Contemporary Methods of Measuring Methane Emission from Ruminants: History
Please note this is an old version of this entry, which may differ significantly from the current revision.
Methane is the second most important anthropogenic greenhouse gases (GHG) in terms of global warming potential (GWP) and quantity and is responsible for 20% of the global warming caused by anthropogenic GHG emissions. The global annual CH4 emission from ruminant livestock is estimated to be between 80 and 95 million tons. CH4 production is also a loss of energy availability to the host ruminant animal, normally representing between 2% and 12% of the total gross energy intake, depending on the level of intake and diet composition. There is immense interest to develop an accurate ruminant CH4 emission of accounting to reduce the negative effects of GHGs on the environment and to evaluate mitigation strategies. Several methods have been developed to measure CH4 emissions from ruminants.
  • ruminant
  • emission
  • CH4

1. Widely Used Methods

1.1. Respiration Chambers (Direct Measurements)

Respiration chambers (RC) have been used for studying the energy metabolism of animals and methane (CH4) energy losses of ruminants for more than 100 years [1][2][3]. The principle of the RC technique relies on measuring CH4 concentrations released from enteric fermentation (nasal and rectum) in gas samples and the total volume of air removed from the RC [1][4][5][6]. The chamber method uses only a few animals for continuous monitoring, usually over a course of 24 h periods, for 3–7 days [3][7]. Changes in O2, CO2, and CH4 contents are calculated from the gas flow, and changes in gas concentrations between the air inlet and outlet are measured using gas analyzers, infrared (IR) photoacoustic monitors, or gas chromatography systems [8][9]. Respiration chambers provide an accurate reference method used for research purposes [7].
There are two types of RC: closed-circuit and open-circuit [10]. While the closed-circuit systems are these days almost never used, the open-circuit chambers are currently the most commonly used, with varying degrees of complexity [3][5]. Gas recovery is an essential routine maintenance task while performing RC experiments. Thresholds for the chamber temperature, relative humidity, CO2 concentration, and ventilation rate are <27 °C, <90%, <0.5%, and 250–260 L/min, respectively [8].
Chambers need to be routinely calibrated and demonstrate gas recovery rates of close to 100%, both before and after each experimental deployment [11][12]. However, in practice, it is estimated that the average recovery value is 98.1% [13]. Respiration chambers have low animal-to-animal variations and good refinement in CH4 measurements. They are suitable for studying the differences between treatments for mitigation strategies and are still regarded as the “gold standard” method for measuring individual animal CH4 emissions [6][8][12]. However, RC use is technically demanding, and only a few animals can be monitored at the same time [14]. The chamber method has both high investment and labor costs [7]. Animals’ behavior is supposed to be affected by the artificial environment created by the method, and it is not suitable for free-ranging animals [1]. Nevertheless, RCs are the most appropriate for providing continuous and accurate data on air composition over an extended period of time [8].

1.2. In Vitro Incubation (Indirect Measurements)

The basic principle of the in vitro technique is incubating feed under gas-tight culture bottles involving natural rumen microbes under an anaerobic environment [1][8]. The gas measuring technique has been widely used for evaluating the nutritive value of feeds and simulating ruminal fermentation of feed and feedstuffs [5][15]. In this technique, feedstuffs are incubated for a specific time frame (2, 4, 8, 24, 48, 72, 96 and/or 144 h) with a mixture of reducing solution, buffer, and rumen fluid at 39 °C [4]. In the meantime, the total gas production and CH4 are measured [1]. Blank samples with no feedstuffs are also run to correct for the amount of background gas produced.
The method requires access to fresh rumen fluid from fistulated animals, collected by esophageal tubing on intact animals or from slaughtered animals [4]. The method is ideal to screen different feedstuffs within a short time (1–4 weeks) in a controlled environment [1][4]. One way of determining the kinetic parameter of total gas production is by using the nonlinear curve fitting procedure in GenStat and SAS [8][16]. Syringes; Rusitec; closed vessel batch fermentation and fully automated systems have been used for CH4 determination [17][18][19][20]. The method allows as many replications in one batch to discern differences among treatments [1]. The result of this technique can serve as input to optimize larger and more expensive in vivo experiments [4]. However, the system can only simulate the ruminal fermentation of feed. Furthermore, under normal conditions, the system lacks to capture the thriving environment of rumen microorganisms in the tested feedstuffs [1].

