Air Quality Management: History
Please note this is an old version of this entry, which may differ significantly from the current revision.
Contributor: ,

Most of the Ecuador buses run on diesel, emitting high quantities  NOx and PM2.5.  Into the framework of promoting the use of low impact energy and efficiency, the Ecuadorian energy efficiency law requires by 2025 that all vehicles incorporated into the public transportation system must be electric. To assess the effects on the air quality of Cuenca, a city located al the Southern Andean region of Ecuador, we used the Eulerian Weather Research and Forecasting with Chemistry (WRF-Chem) model. The results were consistent with the pollutants' trends observed during the COVID-19 lockdown in this city.

  • WRF-Chem, Weekend-effect, COVID-19 lockdown

Note:All the information in this draft can be edited by authors. And the entry will be online only after authors edit and submit it.

1. Introduction

On-road traffic is one of the most important sources of air pollutants in cities located in Ecuador [1,2]. Emissions from this source are exacerbated for cities located in the Andean region of the country, owing to their altitude, where the content of atmospheric oxygen is lower compared to at sea level. Therefore, combustion processes emit more primary pollutants in these cities [3].

In Cuenca (Lon. −79.0°, Lat. −2.9°, 2500 m. a.s.l.), which is a city located in the Southern Andean region of the country (Figure 1), during 2014, on-road traffic, among other pollutants, emitted 5981.0 and 384.0 t y−1 of NOx (NO + NO2) and PM2.5, respectively, representing 71.2% and 42.2% of the total emissions of each pollutant [4].

NOx (NO + NO2) is mainly produced by the combination of atmospheric N2 and O2, when, under high temperatures and pressures, air is mixed with fuel in engines. Diesel engines work at pressures 1.5 times higher than those of gasoline engines of a comparable power [5], producing high quantities of NOx. Additionally, diesel vehicles emit 10 to 100 times more particulate mass than gasoline vehicles [6] and are major sources of nanoparticles [7].

Ozone (O3) is a secondary air pollutant produced from photochemical interactions between NOx and volatile organic compounds (VOC), through complex reactions under the influence of solar radiation [8]. Sources of VOC are diverse, including gasoline cars, service stations, the use of solvents, and vegetation.

NO2 can increase the airway reactivity to cold air in asthmatics and the susceptibility to bacterial and viral infections of the lung [9]. O3 is a strong oxidant and reactive pollutant, which increases the airway responsiveness, airway inflammation, respiratory infections, tissue permeability, exacerbation of asthma, and pulmonary function impairment [9,10].

PM2.5 exhibits effects after both short-term and long-term exposure. Current World Health Organization (WHO) guidelines cannot guarantee complete protection against PM2.5 effects [11], thus requiring the lowest possible concentrations to be achieved. Short-term exposition includes cardiovascular and respiratory effects. The International Agency for Research on Cancer (IARC) has classified outdoor air pollution and particulate matter from outdoor air pollution as carcinogenic to humans [12,13].

Although it was previously considered that air pollution mainly affects the lungs and cardiovascular system, recent literature has reported that it also threatens brain health, promoting Alzheimer’s disease and affecting cognitive, behavioral, and academic performances [14,15,16]. In terms of brain effects, particulate matter is the component of air pollution that appears to be the most concerning [17].

1.1. Emission Inventory from Cuenca

The municipality of Cuenca currently has about 640,000 inhabitants. It has a complex topography, with altitudes ranging from 1000 to 4000 m. a.s.l. (Figure 1). Table 1 presents a summary of the emission inventory from 2014 [4]. The total emission of NOx was 8402 t y−1, with on-road traffic (71.2%) and a power facility (18.5%) located in the northeast of the city being the most significant source. The total emission of PM2.5 was 907 t y−1, with on-road traffic (42.4%), the handcrafted production of bricks (38.5%), and the power facility (11.3%) being the most significant sources. The handcrafted production of bricks corresponds to about 600 artisanal producers, mainly located in the northwest, outside of the urban area. The power facility is also situated outside of the urban area of Cuenca.

