Technologies of Combined Heat and Power Production: Comparison
Please note this is a comparison between Version 1 by Michel Feidt and Version 2 by Catherine Yang.

The combined hot heat and power (CHHP) terminology adopted nowadays is more representative than the CHP that was designated at the end of 19th century, the first combination of useful effects of the electricity production based on the thermomechanical engine industry. The two useful effects of CHHP, electricity and heat, are differentiated by priority, together with the corresponding first law efficiency expressions.

  • combines heat and power
  • trigeneration
  • environmental impacts
  • thermodynamic modelling
  • constraints

1. Gas Engine CHHP

This alternative uses an internal combustion engine fueled with natural gas or biogas.
Figure 13 illustrates the configuration of a gas engine CHHP. The engine could be fueled with natural gas from the network (at a pressure of 4 bar). Generally, the produced electricity is of low voltage or mean voltage for industrial applications (power).
Figure 13. Schematic diagram of a gas engine cogeneration unit [1].
Schematic diagram of a gas engine cogeneration unit [16].
Heat is recuperated as warm water from various heat exchangers: cooling lubricant, cooling exhaust gas (flue gases), cooling turbocharger. The main use seems to be in the tertiary domain, with 1 MW order of magnitude (building, hospital, university) [2][13].

2. Gas Turbine CHHP

Figure 24 represents such a system. The air is compressed (within the range 15 to 40 bar) in a turbocompressor, before being introduced in the combustion chamber, where it maintains the burning of liquid fuel or natural gas. After the combustion, the flue gas is expanded in the turbine coupled to the alternator to produce electricity. Part of the mechanical energy produced by the gas turbine is used to drive the compressor.
Figure 24. Scheme of a CHHP with Gas Turbine engine [3].
Scheme of a CHHP with Gas Turbine engine [17].
The exhaust gases (flue gases) are at 450–550 °C, while the combustion temperature is 850–1200 °C. Sensible heat could be recuperated in heat exchangers or within a post-combustion chamber.
Gas turbine engine CHHP is mainly used for power upper to 1 MW. Examples are available in the following sections. ThWe researchers indicate that the new tendency is to consider microturbines [4][5][6][18,19,20].

3. Diesel Engine

This CHHP configuration is interesting, due to the high value of the first law efficiency of the diesel engine over a large domain of power output, the flexibility of the fuel that can be used, and the large variety of CHHP configurations. The recuperated heat comes from three sources: (1) exhaust gases, (2) engine cooling water (around 110 °C) or low-pressure vapor (about 0.5 bar), (3) engine lubricant cooling.
The industrial use of this configuration is not so evident, but it is well-adapted for air conditioning systems. Generally, the diesel CHHP systems have a lower global first law efficiency, due to the low thermal recuperated heat associated with high mechanical efficiency.

4. Vapor Engine

This CHHP configuration uses a back pressure vapor turbine (with an exit pressure higher than the ambient one) [6][7][7,20].
Its main use is in industry where it ensures the delivery of water vapor in the networks (generally at 3 bar or 12 bar). The water vapor could be also extracted during its expansion in the turbine [6][20].

5. CHHP with Combined Cycles

In this case, there is a coupling between a gas turbine and a vapor turbine (Figure 35). The heat rejection of the gas turbine is used to produce water vapor for the vapor turbine. Many variants of this system exist [6][8][20,21].
Figure 35. Combined cycle Gas Turbine + Vapor Turbine and cogeneration [6].
Combined cycle Gas Turbine + Vapor Turbine and cogeneration [20].
The high efficiency of the conversion from chemical (fuel) energy to the electrical one implies that the rejected heat from the gas turbine tends to be low, since the main interest is to produce water vapor for industrial use.

6. External Combustion Engine CHHP

The two main types of external combustion engines are the Stirling [9][10][22,23] and Ericsson [9][22] configurations. These two cycles are also used for reverse cycle applications (cold production). Note that the Stirling configuration is present in more applications than the Ericsson one. A great advantage of these systems consists of the fact that external combustion control is easier with whatever fuel is used. Additionally, external heat source does not exclude other configurations, for example, solar ones [11][24]. Complementary references on the subject with specific configurations are given in [12][13][14][25,26,27].

