Submitted Successfully!
To reward your contribution, here is a gift for you: A free trial for our video production service.
Thank you for your contribution! You can also upload a video entry or images related to this topic.
Version Summary Created by Modification Content Size Created at Operation
1 + 1350 word(s) 1350 2022-02-11 11:27:00 |
2 Format correct Meta information modification 1350 2022-02-22 02:42:57 |

Video Upload Options

We provide professional Video Production Services to translate complex research into visually appealing presentations. Would you like to try it?

Confirm

Are you sure to Delete?
Cite
If you have any further questions, please contact Encyclopedia Editorial Office.
Abdelshafy, M. Temporary Right-Ventricular Assist Devices. Encyclopedia. Available online: https://encyclopedia.pub/entry/19693 (accessed on 18 November 2024).
Abdelshafy M. Temporary Right-Ventricular Assist Devices. Encyclopedia. Available at: https://encyclopedia.pub/entry/19693. Accessed November 18, 2024.
Abdelshafy, Mahmoud. "Temporary Right-Ventricular Assist Devices" Encyclopedia, https://encyclopedia.pub/entry/19693 (accessed November 18, 2024).
Abdelshafy, M. (2022, February 21). Temporary Right-Ventricular Assist Devices. In Encyclopedia. https://encyclopedia.pub/entry/19693
Abdelshafy, Mahmoud. "Temporary Right-Ventricular Assist Devices." Encyclopedia. Web. 21 February, 2022.
Temporary Right-Ventricular Assist Devices
Edit

Acute right-sided heart failure (RHF) is a complex clinical syndrome, with a wide range of clinical presentations, associated with increased mortality and morbidity, but about which there is a scarcity of evidence-based literature. A temporary right-ventricular assist device (t-RVAD) is a potential treatment option for selected patients with severe right-ventricular dysfunction as a bridge-to-recovery or as a permanent solution.

right-sided heart failure temporary right ventricular assist device safety efficacy

1. Introduction

Increasing use of advanced heart failure (HF) treatments including temporary and durable mechanical circularity support (MCS) are mostly directed to left-sided HF. However, concomitant or primary right-sided heart failure (RHF) are not uncommon and increases significantly morbidity and mortality [1]. This is especially vitally important in the era of long-term, durable left-ventricular assist devices (LVAD) solutions. RHF prevalence and associated mortality vary according to the underlying cause. Common clinical phenotypes are acute-on-chronic right-ventricular dysfunction with or without left-ventricular cardiomyopathy, myocardial infarction or ischemia, post-cardiotomy (PCCS), post LVAD implantation, post myocarditis, post-heart transplantation (HTX), and pulmonary thromboembolic events [1][2][3]. Management of RHF is usually medical, but in patients with imminent or full-blown cardiogenic shock, mechanical circulatory support including a right-ventricular assist device (RVAD) is indispensable. RHF usually requires temporary support in contrast to left-ventricular failure as its main pathophysiologic mechanisms, adaptive remodeling and impaired contractility, could be reversible along with lacking of established long-term, durable RVAD solutions [4]. RVAD could be surgically or percutaneously implanted and according to the duration of support could be short-term (temporary) or (rarely) long-term [1]. Despite several clinical RVAD devices, the existing literature is limited with rarely small prospective randomized trials, heterogenous, and conflicting studies, and single center cohorts.