1.3. The Sulfur Hexafluoride (SF6) (Direct Measurements)

The sulfur hexafluoride tracer method was first developed at Washington State University [21] and described in 1993–1994 by [22]. It is a widely used technique to measure enteric CH4 emissions [12]. The technique provides a direct measurement of the CH4 emission of individual animals [8]. The purpose of the SF6 technique is to investigate how much CH4 does the penned as well as free-ranging and grazing animals produce over a given period (24h feeding cycle) [3][4][23]. SF6 is a non-toxic, physiologically inert, and stable gas that is easy to detect, even in minute amounts [4][5][24]. In addition, SF6 gas mixes with rumen air in the same way as CH4 [1].
The principle behind this method is that from the rumen, the SF6 gas release rate is determined in order to calculate the CH4 emission measurement [6][22][25]. The SF6 gas release rate could be achieved by placing an SF6 filled permeation tube in a 39 °C water bath. Once the release rate is known and reaches stability, the permeation tube will be placed in the rumen of the study animals [1].
The sampling apparatus consists of a small brass permeation tube placed in the rumen and a lightweight “yoke”, fitted with a collection PVC canister, a halter and capillary tubing in which an air-evacuated canister draws air at a slow and steady rate from near the animal’s nostrils [1][4][5][21][23]. Eructated gas samples release both SF6 and CH4 from their nostrils, and some of this is sucked into the canister (along with air surrounding the animal) [4][23]. The ratio of CH4:SF6 in the canister is used to determine the daily CH4 emission with each gas corrected for background concentration. The concentration of SF6 and CH4 in the canister is determined by gas chromatography [5], in conjunction with the pre-determined SF6 permeation rate of the tubes [3][25][26]. Samples are advised to be taken over 24 h intervals, over a minimum period of five sequential days, with background air samples collected alongside animals at the same time [3]. The following equation is used to determine CH4 emission using the SF6 technique [6].
CH4 (g /day) = SF6 (g /day) × ([CH4]c − [CH4] b)/ ([SF6]c − [SF6] b)
where [CH4]c and [SF6]c are the concentrations of CH4 and SF6 in the canister, respectively; while [CH4] b and [SF6] b are the CH4 and SF6 concentrations in the background air, respectively [6].
In theory, the SF6 technique is recommended for grazing cattle involving large herds (n > 50), [5][27]. Furthermore, it can also be employed under more controlled conditions where the intake is measured and/or regulated [8]. The duration of collection of each sample is regulated by altering the length and/or diameter of the capillary tube [1][22].

2. Spot Sampling Methods

Collecting adequate short-term breath data for measurements of emission are the essence of spot sampling methods [7]. The methods use spot measurement of exhaled CH4 at milking or during feeding. Such methods are usually automated, non-invasive and non-intrusive, allowing a high throughput of animals [3]. Adequate data provide a repeatable estimate of emission rate and scale up from a short-term emission rate to CH4 emissions for the whole day [5].

2.1. Sniffer Method

The idea of the sniffer method was first gestated by Garnsworthy et al. [28]. This method is based on short-duration continuous breath analysis of exhaled air from the feed troughs in automatic milking systems (AMS) or concentrate feeders (CF) [7]. To collect air eructed by animals during milking, a sample inlet is inserted in the feed manager of an autonomous milking system [28]. The sniffer method sample analysis is based on continuous sampling of air in the manager using data recorders to monitor CH4 and CO2 concentrations near the animal’s muzzle [6]. This method provides an estimate of total daily emissions by individual animals on-farm [3]. It also provides hundreds of repeated measurements over prolonged periods [12]. However, studies using the sniffer method have shown, a high between-animal coefficient of variation (CV) as compared to the RC and flux method [7][29][30][31]. In addition, with this method, CH4 and CO2 concentrations are highly influenced by the distance of the animal’s head from the point of sampling, which is not an issue with total-air sampling [32].

