CTs are among the most common procedure performed in many tertiary eye centers worldwide
[5][6][7][8][9][10][11][12]. Various forms of CT are carried out, depending on the laminar depth of scarring or recipient corneal tissue viability. Lamellar keratoplasty is indicated when scarring extends to the corneal epithelium, Bowman’s layer, and stroma. This can either be anterior lamellar keratoplasty (ALK) for more superficial graft implantation; or deep lamellar keratoplasty (DLK)
[13] when the stroma is equally diseased. The technique of penetrating keratoplasty (PK) replaces the entire thickness of corneal tissue
[14]. The advent of endothelial keratoplasty (EK) has evolved the surgical approach to corneal endothelial dystrophies (i.e., Fuch’s endothelial dystrophy (FED), congenital hereditary endothelial dystrophy), and other corneal insults causing endothelial pump failure. EK is performed via various techniques, including Descemet’s stripping endothelial keratoplasty (DSEK), Descemet’s membrane endothelial keratoplasty (DMEK), Descemet’s membrane automated endothelial keratoplasty (DMAEK), and posterior lamellar keratoplasty (PLK)
[15][16]. Usually, for lamellar keratoplasty and penetrating keratoplasty, donor corneal tissue is secured to recipient corneal tissue via peripheral sutures. Meanwhile, endothelial keratoplasty (EK) has evolved to the use of appositional intracameral gas bubbles and ophthalmic viscoelastic solution.
When significant corneal stromal haze or widespread leucomatous scarring impairs intraocular evaluation, imaging modalities such as anterior segment-ocular coherence tomography (AS-OCT), ultrasound biomicroscopy (UBM), and B scan ultrasonography can be respectively utilized to gain a gross outline of individualized intraocular integrity. Corneal central thickness (CCT) measurements with pachymetry have, in the past, been correlated with corneal endothelial cell (CEC) loss
[19], mostly among contact lens wearers and pseudophakic individuals
[20]; hence, it may be an empirical indicator of viable host endothelial physiology prior to lamellar keratoplasty
[21]. The patient’s innate or adaptive immune status plays a fundamental role in CT outcomes, especially in terms of the risk of post-graft rejection
[22].
7. Preparation and Storage of Donor Corneas
Corneal donation involves identifying a potential donor eye, preparing the eye for removal of the graft, extraction of donor tissue and storage. Therefore, the preparation of corneal grafts takes up a critical stage in this regard due to the high demand for cornea tissue and relatively lower supply
[47][48]. Intra-operative optical coherence tomography has been useful in the preparations of corneal tissue during extraction. Donor tissue preparation can also be done under this new technology
[49]. This technique showed a remarkable 98.5% match with other standard clinical grading. Specular spectroscopy can be used to evaluate endothelial cell density. Modis et al. suggested that specular and non-specular spectroscopy can be used as exchangeable
[50]. Bonci et al. compared two methods of preparation of donor corneas; one method used a Hanna trephine with an external chamber, while the other used the same Hanna trephine but with a punch
[51]. The methods extracted the donor cornea along the epithelium-endothelium and endothelium-epithelium directions, respectively. The study revealed that endothelial cell density (ECD) loss was less in the epithelium-endothelium cut corneas. As ophthalmic surgeons are ultimately responsible for carrying out these procedures, it is imperative that they keep abreast with different developments in the field by retraining and reviewing relevant literature.
Hagenah and Winter reviewed recent trends in globe disinfection before graft extraction
[52]. They suggested a 3% povidone-iodine solution for disinfecting the globes. It is also advised that extracted corneal tissue should be secured in a corneoscleral disc for some time to antibiotics neutralize any remaining contaminants. They recommended that storage containers can be sealed or changed every two weeks under aseptic conditions
[52]. Wykrota et al. examined activities at an Eye bank over a period of nine years and reported that low endothelial cell count (ECC) was the most common reason for discarding banked corneas, followed by tissue contamination
[53]. Solley et al. reported a new device for preparing grafts via Descemet membrane endothelial keratoplasty in diabetic and non-diabetic eyes. This new device, the DescePrep, performed well with a 97% success rate and average cell death post-extraction at 7.9% ± 3.7% for all corneas
[54].
The ECD can be a very important indicator of the eventual viability of the graft. Gupta and Gupta examined 100 eyes that received corneal transplants within a two-year period over periodic intervals. They reported that the most endothelial cell loss was seen in patients undergoing a repeat graft, while keratoconus-grafted eyes showed the lowest loss
[55]. Another study found that while ECD was not related to endothelial decompensation after transplant, it was positively r = correlated with the same at six months post-operation
[56]. This study also reported a drop in ECD to lower than 500 cells/mm
2 in 14% of its participants and co-morbidities in corneal transplant medicine.
This relative scarcity of corneas for transplant puts their storage on the front burner for many researchers. The numbers of overall grafts properly stored and the eventual viability of the grafts when needed for eventual transplant are two key indices that can advise on the progress of corneal tissue storage development. Garcin et al. developed an active storage device which they called a bioreactor and compared its preservation abilities versus the organ culture storage technique. They published results showing that the bioreactor had a 23% higher rate of endothelial cell survival than the organ culture technique
[57]. They also reported better transparency and tissue integrity in the corneas stored using the bioreactor as compared to the organ culture technique. The authors also showed increased longevity of tissue preservation by using active storage. They conducted a random trial using 24 paired corneas equally split between organ culture and their active storage machine. Their study showed that the active storage system maintained tissue integrity, endothelial cell viability, and numbers in addition to the expression of biochemical stability markers like CD166. In contrast, the organ culture-stored corneas were all found to be unsuitable for corneal transplant at the same time period
[58].