Buses emitted 1861.2 and 87.2 t y−1 of NOx and PM2.5, respectively, representing 31.1% and 22.7% of the total on-road traffic emissions of each pollutant (Table 2). Even heavy diesel vehicles emitted higher quantities of NOx and PM2.5, compared with buses, producing 36.9% and 63.4%, respectively, of the total on-road traffic emissions of each. Gasoline vehicles emitted 30.3% and 7.0% of the NOx and PM2.5 from on-road traffic.

The total emission of non-methane volatile organic compounds (NMVOC) was 15,310 t y−1, with on-road traffic (39.6%), the use of solvents (29.7%), and vegetation (19.5%) being the most important sources (Table 1). Gasoline cars emitted 72.8% of the NMVOC from on-road traffic (Table 2), representing a priority source that needs to be controlled. NMVOC from on-road traffic includes exhaust and evaporative (diurnal emissions, running losses, and hot-soak emissions) emissions.

The number of buses considered in the emission inventory from 2014 was 2304 [4]. This quantity includes urban buses, whose total is currently 475 units. According to the Ecuadorian regulation, the public transport service comprises the following areas of operation: Urban, intraregional, interprovincial, national, and international.

The quality of hourly emission maps derived from the emission inventory from 2014 [4], which is the most recent, was verified when these emissions were incorporated into a 3D-Eulerian model for studying the influence of six planetary boundary layer schemes for modeling the air quality in Cuenca [18]. Modeling is also a powerful approach for foreseeing the effects on air quality, due to changes in the emission inventories [19], which can help define policies, programs, and projects for air quality management.

1.2. The Air Quality from Cuenca

The air quality stations are mainly located in the urban area. There is one automatic station located in the historic center (MUN station, Figure 1), which, since 2012, has monitored the short-term air quality (CO, NO2, PM2.5, and O3) and meteorology [20]. Additionally, there are about 20 passive stations for measuring monthly-mean air quality concentrations (NO2 and O3). Measurement of the air quality is based on the methods established in the Ecuadorian air quality regulation under the responsibility of the Municipality of Cuenca, which, for this purpose, is the entity accredited by the National Environmental Authority. The air quality network’s current equipment is described in the report on the air quality from 2019 [20], which corresponds to the directives established by the USA Environmental Protection Agency and European. As part of its operation, corresponding quality assurance and quality control activities are permanently performed.

From 2012 to 2019, all daily records of NO2 (maximum 1-h mean) were lower than the WHO guideline (200 µg m−3). From 2008 to 2019, the annual mean NO2 concentrations (passive stations) varied between 5.5 and 47.2 µg m−3 [20,21,22,23,24,25,26]. Annual mean NO2 concentrations higher than the WHO guideline (40 µg m−3) [11] were measured at Bomberos (BCB) and Vega Muñoz (VEG), which are microscale stations located at a street canyon supporting the high level of traffic of gasoline and diesel (buses) vehicles.

From 2012 to 2019, during fourteen days, the PM2.5 concentrations (24-h mean) were higher than the WHO guideline (25 µg m−3). The annual mean PM2.5 concentrations varied between 6.1 and 10.8 µg m−3. During four years in this period, this mean was higher than the WHO guideline (10 µg m−3, [11]).

From 2012 to 2019, the maximum 8-h mean O3 concentrations were higher than the WHO guideline (100 µg m−3) during specific days from March 2013 (8), April 2013 (5), September 2015 (2), and September 2017 (3).

Studying the growing historical dataset or air quality records promotes the understanding of the complex behavior of air pollutants in Cuenca. Based on the records from 2013 to 2015, the weekend effect (WE), which is a phenomenon characterized by increased concentrations of O3 during weekends, although the emissions of NOx and VOC are typically lower in comparison to weekdays, was identified in the urban area of Cuenca [27], suggesting the presence of a VOC-limited regime for O3 production. This finding provided the first insights into the influence of decreased on-road traffic emissions during weekends.