2.2. GreenFeed

GreenFeed® (GF) is a patented, commercially available gas-flux quantification system (C-lock Inc., Rapid City, SD, USA) that combines an automatic feeding system with measures of CH4, CO2, airflow, and the detection of head position during each animal’s visit to the unit [7][8][33]. The GF method is based on the idea that many short-term CH4 emission samples from an individual animal, taken several times throughout a day, can be aggregated to estimate an animal’s average daily CH4 emission across several days/weeks/months [3]. The system measures CH4 emissions from non-confined cattle and sheep and records short-term data (3–6 min) repeatedly over 24 h by attracting animals to the unit using a “bait” of pelleted concentrate [4][8]. This method uses a similar principle for measuring gas emissions as for respiration chambers (flux method) [7]. What makes the (GF) method special is that there are sensors that measure the concentration of CH4 released from the animal’s mouth during the several minutes that the animal is feeding [4]. The head sensor also detects if the head of the cow is in the correct position before using the exhaled CH4 concentration values for further calculations of the flux.
The GF system is embedded with automatic baiting, measurements of airflow and gas concentrations, electronics, communication devices, and a gas tracer device. Animal visits result in a feed reward and measurement of CH4 emission after a specified time has elapsed between visits (determined by the investigator) [1][3][6]. Daily CH4 emissions are estimated from multiple short-duration visits to the feed station over 1–2 weeks [4]. Daily CH4 emission CH4 (L/min) is calculated using the volumetric airflow rate (Fair (i)) adjusted to STP and corrected for the capture rate.
CH4 (L/min) = Cp(i) × ([CH4]c(i) − [CH4] b(i)) × Fair(i) /106
where Cp(i) is the fractional capture rate of air at time i; [CH4]c(i) and [CH4]b(i) are the concentrations of captured gas (ppm) and background gas of CH4 (ppm), respectively, at time i; and Fair(i) is the volumetric airflow rate (L/min) measured on a dry-gas basis at time i. [6][7]. The system provides comparable estimates to those produced both by RC and SF6 techniques [8][34]. The measurements with sufficient duration (at least 3 min), and 30 observations were enough to obtain reliable CH4 emission data, regardless of how many times per day the measurements were obtained [12][35]. For measuring CH4 emissions from individual animals, GF is a more cost-effective method than both SF6 and RC, both indoors and in pastures [3][12].

2.3. Face Mask Method

The principle of face mask (FM) for spot samplings of respiratory exchange and CH4 emissions is based on animals trained to stay in sternal recumbency for 30 min measurement periods taken every 2–3 h with up to 7 measurements per day [36][37]. The method has been used to measure emissions from cattle, sheep, and goats [3]. The principle of this method is similar to RC in terms of measuring gas exchange and changes in the exhaled CH4 concentration. It includes a mass flow controller, gas sampling unit, and CH4 emission analyzer attached to each face mask, where gas measurements are corrected for differences in humidity, lag time, drift, and CH4 emission (mL/min) for each period [38]. The FM method is comparatively cheaper and simpler than SF6 or RC. Its mobility provides access to measure multiple locations to collect CH4 emissions [39]. However, the number of measurements presented had a marked impact on animal behavior, as access to food and water was restricted during measurement periods. The FM method was also considered too laborious and interest in using the method to measure enteric CH4 from ruminants has faded [38].

2.4. Portable Accumulation Chambers

A portable accumulation chamber (PAC) system is essentially an airtight box without airflow [3][6]. The PAC consist of a clear polycarbonate box that has an opening at the bottom and that is sealed by achieving close contact with flexible rubber matting [8]. The method uses a portable air sampler and analyzer unit based on transform IR detection [5]. In this technique, PAC traps all exhaled gases during 2 h of sampling, during which oxygen is depleted, and a single measurement of CH4 is taken at the end of the sampling [32][40].
One of the advantages of the PAC system is to facilitate easy access to emission measurements on grazing conditions, something not possible with immobile open-circuit chambers [8]. It allows for screening a large number of ruminants for an efficient CH4 emission measurement [8]. However, the time of measurements relative to feeding and any postprandial changes in CH4 emission is a potential source of variation in these measurements and thus, should be accounted for when the method is used [3].