2. Efficacy and Safety of Temporary Right-Ventricular Assist Devices

2.1. Efficacy of t-RVAD

Survival rate following t-RVAD implantation varied across different studies. It is likely related to the primary cause of RHF, the severity of end-organ dysfunction, and much less dependent on adverse events and complications related to t-RVAD. In addition, the timing of t-RVAD implantation probably plays a major role in the survival post t-RVAD. Planned t-RVAD implantation in patients at high risk of RHF likely remains the optimal strategy to improve survival. Similarly, even when t-RVAD implantation is unplanned, early t-RVAD implantation in patients with acute severe RHF are likely to improve the chance for survival than delayed implantation. Percutaneous novel developed t-RVAD represent a good option in those patients in the perioperative period [5].
Herein the largest data on t-RVAD was derived from the EUROMACS and the INTERMACS registries. Vierecke et al. [6] reported a 30-day survival of 73% in 342 patients with LVAD and t-RVAD in the EUROMACS registry. Kiernan et al. [7] reported a 30-day survival of 73.5% in 386 patients with LVAD and t-RVAD in the INTERMACS registry. A smaller study reported extreme rates of survival including Jaidka et al. [8] who reported 100% 30-day survival in 10 patients at high risk for RHF (severe baseline right ventricular dysfunction or systemic pulmonary artery pressures) underwent valve surgery and prophylactic CentriMag insertion. Likewise, the lowest 30-day survival of 45.5% was reported by Schaefer et al. [9] in 11 LVAD patients treated with t-RVAD via sternotomy in the comparative arm of the study while the 30-day survival was 80% in the main group of 10 LVAD patients treated with minimally invasive t-RVAD.
Data on the comparison of percutaneous and surgical t-RVAD is scarce. Coromilas et al. [5] reported 84.2% 30-day in 19 LVAD patients with t-RVAD percutaneously inserted mixed group of ProtekDuo (n = 15) and Impella RP (n = 4) versus 66.7% 30-day survival in 21 LVAD patients with CentriMag surgically inserted.
Likewise, data on the optimal timing of t-RVAD insertion is scarce. Khorsandi et al. [10] reported higher 30-Day survival (93.1% vs. 71.4%) in patients who received t-RVAD as concurrent (with LVAD surgery) vs. delayed (staged after LVAD) t-RVAD insertion. Moreover, Bhama et al. [11] reported 90-day survival was better (79% vs. 46%) for patients who received immediate (within 24 h of being indicated to RVAD) in comparison to delayed (after 24 h of being indicated to RVAD) t-RVAD support. Takeda et al. [12] reported numerically higher but statistically insignificant successful t-RVAD weaning (54% vs. 38% p = 0.3) for concurrent vs. delayed t-RVAD insertion. The timing of a temporary RVAD insertion is probably of utmost importance. The RVAD should be inserted as early as possible before the development of secondary organ/multi-organ failure. The best strategy depends on a good prediction of RHF, which is not established yet. One step further, the t-RVAD implantation should be probably planned prophylactic in intermediate to high-risk patients, including the selection of the best appropriate device and the best technique. In fact, the RVAD device and implantation technique selection, percutaneous versus surgical depend on the situation and the availability of the devices with consideration of the advantages offered by the percutaneous RVAD as they are less invasive, easy insertion and easy removal particularly if the RHF occurs in the ICU or perioperatively [13].
Another important aspect that might affect the t-RVAD outcome is RHF patient’s phenotypes. Overall, post-LVAD RHF patients have higher 30-day survival than other phenotypes [14][11][15][16] and higher survival to weaning in one study [17]. However, this subgroup analysis is not adequately powered to detect meaningful difference. In contrast, one study [14] reported a higher (80% vs. 67%) 30-day survival in patients with non-ischemic cardiomyopathy. Likewise, one study [18] reported a higher (75% vs. 47%) one-year survival in the post-cardiotomy patients (n = 4) than patients requiring t-RVAD support following LVAD implantation (n = 17). Although some studies [6][19][11][20][9][21][22][18][23][12][24][25] included details about the underlying disease and/or etiology of heart failure in patients undergoing LVAD, no direct comparison related to the etiology of HF was (i.e., could be) performed, mainly due to wide variation of the survival rates and other outcome measures among patients with different RHF etiologies such as post-cardiotomy or myocarditis. This reflects the fact that the primary cause of RHF and/or indication for t-RVAD were important determinants of outcome following t-RVAD implantation. Although the subgroup analysis was reported in some papers, these studies are obviously not adequately powered to detect a meaningful difference between the different RHF phenotypes/indications for t-RVAD. Furthermore, due to the significant heterogeneity, and the use of different endpoints among included studies, subgroup analyses based on data pooling was not considered. Specific for the underlying disease, almost no outcome was mentioned based on it in any paper.
In brief, the most favorable outcome was found in post-LAVD patients with early planned insertion of pRVAD versus other patients’ phenotypes or delayed insertion or insertion of sRVAD. However, this analysis also is not adequately powered to detect a meaningful difference between the different subgroups.