1.3. Actions for Controlling Air Pollutant Emissions

One of the most relevant controls of air pollutant emissions in Cuenca is the technical vehicular revision (RTV, due to its acronym in Spanish). According to the RTV regulation, it is mandatory that vehicles running in Cuenca must demonstrate each year that their exhaust emissions are lower than the levels established in the national regulation as a requirement to allow their use. Currently, through the RTV, CO and HC emissions from gasoline cars and the opacity of diesel vehicle emissions are measured. Today, NOx emissions from on-road traffic are not controlled.

Another component currently affecting air pollutant emissions is the operation of an electric tram, conceived as the new core of the public transportation system of Cuenca that aims to solve the problems associated with on-road traffic. The building of this facility began at the end of 2013. However, different problems and conflicts have appeared related to restricted mobility and effects on local commercial activities [28]. After several years of delay, the electric tram began to work during the time of writing this manuscript. The electric tram alleviates the air pollutant emissions along its route, which includes the historic center. However, the displaced buses will move their emissions to new routes.

In the future, under the framework of the Ecuadorian energy efficiency law [29], all vehicles incorporated into the public transportation system must be electric by 2025. The shift from diesel to electric buses will eliminate or reduce the exhaust emissions from diesel buses, decreasing, as a consequence, the NOx and PM2.5 emissions.

1.4. The Forced Lockdown Owing to COVID-19

To reduce the spread of COVID-19, several measures, such as lockdowns, quarantine, stay at home, and transportation restrictions were applied world-wide. The corresponding effects on air quality have begun to be reported from different regions. Nakada and Urban (2020) [30] reported drastic reductions in NO, NO2, and CO in Sao Paulo (Brazil), although an increase in O3 concentrations. Jia et al. (2020) [31] reported an insignificant impact on reducing air pollution in Memphis (U.S.A.). Sicard et al. (2020) [32] reported increased O3 concentrations in four European cities (Nice, Rome, Valencia, and Turin) and Wuhan (China). Otmani et al. (2020) [33] reported reductions in PM10, SO2, and NO2 in Salé (Morocco).

In Ecuador, based on the infected people and the pandemic declaration by WHO, the government declared (decree 1017) the exception status on 16 March 2020 [34]. One of the measures of this status was a restriction on mobility. During the following days, on-road traffic and other activities notably reduced, therefore decreasing the emission of air pollutants.

Although the exception status was officially maintained in Cuenca until 24 May 2020, some activities restarted on 17 May 2020 [35]. On 25 May 2020, the status was relaxed, alleviating the restriction of on-road traffic and other activities, and allowed buses employed for regional transportation to reactivate their service. Since 01 June 2020, urban buses in Cuenca have returned to service.

The air quality records from the exception status provide a unique opportunity to learn and appreciate the potentiality for air quality improvement as a consequence of the decrease in activities, such as on-road traffic.

This contribution explores the following issues of the air quality in Cuenca:

  • Verification of the presence of the WE in Cuenca after 2015;

  • The effects on air quality due to the future shift from diesel to electric buses;

  • The air quality during the COVID-19 lockdown, and its comparison to previous weeks and years;

  • A holistic analysis of these interrelated components to identify insights for air quality management.

2. WE in Cuenca

In agreement with the results from 2013 to 2015 [27], from 2016 to 2019, the mean-daily profiles of CO, NO2, and PM2.5 showed lower concentrations on Saturdays and Sundays, compared to weekdays. However, O3 profiles were higher. Figure 2 depicts the profiles from 2018. The profiles of other years presented similar configurations.

Figure 2. Mean-daily profiles from 2018: (a) CO, (b) NO2, (c) PM2.5, and (d) ozone (O3).

From 2013 to 2019, the increase in the maximum 8-h mean O3 concentrations of Saturdays and Sundays compared to weekdays varied between 2.6% and 11.8% and 5.6% and 15.8%, respectively (Figure 3). Although we limited our analysis to the yearly period, our results confirm the presence of the WE in the urban area of Cuenca, where on-road traffic is the most relevant air pollutant source. More insights can be drawn in the future, through an analysis of the historical records per season or month.