3. Laser Technologies to Measure Enteric CH4 Emission

3.1. The Laser CH4 Detector (Direct Measurements)

The use of lasers for gas detection has traditionally been used in environmental monitoring, air-quality monitoring, security, and health care [41]. A laser CH4 detector (LMD) is used to monitor exhaled air CH4 concentrations in the air between the laser device and the animal’s nose or mouth [12][42]. The LMD method is based on IR-absorption spectroscopy to establish the CH4 concentration measurement [41]. It allows measurements of CH4 emissions from the same animals repeatedly in their normal environments [6]. Measurements of CH4 concentration are taken manually by a portable apparatus approximately 1–3 m from the animal [3]. The technique is similar to automated measurements of CH4 concentration in exhaled air samples during milking or feeding, except here, measurements are taken from the animals’ nostrils [28]. The advantages of LMD over the traditional enteric CH4 measurement techniques are that the LMD is a non-invasive, non-contact technique, with a fast response, and enables real-time measurements [41]. The author [41] concluded that LMD reflects a strong agreement between those recorded in the indirect open-circuit respiration calorimetric chambers [41]. However, the LMD technique is affected by factors, such as temperature, wind velocity, the proximity of other animals, humidity, and atmospheric pressure [6][12]. In a recent review by Sorg [43], it was suggested that the LMD method could be an alternative in situations where other methods are not suitable for use.

3.2. Open-Path Laser (Direct Measurements)

Open-path laser is a novel method for quantifying CH4 emissions during feeding. It is currently been used to measure enteric CH4 emissions from herds of animals [8]. The concept of this technique relies on lasers and wireless sensor networks that send beams of light from the herds of animals to an open-path tunable diode detector to analyze CH4 from grazing animals by IR-absorption spectroscopy [44][45]. The laser comprises upwind and downwind paths for the predominant wind direction of the herd. The herd acts as a surface source or, when individual animals can be fitted with GPS collars, individual animals are treated as point sources. By combining the micrometeorological data, the method possibly measures whole-farm CH4 emissions across several pastures [8]. However, wind directions, surface roughness, or periods of unfavorable atmospheric conditions (fog, rain, waves, heat, etc.) are a particular concern for the application of this technique [46].

4. Micrometeorological Methods

Micrometeorological methods are based on gas-flux measurements in the free atmosphere and the corresponding emission rates of animals [1][47]. The methods rely on concomitant measurements of wind velocity and CH4 concentration [5]. For gas analysis, Fourier Transform Infrared (FTIR) spectroscopy is integrated into the system. However, there are differences in the measurement techniques and the calculation of emission rates. Some of the techniques available for emission measurements include mass balance, vertical flux, and Lagrangian dispersion analyses [47]. An advantage of these techniques is that it is possible to study animals within their normal production setting and the measurements can be made on a potentially large number of animals [47]. In addition, the methods can incorporate the measurement of footprint over larger areas [5]. It was confirmed that micrometeorological methods could give similar values of CH4 emission compared to open-circuit respiration chambers [1][48]. It is, however, not possible to detect emissions from indoor-housed animals as well as from individual animals by using micrometeorological methods [6].

