Submitted Successfully!
To reward your contribution, here is a gift for you: A free trial for our video production service.
Thank you for your contribution! You can also upload a video entry or images related to this topic.
Version Summary Created by Modification Content Size Created at Operation
1 -- 1653 2023-03-22 19:01:10 |
2 format Meta information modification 1653 2023-03-23 02:28:18 |

Video Upload Options

Do you have a full video?

Confirm

Are you sure to Delete?
Cite
If you have any further questions, please contact Encyclopedia Editorial Office.
Prpic, V.; Catic, A.; Kraljevic Simunkovic, S.; Bergman, L.; Cimic, S. CAD/CAM Denture Base Materials. Encyclopedia. Available online: https://encyclopedia.pub/entry/42445 (accessed on 28 March 2024).
Prpic V, Catic A, Kraljevic Simunkovic S, Bergman L, Cimic S. CAD/CAM Denture Base Materials. Encyclopedia. Available at: https://encyclopedia.pub/entry/42445. Accessed March 28, 2024.
Prpic, Vladimir, Amir Catic, Sonja Kraljevic Simunkovic, Lana Bergman, Samir Cimic. "CAD/CAM Denture Base Materials" Encyclopedia, https://encyclopedia.pub/entry/42445 (accessed March 28, 2024).
Prpic, V., Catic, A., Kraljevic Simunkovic, S., Bergman, L., & Cimic, S. (2023, March 22). CAD/CAM Denture Base Materials. In Encyclopedia. https://encyclopedia.pub/entry/42445
Prpic, Vladimir, et al. "CAD/CAM Denture Base Materials." Encyclopedia. Web. 22 March, 2023.
CAD/CAM Denture Base Materials
Edit

The data about bond strength between digitally produced denture base resins and artificial teeth are scarce. No statistical differences between heat-polymerized and CAD/CAM (milled) denture base materials when attached with different types of artificial teeth, while one study showed higher values of CAD/CAM (milled) denture base materials. Bonding agents ensure bonding strength at least similar to the conventional methods. In order to improve the quality of future studies, it would be advantageous to use a larger number of specimens with standardized dimensions and a blinded testing machine operator to decrease the risk of bias.

dentures CAD/CAM artificial teeth

1. Introduction

Edentulism is defined as a complete absence of teeth and is considered a disability by the World Health Organization (WHO) [1]. The prevalence of reported causes for tooth loss is as follows: caries (36.0% to 55.3%); periodontitis (24.8% to 38.1%); trauma (0.8% to 4.4%), periapical disease (7.3% to 19.1%); orthodontics (2.5% to 7.2%); and other reasons (4.5% to 9.2%) [2]. Following tooth loss, the underlying bone continues to resorb, and there are changes to patients’ facial appearance and facial height [3]. Moreover, elderly people who wear complete dentures are more likely to experience denture stomatitis, an inflammatory condition of the palatal mucosa, as well as angular cheilitis, oral candidosis, and traumatic ulcers [3]. Dental health has a significant impact on quality of life; edentulism negatively affects patients’ quality of life because it decreases chewing capacity, enervates phonetics, and impairs aesthetics [4]. The loss of chewing efficacy can result in a decreased intake of food (e.g., vegetables and