2.2. Duration of t-RVAD Support

Impella RP is approved for use as t-RVAD for up to 14 days only [26] also the ProtekDuo Cannulas have not been qualified through in vitro, in vivo, or clinical studies for long-term use (i.e., longer than 30 days) as mentioned by the manufacture [27]. The CentriMag is approved for use as t-RVAD up to 30 days [28]. In some studies [29][6][30], the duration of t-RVAD support exceeded the previous mentioned duration. Vierecke et al. [6] in the EUROMACS registry reported that six months after LVAD + t-RVAD implantation, more than 40% of patients who received t-RVAD remain dependent on the t-RVAD support. However, the authors did not provide details on management of RVADs during that time nor the outcome after that. Development of RHF predictive models to choose between temporary or long-term RVAD and global scientific consensus for the definition of RHF and management algorithms will contribute to solve this issue.

2.3. Safety of t-RVAD

Definitions of the reported complications following t-RVAD implantation were not clear and standardized between the studies. Acute kidney injury, bleeding, neurological events and device thrombosis were the main reported complications. Furthermore, as these complications related to percutaneously implanted t-RVAD two studies [31][15] reported the incidence of tricuspid and pulmonary valves affection and two studies [31][32] reported the incidence of superior vena cava syndrome.

3. Conclusions

Temporary RVAD is a lifesaving option for patients with severe RHF, but the evidence stems from small non-randomized heterogeneous studies utilizing a variety of devices. Both aetiology of RHF and time of intervention might play a major role in determining the temporary RVAD outcome. Standardized endpoints definitions, design and methodology for temporary RVAD trials is needed. Furthermore, efforts should continue to improve the technology as well as improve the timely provision of a temporary RVAD.