This entry is adapted from the peer-reviewed paper 10.3390/methane1020008

References

  1. Storm, I.M.L.D.; Hellwing, A.L.F.; Nielsen, N.I.; Madsen, J.O. Methods for Measuring and Estimating Methane Emission from Ruminants. Animals 2012, 2, 160–183.
  2. Armsby, H.P. The Principles of Animal Nutrition; J. Wiley & Sons: New York, NY, USA, 1903. Available online: http://hdl.loc.gov/loc.gdc/scd0001.00008948185 (accessed on 10 September 2020).
  3. Hammond, K.J.; Waghorn, G.C.; Hegarty, R.S. The GreenFeed system for measurement of enteric methane emission from cattle. Anim. Prod. Sci. 2016, 56, 181–189.
  4. Okpara, M.O. Methane Emissions in Ruminants: Perspectives on Measurement and Estimation Methods. Russ. Agric. Sci. 2018, 44, 290–294.
  5. Brouček, J. Methods of methane measurement in ruminants. Slovak J. Anim. Sci. 2014, 47, 51–60.
  6. Patra, A.K. Recent Advances in Measurement and Dietary Mitigation of Enteric Methane Emissions in Ruminants. Front. Vet. Sci. 2016, 3, 39.
  7. Huhtanen, P.; Cabezas-Garcia, E.H.; Utsumi, S.; Zimmerman, S. Comparison of methods to determine methane emissions from dairy cows in farm conditions. J. Dairy Sci. 2015, 98, 3394–3409.
  8. Goopy, J.P.; Chang, C.; Tomkins, N. A Comparison of methodologies for measuring methane emissions from ruminants. In Methods for Measuring Greenhouse Gas Balances and Evaluating Mitigation Options in Smallholder Agriculture; Rosenstock, T., Rufino, M., Butterbach-Bahl, K., Wollenberg, L., Richards, M., Eds.; Springer: Cham, Switzerland, 2016.
  9. Hellwing, A.L.F.; Lund, P.; Weisbjerg, M.R.; Brask, M.; Hvelplund, T. Technical note: Test of a low-cost and animal-friendly system for measuring methane emissions from dairy cows. J. Dairy Sci. 2012, 95, 6077–6085.
  10. Wainman, F.W.; Blaxter, K.L. Closed-Circuit Respiration Apparatus for the Cow and Steer. In Proceedings of the 1st Symposium in Energy Metabolism, Principles, Methods and General Aspects, Copenhagen, Denmark, 15–19 September 1958; pp. 80–84.
  11. Gerrits, W.; Labussière, E.; Reynolds, M.C.; Kuhla, B.; Lund, P.; Weisbjerg, M.; Dijkstra, J. Letter to the Editor: Recovery test results as a prerequisite for publication of gaseous exchange measurements. Dairy Sci. 2018, 101, 4703–4704.
  12. Hristov, A.; Kebreab, E.; Niu, M.; Oh, J.; Bannink, A.; Bayat, A.; Boland, T.; Brito, A.; Casper, D.; Crompton, L.; et al. Symposium review: Uncertainties in enteric methane inventories, measurement techniques, and prediction models. J. Dairy Sci. 2018, 101, 6655–6674.
  13. Li, D.H.; Kim, B.G.; Lee, S.R. A respiration-metabolism chamber system for measuring gas emission and nutrient digestibility in small ruminant animals. Rev. Colomb. Cienc. Pecu. 2010, 23, 444–450.
  14. McGinn, S.M.; Chen, D.; Loh, Z.; Hill, J.; Beauchemin, K.A.; Denmead, O.T. Methane emissions from feedlot cattle in Australia and Canada. Aust. J. Exp. Agric. 2008, 48, 183–185.
  15. Rymer, C.; Huntington, J.A.; Williams, B.A.; Givens, D.I. In vitro cumulative gas production techniques: History, methodological considerations and challenges. Anim. Feed Sci. Technol. 2005, 123–124, 9–30.
  16. Payne, R.W.; Murray, D.A.; Harding, S.A. An Introduction to the GenStat Command Language, 14th ed.; VSN International: Hemel Hempstead, UK, 2011.
  17. Blümmel, M.; Ørskov, E.R. Comparison of in vitro gas production and nylon bag degradability of roughages in predicting feed intake in cattle. Anim. Feed Sci. Technol. 1993, 40, 109–119.