fruit), which could lead to malnutrition. Simultaneously, edentulous patients cannot meet dietary recommendations [5]. In addition, edentulism can be connected with several systematic conditions such as pneumonia, adiposity, neck and head carcinoma, and a higher risk of mortality [1]. Studies showed different prevalences of edentulism. Females have higher prevalence of edentulism when compared to males, especially females with poor profit and lower degree of education [6]. In a review, Polzer et al. [7] determined that the prevalence of edentulism ranges from 1.3% to 78% for people aged 65 and older. Inter- and intracountry differences in the prevalence of edentulism exist, but comparison between nations is challenging because of different factors (e.g., erudition, economical instance, dental health competence, and beliefs and attitudes towards oral health) which can influence the outcome [3][8]. Manifestations of edentulism are constantly falling in developed countries, whilst in developing countries, the opposite trend has been observed [9]. Nevertheless, a study by Douglass et al. [10] showed increasing edentulism as a result of aging and longer life expectancy. The higher number of elderly people could be caused by demographic changes which can be seen in the majority of countries [11]. A total of 703 million people worldwide are aged 65 years and above, and it is predicted that the given number will double by 2050.
Complete dentures have been used for many years and are considered the gold standard for treating patients with this condition [4][7][12][13][14]. Although other types of prosthodontic solutions for edentulism are accessible, such as implant-supported dentures, most patients decide to wear conventional ones, mainly because of financial causes [15][16][17]. Until today, polymethyl methacrylate (PMMA) has remained the most accepted denture base resin [18][19]. PMMA conforms to some of the requirements for a perfect denture base resin, which include easy mending, optimal appearance, and a tolerable price [13][20]. Common manipulation is also one of the advantages and is started by mixing methyl methacrylate (monomer) and polymethyl methacrylate (polymer) [18]. The polymerization process of a given type of PMMA (heat-polymerized resin) is terminated after a certain exposure time to heat. Despite all the advantages, polymerization shrinkage of 6% can be interpreted as the main disadvantage [18]. Moreover, the chemical reaction between methyl methacrylate and polymethyl methacrylate is never complete. Leftovers of the residual monomer after the polymerization process can modify the mechanical properties of the material and cause allergic reactions (e.g., oedema, stomatitis, and ulcerations) [18][21].
Bonding between the denture base material and the artificial teeth is imperative for completeness of dentures and patient’s quality of life. Resin artificial teeth are used more frequently when compared to porcelain ones because of the chemical bonding that occurs and simple occlusal adaptation [22]. Furthermore, resin denture teeth are persistent to thermal changes and are less pervious to fracture under impact [22].