References

  1. Konstam, M.A.; Kiernan, M.S.; Bernstein, D.; Bozkurt, B.; Jacob, M.; Kapur, N.K.; Kociol, R.D.; Lewis, E.F.; Mehra, M.R.; Pagani, F.D.; et al. Evaluation and Management of Right-Sided Heart Failure: A Scientific Statement From the American Heart Association. Circulation 2018, 137, e578–e622.
  2. Soliman, O.; Muslem, R.; Caliskan, K. Right heart failure syndrome. Aging 2018, 11, 7–8.
  3. Kapur, N.K.; Esposito, M.L.; Bader, Y.; Morine, K.J.; Kiernan, M.S.; Pham, D.T.; Burkhoff, D. Mechanical Circulatory Support Devices for Acute Right Ventricular Failure. Circulation 2017, 136, 314–326.
  4. Dandel, M.; Hetzer, R. Temporary assist device support for the right ventricle: Pre-implant and post-implant challenges. Heart Fail. Rev. 2018, 23, 157–171.
  5. Coromilas, E.J.; Takeda, K.; Ando, M.; Cevasco, M.; Green, P.; Karmpaliotis, D.; Kirtane, A.; Topkara, V.K.; Yuzefpolskaya, M.; Takayama, H.; et al. Comparison of Percutaneous and Surgical Right Ventricular Assist Device Support After Durable Left Ventricular Assist Device Insertion. J. Card. Fail. 2019, 25, 105–113.
  6. Vierecke, J.; Gahl, B.; De By, T.M.M.H.; Antretter, H.; Beyersdorf, F.; Caliskan, K.; Krachak, V.; Loforte, A.; Potapov, E.; Schoenrath, F.; et al. Results of primary biventricular support: An analysis of data from the EUROMACS registry. Eur. J. Cardio-Thorac. Surg. 2019, 56, 1037–1045.
  7. Kiernan, M.S.; Grandin, E.W.; Brinkley, M.; Kapur, N.K.; Pham, D.T.; Ruthazer, R.; Eduardo Rame, J.; Atluri, P.; Birati, E.Y.; Oliveira, G.H.; et al. Early Right Ventricular Assist Device Use in Patients Undergoing Continuous-Flow Left Ventricular Assist Device Implantation: Incidence and Risk Factors from the Interagency Registry for Mechanically Assisted Circulatory Support. Circ. Heart Fail. 2017, 10, e003863.
  8. Jaidka, A.; De, S.; Nagpal, A.D.; Chu, M.W.A. Prophylactic Right Ventricular Assist Device for High-Risk Patients Undergoing Valve Corrective Surgery. CJC Open 2019, 1, 19–27.
  9. Schaefer, A.; Reichart, D.; Bernhardt, A.M.; Kubik, M.; Barten, M.J.; Wagner, F.M.; Reichenspurner, H.; Philipp, S.A.; Deuse, T. Outcomes of Minimally Invasive Temporary Right Ventricular Assist Device Support for Acute Right Ventricular Failure during Minimally Invasive Left Ventricular Assist Device Implantation. ASAIO J. 2017, 63, 546–550.
  10. Khorsandi, M.; Schroder, J.; Daneshmand, M.; Bishawi, M.; Bouamra, O.; Winterton, P.; Choi, A.Y.; Patel, C.; Rogers, J.; Del Rio, J.M.; et al. Outcomes After Extracorporeal Right Ventricular Assist Device Combined With Durable Left Ventricular Assist Device Support. Ann. Thorac. Surg. 2019, 107, 1768–1774.
  11. Bhama, J.K.; Bansal, U.; Winger, D.G.; Teuteberg, J.J.; Bermudez, C.; Kormos, R.L.; Bansal, A. Clinical experience with temporary right ventricular mechanical circulatory support. J. Thorac. Cardiovasc. Surg. 2018, 156, 1885–1891.
  12. Takeda, K.; Naka, Y.; Yang, J.A.; Uriel, N.; Colombo, P.C.; Jorde, U.P.; Takayama, H. Outcome of unplanned right ventricular assist device support for severe right heart failure after implantable left ventricular assist device insertion. J. Heart Lung Transplant. 2014, 33, 141–148.
  13. Lo Coco, V.; De Piero, M.E.; Massimi, G.; Chiarini, G.; Raffa, G.M.; Kowalewski, M.; Maessen, J.; Lorusso, R. Right ventricular failure after left ventricular assist device implantation: A review of the literature. J. Thorac. Dis. 2021, 13, 1256–1269.
  14. Shekiladze, N.; Condado, J.F.; Sandesara, P.B.; Kim, J.H.; Devireddy, C.; McDaniel, M.; Babaliaros, V.; Samady, H.; Kumar, G.; Jaber, W.A. A single healthcare experience with Impella RP. Catheter. Cardiovasc. Interv. 2020, 97, E161–E167.
  15. Anderson, M.; Morris, D.L.; Tang, D.; Batsides, G.; Kirtane, A.; Hanson, I.; Meraj, P.; Kapur, N.K.; O’Neill, W. Outcomes of patients with right ventricular failure requiring short-term hemodynamic support with the Impella RP device. J. Heart Lung Transplant. 2018, 37, 1448–1458.
  16. Cheung, A.W.; White, C.W.; Davis, M.K.; Freed, D.H. Short-term mechanical circulatory support for recovery from acute right ventricular failure: Clinical outcomes. J. Heart Lung Transplant. 2014, 33, 794–799.
  17. Loforte, A.; Montalto, A.; Ranocchi, F.; Della Monica, P.L.; Casali, G.; Lappa, A.; Contento, C.; Musumeci, F. Levitronix CentriMag third-generation magnetically levitated continuous flow pump as bridge to solution. ASAIO J. 2011, 57, 247–253.
