object. Essential features are a defined ionization mechanism, a population of ions whose number or mass-to-charge ratio is the analytical signal, and an optical or mass-selective observation of that population [4].
  • 6
  • 21 Oct 2026
Topic Review
Ion Trap Spectrometry
Radiofrequency electric fields that confine ions in a three-dimensional or linear quadrupole trap, with subsequent mass-selective ejection or isolation, define ion-trap spectrometry. Ions of a chosen mass-to-charge window are stored, optionally fragmented by resonant excitation or ion–molecule reactions, and then scanned out to a detector, so that the trap is both an ion store and a mass analyzer [1]. Quadrupole ion traps coupled to gas or liquid chromatography therefore provide tandem mass spectra from a single analyzer rather than from a beam-type collision cell [2]. Conceptual boundaries exclude magnetic-sector, time-of-flight, and Fourier-transform ICR analyzers, and they exclude ion-mobility spectrometry that separates ions by collision cross section in a drift gas without RF trapping as the mass-analysis principle. Essential features are an RF trapping potential, a means of mass-selective instability or resonance ejection, and, for tandem work, a controlled activation step inside the trap [3]. The recorded observable remains the mass-to-charge ratio of precursor and product ions.
  • 11
  • 21 Oct 2026
Topic Review
Ion Exchange Chromatography
Reversible electrostatic binding of charged solutes to an oppositely charged immobilized exchanger, followed by elution with a competing ion or a pH change, defines ion-exchange chromatography (IEX). Cation exchangers carry sulfonate or carboxylate groups; anion exchangers carry quaternary ammonium or diethylaminoethyl groups; both may be realized on resins, celluloses, silicas, or thin layers [1]. Retention is a function of the solute’s net charge, the exchanger’s capacity and pKa, and the ionic strength and pH of the buffer [2]. Modern IEX of biopharmaceuticals uses high-resolution particle and monolith formats to resolve charge variants of proteins, which remains the same electrostatic mechanism [3]. Conceptual boundaries exclude reversed-phase and hydrophilic-interaction chromatography, affinity chromatography, and electrophoretic separations that lack a chromatographic exchanger. Essential features are a defined ionogenic ligand, a buffered aqueous mobile phase, and a salt or pH program that displaces bound ions. Urea and related additives may modulate secondary (non-ionic) contacts without changing the primary ion-exchange definition [4].
  • 15
  • 21 Oct 2026
Topic Review
Ion Chromatography
High-performance ion-exchange separation of small inorganic and organic ions, usually with suppressed or non-suppressed conductivity detection, constitutes ion chromatography (IC) in analytical chemistry. A low-capacity ion-exchange column is eluted with a dilute aqueous eluent; after chemical or electrolytic suppression of the eluent’s background conductivity, the analyte ions are recorded as conductivity peaks, although UV, amperometric, or mass-spectrometric detection may be used instead [1]. Combustion ion chromatography converts organically bound fluorine or other heteroatoms to inorganic ions before the chromatographic step, which is still IC of those ions [2]. Conceptual boundaries exclude gas-phase ion mobility sometimes also called ion chromatography, and they exclude general ion-exchange chromatography of proteins that is not configured as high-performance IC of small ions. Essential features are an ion-exchange separator, an eluent whose strength is matched to monovalent and divalent ions, and a detection scheme that reports ionic equivalents. Silver-ion chromatography of lipids is a related but distinct complexation mode and is not IC in the suppressed-conductivity sense [3].
  • 6
  • 21 Oct 2026
Topic Review
Inverse Gas Chromatography
The packing, not the injected probes, is the object of study in inverse gas chromatography (IGC). Known volatile probes are pulsed or flowed through a column filled with the solid, polymer, or powder of interest; their retention volumes, peak shapes, and temperature dependence report surface energy, acid–base parameters, solubility parameters, and porosity of that packing [1]. In the infinite-dilution limit, retention is governed by probe–surface interactions at vanishing coverage; at finite concentration the same experiment yields adsorption isotherms [2]. Conceptual boundaries exclude ordinary gas chromatography, in which the sample is unknown and the column is a calibrated separating medium, and they exclude inverse liquid chromatography. Essential features are a well-characterized probe set, a defined temperature and carrier-gas flow, and a data reduction that converts retention into physicochemical descriptors of the stationary material [3]. Surface-energy measurements of powders and crystalline polymorphs confirm that an inverse-gas chromatogram is interpreted as a property of the solid rather than as identification of the probe vapor [4].
  • 12
  • 21 Oct 2026
Topic Review
Interaction Chromatography
Retention governed by a specified class of noncovalent contacts between the solute and a complementary stationary phase, rather than by size exclusion alone, is the conceptual core of interaction chromatography. In analytical practice the term groups hydrophilic-interaction, electrostatic, and related modes in which polar or charged solutes partition into or bind to a water-rich or ionizable layer on the packing [1]. Hydrophilic interaction chromatography is the most fully articulated member of this family: a polar bonded phase operated with an organic-rich, water-containing eluent retains polar peptides, nucleic acids, and metabolites in order of increasing hydrophilicity [2]. Electrostatic repulsion can be superimposed on that hydrophilic partition so that charged solutes elute isocratically while still experiencing the interaction layer [3]. Conceptual boundaries exclude gel permeation and other purely steric exclusions, and they exclude biospecific affinity chromatography, whose ligand is a molecular recognition partner rather than a generic interaction surface. Essential features are a defined interaction chemistry, a mobile phase that modulates that interaction, and a retention order that reports the interaction rather than hydrodynamic volume [4].
  • 3
  • 21 Oct 2026
Topic Review
Immunoaffinity Chromatography
Immunoaffinity chromatography is a form of liquid affinity chromatography in which an antibody, antibody fragment, antigen, or closely related immunoreagent serves as the immobilized recognition ligand. A complementary target binds through reversible antigen–antibody recognition while nonbinding components pass through or are removed by washing [1]. The captured species is released by conditions that weaken noncovalent binding, such as controlled changes in pH or ionic strength or addition of a competing epitope, without cleaving the immobilization linkage. Selectivity depends on antibody affinity and cross-reactivity, ligand orientation and surface density, support accessibility, and mass transfer [2]. The method is a chromatographic bed or flow-through device and is therefore distinct from immunoprecipitation in a freely suspended solid phase. It is also narrower than general affinity chromatography because the recognition pair is immunological. Essential features are an immobilized immunoreagent, reversible and specific target capture, washing that preserves the complex, and an elution or detection step that reports the retained target.
  • 14
  • 21 Oct 2026