Generally, the causes of CT failure have been classified into:
The cornea endothelium is an inner barrier to edematous damage from aqueous humor breaching into the cornea. Endothelial cell count (CEC) is therefore essential to assess the ability of the eye to retain this protective ability. Studies have shown that the CEC is significantly reduced when corneas are extracted for grafting
[64]. Jafarinasab et al. reported on the outcomes of CT in 32 eyes that had previously suffered globe rupture. They reported a progressive reduction in stability in the host-graft interface. They also suggested that an uncompromised Descemet’s membrane layer can help to mitigate this occurrence
[65]. This Endothelium/Descemet complex thickness (En/DMT) is a good indicator of the prognosis of stability after a successful CT. In fact, an increased En/DMT thickness is an indicator of tissue rejection post-CT, especially in high-risk corneas
[66].
Cytokine elevation has also been observed in eyes that suffered CT failure
[67], although topical postoperative drugs like levofloxacin, Fk506 and dexamethasone had no deleterious effect when used post-PKP
[68][69]. Any disruption in the normal homeostatic and tissue balance in the cornea can first result in corneal haze (CH)
[69]. Pentacam Scheimpflug densitometry was used to measure CH in 44 and an incidence of 6.8% (95%CI: 1.4–18.7%) in a tertiary hospital-based study
[70]. Corneal densitometry measured 21.86 ± 6.22 GSU preoperatively in the 44 eyes. However, this reduced to 21.23 ± 4.29 GSU at 12 months postoperatively (
p = 0.815).
Wound dehiscence is a common complication post-CT. A study was conducted in the Riyal Eye and Ear hospital to assess the incidence and clinical demographic of 72 eyes who visited a center for surgery
[71]. Perioperative wound dehiscence may also occur at the host-graft junction and lead to a failure of the CT
[72]. The presence of lymphatic vessels within neovascularized failed CT has also been implicated. It remains to be determined if this suggests a new direction for future preventive management
[73]. Fine needle diathermy has been indicated as a novel method of managing this lymphangiogenesis
[74].
Corneal opacities impede intraoperative visualization during cataract extraction and vitreoretinal surgery
[75]. Performing keratoplasty prior to other secondary intraocular surgeries, however, may risk graft tissue viability. Hence, bi-procedural approaches have been explored. Combined keratoplasty and pars plana vitrectomy (PPV) has been successfully performed. The study reported, however, high rates of graft failure, which were correlated with active intraoperative corneal inflammation
[76]. Planned EK following cataract surgery has also been recommended amongst patients with endothelial dysfunctions: dystrophic, degenerative or secondary to ocular disease like glaucoma
[75]. Features consistent with the ocular dysgenesis disorder, aniridia, have been shown to manifest onto donor corneal buttons following transplantation to diseased corneas
[77].
Clinicians should also note that patients receiving immune checkpoint medication are at risk of CT rejection
[78]. Common systemic conditions like diabetes can encourage infection and delay wound healing. Infective agents/diseases have also been implicated as sources of poor outcomes. Donors may be the source of infective pathogens that eventually lead to a CT rejection in the future. A Saudi Arabia study found that 0.88% of donated corneas used in 684 CT cases were positive for infective pathogens
[79]. Candida infections are commonly reported as culprits in CT failure
[80]. In a review of 789 eyes that underwent CT at two Indian centers, five eyes (0.63%) developed complications secondary to Candida infections. Contributing risk factors were prolonged steroid use, repeated CT, and cornea epithelial weakness
[81].
Another study at a different center reported an incidence of microbial keratitis in 4.77% of 1508 eyes that had undergone CT
[82]. Natamycin and voriconazole have been suggested as viable therapeutic regimens for managing Candida infections
[83]. Mucormycosis has been registered post-deep-anterior-lamellar-keratoplasty (DALK)
[84], with a suggestion to manage any sinusitis in a diabetic patient before attempting CT surgery. Giurgola et al. have suggested that Kerasave, a new synthetic product, may drastically reduce in-vitro contamination of donor corneas
[85]. Animal models have also indicated that injection of mesenchymal stem cells may limit acute post-CT inflammation
[86].
Non-infective unforeseen events can also complicate the CT process. Jarstad et al. reported a case of cardiac failure in an otherwise healthy young adult during CT surgery that was successfully managed
[87]. Another common complication of CT is glaucoma
[88]. Management may include pharmacological agents or surgery. Studies have shown that surgery for glaucoma after CT has been implicated in CT rejection
[89].
Rare conditions like monoclonal gammopathy of undetermined significance are also implicated, especially in the presence of elevated levels of abnormal M proteins
[90]. Paniz-Mondolfi et al. also reported the isolation of Colletotrichum chlorophyti in an eye with postoperative endophthalmitis after CT
[91]. Another study reported a post-CT infection of Alternaria alternate
[92]. The human cytomegalovirus (CMV) is known to attack tissue all over the body. Like all viral conditions, it can lie dormant for extended periods and become active without warning. CMV endothelitis results in loss of CEC and subsequent poor prognosis.
As with any grafting procedure, immunologic interactions between the host and donor tissue can be problematic. However, non-immunologic factors can also be a factor in the loss of CEC, even with patients receiving autologous CT
[93]. Repeat transplant/graft procedures are also a risk factor in the failure of CT. Aboshisha et al. conducted a large-scale study to examine the survival rates for regraft procedures for keratoconus, Fuch’s endothelial dystrophy, and pseudophakic bullous keratopathy (PBK). PK and EK were the procedures of choice for FE dystrophy and PBK, while PK and DALK were the procedures of choice for keratoconus
[94]. Sometimes, the failure is not in the procedure nor the result but in the patient’s experiences after CT
[95]. Masmoudi et al. reported a patient suffering from Charles Bonnet syndrome after CT
[96].