2. Shear Bond Strength between Milled Denture Base Materials and Artificial Teeth

The effects of complete tooth loss can be minimized through rehabilitation with dental prostheses, which is the most cost-effective and most widely used treatment. Modifications in the orofacial muscles, combined with the necessary prosthodontic rehabilitation, repair impaired self-esteem and improve confidence by renewing the patient’s appearance [23].
Shear bond strength is the strength between two materials, and it shows how much each material resists the load before it fractures under a shear force [24][25]. Considering the fact that debonding can occur between denture base resins and an artificial tooth for different reasons, shear bond strength values should be as high as possible [24]. Generally, the shear bond strength test is standardly used for investigating the bond strength between denture base resin and artificial tooth resin [4][24][26][27][28][29]. Apart from the shear bond strength testing, some other testing procedures are available. Flexural bond strength (FBS) testing represents a novel method for the measurement of bond strength [30]. However, not enough studies have been conducted so far regarding flexural bond strength as a new testing modality [30]. Shear bond strength testing is most widely used because of its simplicity and ease of specimen preparation—no additional treatment of specimens is required after the bonding proceeding [31][32]. Considering the fact that the crosshead speed of the universal testing machine has an impact on shear bond strength values, the recommended crosshead speed is set between 0.45 and 1.05 mm/min [33], which all included studies accomplished.
The reported values of shear bond strength between denture base resins and artificial teeth vary [27][28][34][35][36][37]. This could be credited to the absence of standardization of testing methods as well as the variety of denture base materials available on the market [24]. The literature agrees that with different types of denture base materials (cold-polymerized, heat-polymerized, microwave-polymerized, light-polymerized, and others) differences in shear bond strength values to prefabricated denture teeth can be expected [27][35]. Studies also showed that different types/materials of prefabricated denture teeth can have different shear bond strengths with denture base resin. When comparing monomer diffusion between heat-polymerized denture base resin and different types of artificial teeth during the bonding procedure, it could be noted that the diffusion rate is higher in acrylic teeth in comparison with cross-linked and composite teeth [26]. Since acrylic teeth can chemically bond to heat-polymerized denture base resin via high monomer diffusion, high shear bond strength values are foreseen [24][38]. To achieve adequate chemical bonding, as with a milled denture base, different bonding agents are applied [24][39][40][41][42]. In a systematic review of bonding to CAD/CAM indirect resin materials, Mine et al. [42] concluded that the appliance of methyl methacrylate adhesives enhances the bonding of CAD/CAM (milled) materials.
A review of recent studies showed different results for the shear bond strength between CAD/CAM (milled) denture base resins and artificial teeth and control groups (heat-polymerized denture base resins and artificial teeth). In a study by Prpić et al. [24] and a study by Han et al. [26], shear bond strength values between (different) denture teeth and CAD/CAM (milled) denture base resin had comparable results to the same teeth connected with heat-polymerized denture base resin. Prpić et al. [24] compared the shear bond strength values of different types of artificial teeth (acrylic, nanohybrid composite, and cross-linked) attached to CAD/CAM (milled) denture base resin. Similarly, Han et al. [26] examined shear bond strength values between CAD/CAM (milled) denture base resins and composites with fillers and cross-linked teeth. Both studies used bonding agents for attaching teeth to milled denture base material and had a control group with heat-polymerized resin. Contrary to these studies by Prpić et al. [24] and Han et al. [26], Helal et al. [4] reported higher shear bond strength values between CAD/CAM (milled) denture base resin and two types of denture teeth (acrylic and composite) when compared to conventional heat-polymerized acrylics. This can be interpreted by the volumetric shrinkage reported in heat-polymerized acrylics, which could decrease shear bond strength values [4]. Still, the determined results of studies agree that the use of a bonding agent is at least comparable to the conventional method (compression moulding technique).
As follows from the previous paragraph, two studies [24][26] indicated that no statistical differences were observed between heat-polymerized and CAD/CAM (milled) denture base materials when attached to different types of artificial teeth, and one study showed higher values for CAD/CAM (milled) denture base materials [4]. Conventional hot water/bath polymerization represents the most effective and eligible procedure for denture fabrication as well as for bonding artificial teeth to denture base material [43]. Considering this fact, shear bond strength values between CAD/CAM (milled) denture base materials and denture teeth comparable to the conventional method can be considered a success. In other words, currently available bonding agents used to achieve optimal bonding between CAD/CAM (milled) denture base materials and artificial teeth demonstrate high shear bond strength values, equivalent to the bonding values between conventional denture base materials and artificial teeth [24].
Traditional fabrication techniques for removable dental prostheses are well known and are still frequently used in clinical practice today. These traditional complete denture protocols require multiple patient visits as well as extensive chairside and laboratory time [44]. Recent advancements have made it possible to incorporate computer-aided design and manufacturing (CAD/CAM) technologies into the complete denture manufacturing process. The constant evolution and improvement of technology has resulted in an exponential increase in the number of providers and systems available on the market today [44]. Some studies indicate that complete dentures produced using CAD/CAM (milled) technologies are as accurate as, or better than, conventionally produced dentures and have better material properties [45][46][47]. Moreover, high levels of patient satisfaction with digitally produced dentures have been reported [48][49]. To conclude, stomatognathic system harmony and overall health can efficiently be re-established with complete dentures, [23] and it is expected that digital technologies will provide even more efficient therapy in the future.