Figure 3. Increase in the maximum 8-h mean O3 concentrations from Saturdays and Sundays compared to weekdays. Period of 2013 to 2019.

Diesel vehicles, representing 10.8% of the total fleet from Cuenca, reduce their activity during weekends. Therefore, significant reductions in NOx and PM2.5 emissions take place on weekends compared to weekdays. The lower activity of gasoline vehicles, which cover 89.2% of the fleet, during weekends, mainly decreases the emissions of CO and NMVOC. Therefore, the decrease of CO, NOx, and PM2.5 emissions during weekends produced, on average, lower concentrations of these pollutants (Figure 2). Other sources, such as small industries, also reduce their emissions during weekends, but the decrease in on-road traffic is more significant.

3. Shift from Diesel to Electric Buses

At the location of the MUN station, differences between the simulated scenarios (DB - EB) showed decreases in CO (between 0.00 and 0.14 mg m−3, median 0.02 mg m−3), NO2 (0.8 to 16.4 µg m−3, median 7.1 µg m−3), and 24-h mean PM2.5 (0.2 to 1.8 µg m−3, median 0.9 µg m−3) concentrations. However, the maximum 8-h mean O3 increased (1.1 to 8.0 µg m−3, median 3.5 µg m−3) (Figure 4).

Figure 4. Modeled concentrations from September 2014 for the scenarios DB (diesel buses) and EB (electric buses). (a) Maximum 8-h mean CO, (b) maximum 1-h mean NO2, (c) 24 h mean PM2.5, and (d) maximum 8-h O3 mean.

At the passive stations, the results of EB compared to the DB scenario (Figure 5) showed decreases in mean-monthly NO2 (0.2 to 5.6 µg m−3, median 3.8 µg m−3), although increases in mean-monthly O3 (0.0 to 5.7 µg m−3, median 3.9 µg m−3) (Figure 5). The smallest differences, for both NO2 and O3, were computed at Ictocruz (ICT) and Escuela Héctor Sempértegui (EHS), which are passive stations located in the south and north, respectively, in terms of the consolidated urban area of Cuenca (Figure 1), and, therefore, are only influenced by on-road traffic emissions to a small degree.

Figure 5. Comparison of modeled mean-monthly concentrations of September 2014. Horizontal axis: EB (electric buses) scenario. Vertical axis: DB (diesel buses) scenario. (a) NO2 and (b) O3. Nomenclature corresponds to the passive stations.

Figure 6 shows the modeled maps of NO2 (1-h mean at 7:00 local time (LT)) and O3 (maximum 8-h mean) concentrations of the DB and EB scenarios, from 12 September 2014. The Supplementary Materials section shows movies of the hourly modeled concentrations of NO2 and O3 from 12 September 2014, for both the DB and EB scenarios.

Figure 6. Modeled NO2 (1-h mean at 7:00 LT): (a) DB, (c) EB, and (e) DB − EB. Modeled O3 (maximum 8-h mean): (b) DB, (d) EB, and (f) DB-EB. 12 September 2014.

For the DB scenario, NOx (NO2 concentrations up to 45 µg m−3) in the urban area titrate O3, reducing its concentrations (up to about 75 µg m−3) compared to the levels computed for surrounding zones of the urban area (up about 85 µg m−3). For the EB scenario, NOx (NO2 concentrations up to 35 µg m−3) titrate to a lower degree, allowing higher O3 concentrations (up to about 80 µg m−3) in the urban area of Cuenca. When shifting to the EB scenario, modeled differences showed NO2 decreases between 3 and 15 µg m−3, and O3 increases between 3 and 7 µg m−3.

The modeled results indicate that the primary benefits of shifting from diesel to electric buses, as a mandatory action established in the Ecuadorian efficiency law, are decreases in the maximum 1-h mean NO2 (median 7.1 µg m−3) and the 24-h mean PM2.5 (median 0.9 µg m−3). However, this shift can increase the maximum 8-h mean O3 concentrations (median 3.5 µg m−3).

