Tissue Biomechanical Parameters Identification for Robot-Assisted Palpation
Academic Video Service
All videos are free for registered users. Please login to proceed.
  • View Times: 37
  • |
  • Update Date: 28 Nov 2022
  • robotics
  • palpation
  • sensorless
  • biomedical
  • force sensors
Video Introduction

This video is adapted from 10.3390/s22228670

The implementation of robotic systems for minimum invasive surgery and medical procedures is an active topic of research in recent years. One of the most common procedures is the palpation of soft tissues to identify their mechanical characteristics. In particular, it is very useful to identify the tissue stiffness or equivalently its elasticity coefficient. This identification relies on the existence of a force sensor or a tactile sensor mounted at the tip of the robot, as well as on measuring the robot velocity. For some applications it would be desirable to identify the biomechanical characteristics of soft tissues without the needing of a force/tactile nor velocity sensors. An estimation of such quantities can be obtained by a model-based state observer for which the inputs are only the robot joint positions and its commanded joint torques. The estimated velocities and forces can then be employed for closed-loop force control, force reflection, and mechanical parameters estimation. A closed-loop force control is proposed based on the estimated contact forces to avoid any tissue damage. Then, the information from the estimated forces and velocities is used in a least squares estimator of the mechanical parameters. Moreover, the estimated biomechanical parameters are employed in a Bayesian classifier to provide further help for the physician to make a diagnose. Researchers have found that a combination of the parameters of both a linear and a nonlinear viscoelastic models provide better classification results: 0% misclassifications against 50% when using a linear model, and 3.12% when using only a nonlinear model, for the case in which the samples have very similar mechanical properties.

Full Transcript
1000/1000
Hot Most Recent

Confirm

Are you sure to Delete?
Yes No
Cite
If you have any further questions, please contact Encyclopedia Editorial Office.
Gutiérrez-Giles, A.; Padilla-Castañeda, M.�.; Alvarez–Icaza, L.; Gutiérrez, E. Tissue Biomechanical Parameters Identification for Robot-Assisted Palpation. Encyclopedia. Available online: https://encyclopedia.pub/video/video_detail/505 (accessed on 05 December 2025).
Gutiérrez-Giles A, Padilla-Castañeda M�, Alvarez–Icaza L, Gutiérrez E. Tissue Biomechanical Parameters Identification for Robot-Assisted Palpation. Encyclopedia. Available at: https://encyclopedia.pub/video/video_detail/505. Accessed December 05, 2025.
Gutiérrez-Giles, Alejandro, Miguel Ángel Padilla-Castañeda, Luis Alvarez–Icaza, Enoch Gutiérrez. "Tissue Biomechanical Parameters Identification for Robot-Assisted Palpation" Encyclopedia, https://encyclopedia.pub/video/video_detail/505 (accessed December 05, 2025).
Gutiérrez-Giles, A., Padilla-Castañeda, M.�., Alvarez–Icaza, L., & Gutiérrez, E. (2022, November 25). Tissue Biomechanical Parameters Identification for Robot-Assisted Palpation. In Encyclopedia. https://encyclopedia.pub/video/video_detail/505
Gutiérrez-Giles, Alejandro, et al. "Tissue Biomechanical Parameters Identification for Robot-Assisted Palpation." Encyclopedia. Web. 25 November, 2022.
Academic Video Service