  18. Bhatta, R.; Tajima, K.; Takusari, N.; Higuchi, K.; Enishi, O.; Kurihara, M. Comparison of sulfur hexafluoride tracer technique, rumen simulation technique and in vitro gas production techniques for methane production from ruminant feeds. Int. Congr. Ser. 2006, 1293, 58–61.
  19. Navarro-Villa, A.; O’Brien, M.; Lopez, S.; Boland, T.M.; O’Kiely, P. Modifications of a gas production technique for assessing in vitro rumen methane production from feedstuffs. Anim. Feed Sci. Technol. 2011, 166–167, 163–174.
  20. Pellikaan, W.F.; Hendriks, W.H.; Uwimana, G.; Bongers, L.J.G.M.; Becker, P.M.; Cone, J.W. A novel method to determine simultaneously methane production during in vitro gas production using fully automated equipment. Anim. Feed Sci. Technol. 2011, 168, 196–205.
  21. DeRamus, H.A.; Clement, T.C.; Giampola, D.D.; Dickison, P.C. Methane emissions of beef cattle on forages: Efficiency of grazing management systems. J. Environ. Qual. 2003, 32, 269–277.
  22. Johnson, K.; Huyler, M.; Westberg, H.; Lamb, B.; Zimmerman, P. Measurement of methane emissions from ruminant livestock using a sulfur hexafluoride tracer technique. Environ. Sci. Technol. 1994, 28, 359–362.
  23. Zimmerman, P.R. System for Measuring Metabolic Gas Emissions from Animals. U.S. Patent 5265618, 30 December 1993.
  24. Johnson, K.; Huyler, M.; Pierce, C.S.; Lamb, B.; Zimmermann, P. The use of SF6 as an inert gas tracer for use in methane measurements. J. Anim. Sci. 1992, 70, 302.
  25. Harper, L.A.; Denmead, O.T.; Freney, J.R.; Byers, F.M. Direct measurements of methane emissions from grazing and feedlot cattle. J. Anim. Sci. 1999, 77, 1392–1401.
  26. Williams, S.R.O.; Moate, P.J.; Hannah, M.C.; Ribaux, B.E.; Wales, W.J.; Eckard, R.J. Background matters with the SF6 tracer method for estimating enteric methane emissions from dairy cows: A critical evaluation of the SF6 procedure. Anim. Feed Sci. Technol. 2011, 170, 265–276.
  27. McSweeney, C. Measuring Methane in the Rumen under Different Production Systems as a Predictor of Methane Emissions. CCH.6210 Final Report. 2015. Available online: https://www.mla.com.au/ (accessed on 20 March 2019).
  28. Garnsworthy, P.C.; Craigon, J.; Hernandez-Medrano, J.H.; Saunders, N. On-farm methane measurements during milking correlate with total methane production by individual dairy cows. J. Dairy Sci. 2012, 95, 3166–3180.
  29. Yan, T.; Mayne, C.S.; Gordon, F.G.; Porter, M.G.; Agnew, R.E.; Patterson, D.C.; Ferris, C.P.; Kilpatrick, D.J. Mitigation of enteric methane emissions through improving efficiency of energy utilization and productivity in lactating dairy cows. J. Dairy Sci. 2010, 93, 2630–2638.
  30. Zimmerman, S.; Brito, A.; Huhtanen, P.; Johnson, K.; Michal, J.; Pereira, A.; Pineras, C.; Utsumi, S.; Waghorn, G.; Zimmerman, P. Measurement and evaluation of enteric CH4 emissions and variability in production systems. Adv. Anim. Biosci. 2013, 4, 518.
  31. Bell, M.J.; Saunders, N.; Wilcox, R.; Homer, E.; Goodman, J.; Craigon, J.; Garnsworthy, P. Methane emissions among individual dairy cows during milking quantified by eructation peaks or ratio with carbon dioxide. J. Dairy Sci. 2014, 97, 6536–6546.
  32. Hegarty, R.S. Applicability of short-term emission measurements for on-farm quantification of enteric methane. Animal 2013, 7, 401–408.
  33. Zimmerman, P.R.; Zimmerman, R.S. Method and System for Monitoring and Reducing Ruminant Methane Production. U.S. Patent US20090288606A, 26 November 2009.
  34. Hammond, K.; Humphries, D.; Crompton, L.; Kirton, P.; Green, C.; Reynolds, C. Methane Emissions from Growing Dairy Heifers Estimated Using an Automated Head Chamber (GreenFeed) Compared to Respiration Chambers or SF6 Techniques. Adv. Anim. Biosci. 2013, 4, 391.