  18. Saeed, D.; Maxhera, B.; Kamiya, H.; Lichtenberg, A.; Albert, A. Alternative right ventricular assist device implantation technique for patients with perioperative right ventricular failure. J. Thorac. Cardiovasc. Surg. 2015, 149, 927–932.
  19. Schmack, B.; Farag, M.; Kremer, J.; Grossekettler, L.; Brcic, A.; Raake, P.W.; Kreusser, M.M.; Goldwasser, R.; Popov, A.F.; Mansur, A.; et al. Results of concomitant groin-free percutaneous temporary RVAD support using a centrifugal pump with a double-lumen jugular venous cannula in LVAD patients. J. Thorac. Dis. 2019, 11, S913–S920.
  20. Yoshioka, D.; Takayama, H.; Garan, R.A.; Topkara, V.K.; Han, J.; Kurlansky, P.; Yuzefpolskaya, M.; Colombo, P.C.; Naka, Y.; Takeda, K. Contemporary outcome of unplanned right ventricular assist device for severe right heart failure after continuous-flow left ventricular assist device insertion. Interact. Cardiovasc. Thorac. Surg. 2017, 24, 828–834.
  21. Leidenfrost, J.; Prasad, S.; Itoh, A.; Lawrance, C.P.; Bell, J.M.; Silvestry, S.C. Right ventricular assist device with membrane oxygenator support for right ventricular failure following implantable left ventricular assist device placement. Eur. J. Cardio-Thorac. Surg. 2016, 49, 73–77.
  22. Deschka, H.; Holthaus, A.J.; Sindermann, J.R.; Welp, H.; Schlarb, D.; Monsefi, N.; Martens, S.; Scherer, M. Can Perioperative Right Ventricular Support Prevent Postoperative Right Heart Failure in Patients with Biventricular Dysfunction Undergoing Left Ventricular Assist Device Implantation? J. Cardiothorac. Vasc. Anesth. 2016, 30, 619–626.
  23. Patil, N.P.; Mohite, P.N.; Sabashnikov, A.; Dhar, D.; Weymann, A.; Zeriouh, M.; Hards, R.; Hedger, M.; De Robertis, F.; Bahrami, T.; et al. Preoperative predictors and outcomes of right ventricular assist device implantation after continuous-flow left ventricular assist device implantation. J. Thorac. Cardiovasc. Surg. 2015, 150, 1651–1658.
  24. Loforte, A.; Stepanenko, A.; Potapov, E.V.; Musumeci, F.; Dranishnikov, N.; Schweiger, M.; Montalto, A.; Pasic, M.; Weng, Y.; Dandel, M.; et al. Temporary right ventricular mechanical support in high-risk left ventricular assist device recipients versus permanent biventricular or total artificial heart support. Artif. Organs 2013, 37, 523–530.
  25. Khani-Hanjani, A.; Loor, G.; Chamogeorgakis, T.; Shafii, A.; Mountis, M.; Hanna, M.; Soltesz, E.; Gonzalez-Stawinski, G.V. Case series using the rotaflow system as a temporary right ventricular assist device after heartmate II implantation. ASAIO J. 2013, 59, 456–460.
  26. Impella® RP with the Automated Impella® Controller Circulatory Support System. Instructions for use & Clinical Reference Manual. Available online: https://www.accessdata.fda.gov/cdrh_docs/pdf14/H140001d.pdf (accessed on 28 October 2021).
  27. TandemLife. Indication for Use Safety Inforamtion. Available online: http://www.tandemlife.com/indications-use-safety-information/ (accessed on 27 October 2021).
  28. CentriMag™ Blood Pump Instructions For Use (IFU). Available online: http://www.accessdata.fda.gov/cdrh_docs/pdf17/P170038C.pdf (accessed on 28 October 2021).
  29. Oliveros, E.; Collado, F.M.; Poulin, M.F.; Seder, C.W.; March, R.; Kavinsky, C.J. Percutaneous Right Ventricular Assist Device Using the TandemHeart ProtekDuo: Real-World Experience. J. Invasive Cardiol. 2021, 33, E407–E411.
  30. Aissaoui, N.; Morshuis, M.; Paluszkiewicz, L.; Lauenroth, V.; Börgermann, J.; Gummert, J. Comparison of biventricular and left ventricular assist devices for the management of severe right ventricular dysfunction in patients with end-stage heart failure. ASAIO J. 2014, 60, 400–406.
  31. Salna, M.; Garan, A.R.; Kirtane, A.J.; Karmpaliotis, D.; Green, P.; Takayama, H.; Sanchez, J.; Kurlansky, P.; Yuzefpolskaya, M.; Colombo, P.C.; et al. Novel percutaneous dual-lumen cannula-based right ventricular assist device provides effective support for refractory right ventricular failure after left ventricular assist device implantation. Interact. Cardiovasc. Thorac. Surg. 2020, 30, 499–506.
  32. Badu, B.; Cain, M.T.; Durham, L.A.; Joyce, L.D.; Sundararajan, S.; Gaglianello, N.; Ishizawar, D.; Saltzberg, M.; Mohammed, A.; Joyce, D.L. A Dual-Lumen Percutaneous Cannula for Managing Refractory Right Ventricular Failure. ASAIO J. 2020, 66, 915–921.
More
Information
Contributor MDPI registered users' name will be linked to their SciProfiles pages. To register with us, please refer to https://encyclopedia.pub/register :
View Times: 438
Revisions: 2 times (View History)
Update Date: 22 Feb 2022
1000/1000
ScholarVision Creations