Apart from decreasing their short-term concentrations, lowering the NO2 and PM2.5 will also reduce their annual mean levels, promoting the attainment of the WHO guidelines and the air quality regulation. We highlight the benefits of reducing air pollution and particulate matter, owing to their carcinogenicity to humans [12,13], and the effects of particulate matter on the brain, which, according to recent literature, is the component of air pollution that appears to be the most concerning [17]. The modeled results and VOC-limited regime for photochemical O3 production suggest that VOC controls should accompany future NOx reduction to avoid an increase in O3 levels in the urban area of Cuenca.

In the future, the RTV should incorporate both NOx and VOC emission controls to verify the proper condition of exhaust catalysts for gasoline cars. Additionally, the RTV should incorporate NOx and PM2.5 controls for diesel vehicles.

The direction of change in pollutants between the DB and EB scenarios was consistent with that observed during the COVID-19 lockdown. Although other sources reduced their activities, the absence of buses allowed, to a high degree, a reduction in NOx and PM2.5 in the urban area of Cuenca. This consistency supports the validity of the approach used in this contribution to assess the effects of the future shift from diesel to electric buses in Cuenca.

The modeled results provide a preliminary estimation of air quality benefits based on the assumption that all diesel buses belonging to public transportation in the future will be replaced by electric buses. An updated emission inventory and the proposal of an appropriate future electric bus fleet (electric and hybrid) configuration will refine these results. Another limitation of our study is the period employed for modeling. Although September was considered representative, it is advisable to model other months or even the entire yearly period.

Another scenario deserving exploration is the control of emissions from heavy diesel vehicles, which contributed the largest percentages of on-road emissions of NOx (36.9%) and PM2.5 (63.4%) in 2014. The effects of NMVOC controls should be explored for gasoline cars, especially for older vehicles. Due to their emissions, other sources deserving dedicated assessments are industrial activities, the power facility, and the handcrafted production of bricks.

The operation of the tram project will produce changes in the public transportation system of Cuenca. The routes of buses need to be appropriately redesigned to define the best way to incorporate them. Emissions from buses will be redistributed, alleviating their magnitude on the historic center, although moving emissions to areas under the influence of new routes.

Table 4 presents a comparison with other assessments on the influence of moving to electric vehicles. Minet et al. (2020) [43] and Soret et al. (2014) [44], although using WRF as the meteorological model, used Polair3D and the Community Multiscale Air Quality Model (CMAQ) as the chemical transport model when studying the effects on the air quality in areas of Canada and Spain, respectively. Minet et al. (2020) reported decreases in NO2 and PM2.5, although they did not focus on O3. In agreement with the tendencies of our modeled results, Soret et al. (2014) reported decreases in NO2 and PM2.5, but increases in O3. One advantage of using WRF-Chem is the possibility to apply an online approach, allowing simultaneous treatment with feedback between meteorological and air quality variables.

Table 4. Comparison with other assessments on the influence of electric vehicles on air quality.

Nogueira et al. (2019) [45] and Varga et al. (2019) [46] applied an approach based on changes in emissions when assessing the effects in São Paulo (Brazil) and Cluj-Napoca (Romania), respectively. These assessments, summarized in Table 4, reported decreases in NOx emissions.

Although the replacement of diesel buses by electric buses will reduce the emissions along the routes used by these vehicles, the generation of electricity will produce air pollution in the areas of influence of the fossil fuel power facilities belonging to the Ecuadorian mix. From 2001 to 2018, electricity came from renewable sources (43.5% to 73.6%), fossil fuels (26.2% to 52.2%), and importations (0.1% to 11.5%) [47]. Non-renewable sources include the combustion of fuel oil, diesel, naphtha, natural gas, bunker, oil, and liquid petroleum gas. The impact on air quality due to the electricity produced in Ecuador is a topic deserving of further research.

4. Air Quality during the COVID-19 Lockdown

The concentrations of CO and NO2 were lower during the COVID-19 lockdown compared to previous records from 2020 (Figure 7). The maximum 8-h mean CO mean decreased from 0.74 (median) to 0.60 mg m−3. The maximum 1-h mean NO2 decreased from 36.8 (median) to 16.3 µg m−3. The distributions of CO and NO2 during the lockdown period were statistically different, with lower levels compared to distributions from 01 January 2020 to 16 March 2020 (Table 5).