References

  1. Gupta, A.; Felton, D.A.; Jemt, T.; Koka, S. Rehabilitation of Edentulism and Mortality: A Systematic Review. J. Prosthodont. 2019, 28, 526–535.
  2. Broers, D.L.M.; Dubois, L.; de Lange, J.; Su, N.; de Jongh, A. Reasons for Tooth Removal in Adults: A Systematic Review. Int. Dent. J. 2022, 72, 52–57.
  3. Emami, E.; de Souza, R.F.; Kabawat, M.; Feine, J.S. The impact of edentulism on oral and general health. Int. J. Dent. 2013, 2013, 498305.
  4. Helal, M.A.; Al-Gazzar, A.E.; Abas, M.; Akhtar, S.; Gad, M.M.; Al-Thobity, A.M. Comparative Effect of Different Surface Treatments on the Shear Bond Strength of Two Types of Artificial Teeth Bonded to Two Types of Denture Base Resins. J. Prosthodont. 2022, 31, 427–433.
  5. Lee, J.S.; Weyant, R.J.; Corby, P.; Kritchevsky, S.B.; Harris, T.B.; Rooks, R.; Rubin, S.M.; Newman, A.B. Edentulism and nutritional status in a biracial sample of well-functioning, community-dwelling elderly: the health, aging, and body composition study. Am. J. Clin. Nutr. 2004, 79, 295–302.
  6. Roberto, L.L.; Crespo, T.S.; Monteiro-Junior, R.S.; Martins, A.M.E.B.L.; De Paula, A.M.B.; Ferreira, E.F.; Haikal, D.S. Sociodemographic determinants of edentulism in the elderly population: A systematic review and meta-analysis. Gerodontology 2019, 36, 325–337.
  7. Polzer, I.; Schimmel, M.; Müller, F.; Biffar, R. Edentulism as part of the general health problems of elderly adults. Int. Dent. J. 2010, 60, 143–155.
  8. Müller, F.; Naharro, M.; Carlsson, G.E. What are the prevalence and incidence of tooth loss in the adult and elderly population in Europe? Clin. Oral. Implants Res. 2007, 18 (Suppl. 3), 2–14.
  9. Al-Rafee, M.A. The epidemiology of edentulism and the associated factors: A literature Review. J. Family Med. Prim. Care 2020, 9, 1841–1843.
  10. Douglass, C.W.; Shih, A.; Ostry, L. Will there be a need for complete dentures in the United States in 2020? J. Prosthet. Dent. 2002, 87, 5–8.
  11. Borg-Bartolo, R.; Roccuzzo, A.; Molinero-Mourelle, P.; Schimmel, M.; Gambetta-Tessini, K.; Chaurasia, A.; Koca-Ünsal, R.B.; Tennert, C.; Giacaman, R.; Campus, G. Global prevalence of edentulism and dental caries in middle-aged and elderly persons: A systematic review and meta-analysis. J. Dent. 2022, 127, 104335.
  12. Paulino, M.R.; Alves, L.R.; Gurgel, B.C.; Calderon, P.S. Simplified versus traditional techniques for complete denture fabrication: A systematic review. J. Prosthet Dent. 2015, 113, 12–16.
  13. Al-Dwairi, Z.N.; Tahboub, K.Y.; Baba, N.Z.; Goodacre, C.J.; Özcan, M. A Comparison of the Surface Properties of CAD/CAM and Conventional Polymethylmethacrylate (PMMA). J. Prosthodont. 2019, 28, 452–457.
  14. Prpić, V.; Schauperl, Z.; Ćatić, A.; Dulčić, N.; Čimić, S. Comparison of Mechanical Properties of 3D-Printed, CAD/CAM, and Conventional Denture Base Materials. J. Prosthodont. 2020, 29, 524–528.
  15. Kawai, Y.; Murakami, H.; Shariati, B.; Klemetti, E.; Blomfield, J.V.; Billette, L.; Lund, J.P.; Feine, J.S. Do traditional techniques produce better conventional complete dentures than simplified techniques? J. Dent. 2005, 33, 659–668.
  16. Kawai, Y.; Murakami, H.; Takanashi, Y.; Lund, J.P.; Feine, J.S. Efficient resource use in simplified complete denture fabrication. J. Prosthodont. 2010, 19, 512–516.