  35. Arthur, P.F.; Barchia, I.M.; Weber, C.; Bird-Gardiner, T.; Donoghue, K.A.; Herd, R.M.; Hegarty, R.S. Optimizing test procedures for estimating daily methane and carbon dioxide emissions in cattle using short-term breath measures. J. Anim. Sci. 2017, 95, 645–656.
  36. Washburn, L.E.; Brody, S. Growth and development with special reference to domestic animals. Methane, hydrogen, and carbon dioxide production in the digestive tract of ruminants in relation to the respiratory exchange. Univ. Missouri. Coll. Agric. Agric. Exp. Stat. Res. Bull. 1937, 263, 614.
  37. Bhatta, R.B.; Nishi, O.; Kurihara, M. Measurement of Methane Production from ruminants. Asian-Aust. J. Anim. Sci. 2007, 20, 1305–1318.
  38. Oss, D.B.; Marcondes, M.I.; Machado, F.S.; Pereira, L.G.R.; Tomich, T.R.; Ribeiro, G.O.; Chizzotti, M.L.; Ferreira, A.L.; Campos, M.M.; Maurício, R.M.; et al. An evaluation of the face mask system based on short-term measurements compared with the sulfur hexafluoride (SF 6) tracer, and respiration chamber techniques for measuring CH4 emissions. Anim. Feed Sci. Technol. 2016, 216, 49–57.
  39. Brosh, A. Heart rate measurements as an index of energy expenditure and energy balance in ruminants: A review. J. Anim. Sci. 2007, 85, 1213–1227.
  40. Goopy, J.P.; Woodgate, R.; Donaldson, A.; Robinson, D.L.; Hegarty, R.S. Validation of a short-term methane measurement using portable static chambers to estimate daily methane production in sheep. Anim. Feed Sci. Technol. 2011, 166–167, 219–226.
  41. Chagunda, M.G.G. Opportunities and challenges in the use of the Laser Methane Detector to monitor enteric methane emissions from ruminants. Animal 2013, 7, 394–400.
  42. Ricci, P.; Chagunda, M.G.G.; Rooke, J.; Houdijk, J.G.M.; Duthie, C.-A.; Hyslop, J.; Roehe, R.; Waterhouse, A. Evaluation of the laser methane detector to estimate methane emissions from ewes and steers. J. Anim. Sci. 2014, 92, 5239–5250.
  43. Sorg, D. Measuring Livestock CH4 Emissions with the Laser Methane Detector: A Review. Methane 2022, 1, 38–57.
  44. Troy, S.; Rooke, J.A.; Duthie, C.A.; Ross, D.; Hyslop, J.J.; Roehe, R. Measurement of methane from finishing cattle fed either a forage-based or high concentrate diet from both feeder-mounted samplers and respiration chambers. Adv. Anim. Biosci. 2013, 4, 551.
  45. Rey-Sanchez, C.; Bohrer, G.; Slater, J.; Li, Y.-F.; Grau-Andrés, R.; Hao, Y.; Rich, V.I.; Davies, G.M. The ratio of methanogens to methanotrophs and water-level dynamics drive methane transfer velocity in a temperate kettle-hole peat bog. Biogeosciences 2019, 16, 3207–3231.
  46. Loh, Z.; Chen, D.; Bai, M.; Naylor, T.; Griffith, D.; Hill, J.; Denmead, T.; McGinn, S.; Edis, R. Measurement of greenhouse gas emissions from Australian feedlot beef production using open-path spectroscopy and atmospheric dispersion modelling. Aust. J. Exp. Agric. 2008, 48, 244–247.
  47. Harper, L.A.; Denmead, O.T.; Flesch, T.K. Micrometeorological techniques for measurement of enteric greenhouse gas emissions. Anim. Feed Sci. Technol. 2011, 166–167, 227–239.
  48. Tomkins, N.W.; McGinn, S.M.; Turner, D.A.; Charmley, E. Comparison of open-circuit respiration chambers with a micrometeorological method for determining methane emissions from beef cattle grazing a tropical pasture. Anim. Feed Sci. Technol. 2011, 166–167, 240–247.
More
This entry is offline, you can click here to edit this entry!
ScholarVision Creations