Figure 7. Air quality in Cuenca from 01 January to 16 May 2020. (a) Maximum 8-h mean CO. (b) Maximum 1-h mean NO2. (c) 24-h mean PM2.5. (d) Maximum 8-h mean O3.

Table 5. Wilcoxon tests of short-term air quality records from 2020. Distributions of records were statistically equal if p > 0.05 (green background). Distributions of records were statistically different if p < 0.05 (gray background).

Compared Periods Maximum 8-h Mean CO Maximum 1-h Mean NO2 24-h Mean PM2.5 Maximum 8-h Mean O3
Probability p
01 January to 16 March 17 March to 16 April 0.004 1.9 × 10−9 0.516 0.004
01 January to 16 March 17 March to 16 May 7.1 × 10−4 3.5 × 10−18 8.7 × 10−4 0.824

Additionally, the concentrations of PM2.5 were lower during the restriction (Figure 7). The 24-h mean PM2.5 decreased from 9.6 (median) to 5.7 µg m−3. The peak after 17 March 2020 can be associated with the arrival of volcanic ash from the Cayambe—one of the currently active volcanoes in Ecuador [48]—which produced light ash fallout in Cuenca on 24 March 2020 [49]. This peak influenced the PM2.5 records from 17 March to 16 April 2020, which showed a distribution statistically equal to records from 01 January to 16 March 2020.

During the first days of the lockdown, the O3 concentrations increased. The maximum 8-h mean O3 rose from 52.2 to 55.7 µg m−3, with the last value being the median from the first month after 17 March 2020. The median from 17 March 2020 to 16 May 2020 was 47.1 µg m−3. The distribution of O3 from 17 March to 16 April 2020 was statistically different, showing higher values compared to the distribution from 01 January to 16 March 2020 (Table 4). However, the distribution of O3 from 17 March to 16 May 2020 was statistically equal, showing similar levels to the distribution from 01 January to 16 March 2020.

The seasonal behavior of the maximum 8-h mean O3 in Cuenca shows a decrease during April and May, with the lowest concentrations during June and July (Figure 8). After this, O3 increases, typically reaching the highest values during September. Therefore, the O3 decrease during the second month of the lockdown relates to its seasonal variation. Figure 8 shows that the O3 levels during the COVID-19 lockdown were higher than the concentrations from previous years (2015 to 2019).

Figure 8. (a) Maximum 8-h mean O3 from 2015 to 2020. (b) Mean maximum 8-h O3 from 2015 to 2019 and maximum 8-h O3 from 2020. Urban area (MUN station) of Cuenca.

Figure 8 shows the mean profile (maximum 8-h mean) of O3 concentrations deduced from the records of the period 2015 to 2019 and the concentrations from 2020. The profile from 2020 shows, in general, higher concentrations compared to the mean of the previous years. From 01 January to 16 March, the O3 concentrations from 2020 were 10.0 µg m−3 (median) higher than the mean profile from previous years. During the lockdown (17 March to 16 May 2020), this difference increased to 13.9 µg m−3 (median), indicating a net increase of 3.9 µg m−3, which is consistent with the increase (3.5 µg m−3, median) obtained by modeling when assessing the air quality effects of moving from DB to EB.

Figure 9 compares the records from the lockdown to previous years. The median values of CO, NO2, PM2.5, and O3 from 2015 to 2019 varied between 0.74 and 1.24 mg m−3, 22.9 and 37.0 µg m−3, 4.2 and 9.4 µg m−3, and 32.4 and 37.3 µg m−3, respectively. During the COVID-19 lockdown, the medians of CO and NO2 dropped to 0.57 mg m−3 and 15.3 µg m−3, respectively. The PM2.5 during 2020 was 6.2 µg m−3, so it was higher than the value from 2015. However, O3 during 2020 increased to 49.8 µg m−3.