  17. Regis, R.R.; Cunha, T.R.; Della Vecchia, M.P.; Ribeiro, A.B.; Silva-Lovato, C.H.; de Souza, R.F. A randomised trial of a simplified method for complete denture fabrication: Patient perception and quality. J. Oral Rehabil. 2013, 40, 535–545.
  18. Batisse, C.; Nicolas, E. Comparison of CAD/CAM and Conventional Denture Base Resins: A Systematic Review. Appl. Sci. 2021, 11, 5990.
  19. Gharechahi, J.; Asadzadeh, N.; Shahabian, F.; Gharechahi, M. Dimensional changes of acrylic resin denture bases: Conventional versus injection-molding technique. J. Dent. 2014, 11, 398–405.
  20. Zafar, M.S. Prosthodontic Applications of Polymethyl Methacrylate (PMMA): An Update. Polymers 2020, 12, 2299.
  21. Lee, H.J.; Kim, C.W.; Kim, Y.S. The Level of Residual Monomer in Injection Molded Denture Base Materials. J. Korean Acad. Prosthodont. 2003, 41, 360–368.
  22. Matos, A.O.; Costa, J.O.; Beline, T.; Ogawa, E.S.; Assunção, W.G.; Mesquita, M.F.; Consani, R.X.; Barão, V.A. Effect of Disinfection on the Bond Strength between Denture Teeth and Microwave-Cured Acrylic Resin Denture Base. J. Prosthodont. 2018, 27, 169–176.
  23. Alves, A.C.; Cavalcanti, R.V.; Calderon, P.S.; Pernambuco, L.; Alchieri, J.C. Quality of life related to complete denture. Acta Odontol. Latinoam. 2018, 31, 91–96.
  24. Prpić, V.; Schauperl, Z.; Glavina, D.; Ćatić, A.; Čimić, S. Comparison of shear bond strengths of different types of denture teeth to different denture base resins. J. Adv. Prosthodont. 2020, 12, 376–382.
  25. AlZaher, Z.A.; Almaskin, D.F.; Qaw, M.S.; Abu Showmi, T.H.; Abualsaud, R.; Akhtar, S.; Gad, M.M. Chemo-Mechanical Approach to Improve Repair Bond Strength of Denture Teeth. Int. J. Dent. 2020, 2020, 8870361.
  26. Han, S.Y.; Moon, Y.H.; Lee, J. Shear bond strength between CAD/CAM denture base resin and denture artificial teeth when bonded with resin cement. J. Adv. Prosthodont. 2020, 12, 251–258.
  27. Andrade de Freitas, S.L.; Brandt, W.C.; Miranda, M.E.; Vitti, R.P. Effect of thermocycling, teeth, and polymerization methods on bond strength teeth-denture base. Int. J. Dent. 2018, 2018, 2374327.
  28. Koodaryan, R.; Hafezeqoran, A. Effect of surface treatment methods on the shear bond strength of auto-polymerized resin to thermoplastic denture base polymer. J. Adv. Prosthodont. 2016, 8, 504–510.
  29. Gharebagh, T.G.; Hamedirad, F.; Miruzadeh, K. Comparison of bond strength of acrylic, composite, and nanocomposite artificial teeth to heat-cure acrylic denture base resin. Front. Dent. 2019, 16, 166–172.
  30. Elkassaby, A.A.; Kandil, M.M.; Alian, G.A. Microtensile vs. Flexural Bond Strength for Bond Strength Assessment. J. Res. Med. Dent. Sci. 2022, 10, 53–58.
  31. Sirisha, K.; Rambabu, T.; Shankar, Y.R.; Ravikumar, P. Validity of bond strength tests: A critical review: Part I. J. Conserv. Dent. 2014, 17, 305–311.
  32. Van Meerbeek, B.; Peumans, M.; Poitevin, A.; Mine, A.; Van Ende, A.; Neves, A.; De Munck, J. Relationship between bond-strength tests and clinical outcomes. Dent. Mater. 2010, 26, e100–e121.
  33. Klaiber, D.; Spintzyk, S.; Geis-Gerstorfer, J.; Klink, A.; Unkovskiy, A.; Huettig, F. Bonding Behavior of Conventional PMMA towards Industrial CAD/CAM PMMA and Artificial Resin Teeth for Complete Denture Manufacturing in a Digital Workflow. Materials 2021, 14, 3822.
  34. Patil, S.B.; Naveen, B.H.; Patil, N.P. Bonding acrylic teeth to acrylic resin denture bases: A review. Gerodontology 2006, 23, 131–139.