Figure 9. Air quality in Cuenca (MUN station) from 17 March to 16 May from 2015 to 2020. (a) Maximum 8-h mean CO. (b) Maximum 1-h mean NO2. (c) 24-h mean PM2.5. (d) Maximum 8-h mean O3.

The distributions of CO and NO2 during the lockdown period from 2020 were statistically different, showing lower concentrations compared to the distributions of the same period from 2015 to 2019 (Table 6). Similarly, the distribution of O3 was statistically different, showing higher levels compared to the previous years. The distribution of PM2.5 during the lockdown period from 2020 was statistically equal, only showing similar concentrations to 2016.

Table 6. Wilcoxon tests of short-term air quality and global solar radiation records from 17 March to 16 May. Distributions of records were statistically equal if p> 0.05 (green background). Distributions of records were statistically different if p < 0.05 (gray background).

The low PM2.5 median from 2015 (4.2 µg m−3) can be associated with the reduction in traffic—especially buses—in the historic center, due to activities of the construction of the electric tram. This project’s construction activities caused the closing of streets and changes in the routes of buses and limited the use of particular vehicles [28]. The operation of this project will produce changes in the public transportation system of Cuenca. At the time of writing this manuscript, the tram was being tested, and it will officially start working during the upcoming weeks.

The decrease in CO, NO2, and PM2.5 from 17 March to 16 May 2020, compared to previous weeks (01 January to 16 March 2020), was consistent with the decrease of these pollutants compared to previous years (2015 to 2019). Although other activities, such as some industries, probably reduced their activities, these changes can be associated, to a high degree, with reductions in on-road traffic. During the restriction, all types of vehicles reduced their activity. Buses did not work, and, therefore, there were essential reductions in NO2 and PM2.5.

On the other hand, the increase in O3 concentrations is consistent with the hypotheses behind the WE [50]. Among them, the results suggested that the following could have a leading role:

  • There is a VOC-limited regime, with a VOC/NOx ratio lower than 8. Under this regime, VOC limits O3 production, and NOx reduction promotes O3 production, and;
  • Less O3 is titrated because NOx emissions are lower compared to weekdays.

Other mechanisms, such as the reduction in soot, can contribute to higher O3 concentrations. More studies are required to define the participation of these and other hypotheses behind the WE in Cuenca.

Figure 10 shows the mean profiles of global solar radiation from 2017 to 2020 (MUN station), corresponding to the period 17 March to 16 May. These profiles indicate the mean levels of solar radiation from 9:00 to 16:00, representing the hours when O3 concentrations are typically higher. The profile of 2020 did not show higher values compared to previous years. The corresponding Wilcoxon tests indicated that the distributions of global radiation records from 2020 were statistically equal compared to the previous three years. These results indicate that the increase in O3 concentrations during 2020 is not related to higher solar radiation levels. Apart from changes in the emissions of precursors, another factor potentially involved is the long-range transport of O3. From 1 January to 16 May of 2020, Terra and Aqua satellites [51] identified forest fires, mainly in Colombia and Venezuela, toward the northeast of Ecuador. In addition, forest fires were mostly identified in the north of Peru and the center of Brazil. At the latitude of Cuenca, forest fires were less abundant and mainly at the center and west of South America. Although the influence of forest fires is outside the scope of this study, their occurrence from 1 January to 16 May suggests their emissions were not the leading cause of O3 increases during the COVID-19 lockdown.

Figure 10. Mean profiles of global solar radiation from 2017 to 2020 in the urban area (MUN station) of Cuenca. Period 17 March to 16 May.

The effects of the COVID-19 lockdown and modeled results presented in this contribution provide an early reference for the potential changes in the air quality of Cuenca during the next few years.

Although we focused our analyses on Cuenca, our results can act as a preliminary reference for other medium–large Ecuadorian cities, which share similar features with regards to their vehicular fleets and emission contributions [1,2].

 

This entry is adapted from the peer-reviewed paper 10.3390/atmos11090998

This entry is offline, you can click here to edit this entry!