  35. Yanikoglu, D.N.; Duymus, D.Z.; Bayindir, D.F. Comparative bond strengths of autopolymerising denture resin and light cured composite resin to denture teeth. Int. Dent. J. 2002, 52, 20–24.
  36. Yoshida, Y.; Yoshihara, K.; Nagaoka, N.; Hayakawa, S.; Torii, Y.; Ogawa, T.; Osaka, A.; Van Meerbeek, B. Self-assembled nano-layering at the adhesive interface. J. Dent. Res. 2012, 91, 376–381.
  37. Akin, H.; Kirmali, O.; Tugut, F.; Coskun, M.E. Effects of different surface treatments on the bond strength of acrylic denture teeth to polymethylmethacrylate denture base material. Photomed. Laser Surg. 2014, 32, 512–516.
  38. Akin, H.; Tugut, F.; Guney, U.; Akar, T. Shear bond strength of denture teeth to two chemically different denture base resins after various surface treatments. J. Prosthodont. 2014, 23, 152–156.
  39. Rosca, B.; Ramalho, S.; Sampaio-Fernandes, J.C.; Portugal, J. Reparability of two different CAD/CAM polymer materials using a light-cured composite and universal adhesives. Rev. Port. Estomatol. Med. Dentária Cir. Maxilofac. 2016, 57, 189–196.
  40. Barragan, G.; Chasqueira, F.; Arantes-Oliveira, S.; Portugal, J. Ceramic repair: Influence of chemical and mechanical surface conditioning on adhesion to zirconia. Oral Health Dent. Manag. 2014, 13, 155–158.
  41. Seabra, B.; Arantes-Oliveira, S.; Portugal, J. Influence of multimode universal adhesives and zirconia primer application techniques on zirconia repair. J. Prosthet. Dent. 2014, 112, 182–187.
  42. Mine, A.; Kabetani, T.; Kawaguchi-Uemura, A.; Higashi, M.; Tajiri, Y.; Hagino, R.; Imai, D.; Yumitate, M.; Ban, S.; Matsumoto, M.; et al. Effectiveness of current adhesive systems when bonding to CAD/CAM indirect resin materials: A review of 32 publications. Jpn. Dent. Sci. Rev. 2019, 55, 41–50.
  43. Consani, R.L.; Naoe, H.T.; Mesquita, M.F.; Sinhoreti, M.A.; Mendes, W.B. Effect of ridge-lap surface treatments on the bond of resin teeth to denture base. J. Adhes. Dent. 2011, 13, 287–293.
  44. Srinivasan, M.; Schimmel, M.; Naharro, M.; O’Neill, C.; McKenna, G.; Müller, F. CAD/CAM milled removable complete dentures: time and cost estimation study. J. Dent. 2019, 80, 75–79.
  45. Goodacre, B.J.; Goodacre, C.J.; Baba, N.Z.; Kattadiyil, M.T. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J. Prosthet. Dent. 2016, 116, 249–256.
  46. Srinivasan, M.; Cantin, Y.; Mehl, A.; Gjengedal, H.; Müller, F.; Schimmel, M. CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness. Clin. Oral. Investig. 2017, 21, 2007–2019.
  47. Srinivasan, M.; Gjengedal, H.; Cattani-Lorente, M.; Moussa, M.; Durual, S.; Schimmel, M.; Müller, F. CAD/CAM milled complete removable dental prostheses: An in vitro evaluation of biocompatibility, mechanical properties, and surface roughness. Dent. Mater. J. 2018, 37, 526–533.
  48. Kattadiyil, M.T.; Jekki, R.; Goodacre, C.J.; Baba, N.Z. Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J. Prosthet. Dent. 2015, 114, 818–825.
  49. Bidra, A.S.; Farrell, K.; Burnham, D.; Dhingra, A.; Taylor, T.D.; Kuo, C.L. Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes. J. Prosthet. Dent. 2016, 115, 578–586.e1.
More
Information
Contributors MDPI registered users' name will be linked to their SciProfiles pages. To register with us, please refer to https://encyclopedia.pub/register : , , , ,
View Times: 278
Revisions: 2 times (View History)
Update Date: 23 Mar 2023
1000/1000