7. Fuel Cells

The most common fuel cell (FC) uses the reciprocal chemical transformation of water dissociation (electrolysis of water), according to:
H 2 + 1 2 O 2 H 2 O
where H2 is the fuel, and O2 is the oxidizer.
This chemical reaction is environmentally safe because it produces only water. The fuel H2 could also be produced from natural gas, liquefied petroleum gas (LPG), or other fuels by chemical reaction with the catalysis that is used to boost the electrochemical reaction.
Globally, the electrochemical reaction produces electrical energy and heat. The first law of efficiency for electrical production is around 50%, according to the fuel cell architecture.
If H2 is produced from a hydrocarbon species, CO2 emission is identical to one of the most performant diesel engines, due to the functional temperature of FC in the range of 80 °C for PEMFC (proton exchange membrane fuel cell) and 1000 °C for SOFC (solid oxide fuel cell). However, the rejection of NOx is suppressed, as well as the sulfur oxides.
The rejected heat recovery essentially depends on the level of temperature rejection. In this respect, SOFC [15][16][28,29] could turn a gas turbine, due to their high temperature rejection, and thus improve the first law efficiency for electricity production, always with an interesting level of temperature for the remaining heat rejection.
Even if FC are well-studied, their applications seem to remain rather demonstrative projects.

8. Comparison and Some Other Possibilities

Table 13 summarizes the advantages and inconveniences of the three main configurations of CHHP, apart from industrial uses.
Table 13.
Comparison of three cogeneration systems.
Cogeneration System Gas Turbine Gas Engine Diesel Engine
  • Thermal configuration of solar CHHP, for example the dish Stirling [14][27] engine, where solar energy is the hot source ensuring heat to mechanical energy conversion,
Power range 1–230 MW 0.2–5 MW 0.15–10 MW
Fuel used Heavy oil, kerosene, biogas LPG, biogas Heavy oil, kerosene
Flue gas temperature 500–600 °C 400–600 °C 350–400 °C
Cooling water temperature - 80–90 °C 70–75 °C
Efficiency of the electricity production 25–40% 28–38% 30–45%
Total efficiency 60–85% 60–80% 40–70%
More recently, some new configurations of CHHP appear, for example, based on solar energy conversion, namely:
  • Photovoltaic and thermal conversion (PVT).
This more recent approach considers the direct conversion of radiative solar energy to electricity, while the remaining heat could be used for air conditioning (heating or cooling), as well as hot water production.
Actually, the situation is very contrasted, due to the importance of the laws and specificities of nations. In France, the cogeneration is poorly used (3% around 2000), due to the high weight of nuclear energy in the electricity production. Thereby, cogeneration is used for the industry heat network and tertiary domain (hospital, buildings, university).
In Europe, according to Cogen Europe [17][30], the cogeneration in 2000 was 10% of the total production, with 50% in industry (chemistry, paper, petroleum industry). Eurostat [18][31] provides an interesting repartition of used fuel (Figure 46) and technologies (Figure 57).
Figure 46. Use of different types of fuel [18].
Use of different types of fuel [31].
Figure 57. Electricity production distribution among different CHP systems in EU [18].
Electricity production distribution among different CHP systems in EU [31].
Figure 46 shows that the most used fuel in EU is natural gas (47%), followed by coal and derived products (14%) and renewable fuel (12%), while the weight of the other fuels is below 10%.
Figure 57 confirms that the vapor turbine is dominant in the EU, with 73% of usage, since it is present in condensation turbines (12%), back pressure turbines (30%), and combined cycles (31%).

9. Considerations Regarding Efficiencies

9.1. First Law Efficiency of CHHP

The first law of efficiency of CHHP was introduced differently, since its expression depends on the priority of the useful effect given to (i) work or (ii) heat (particularly heat networks). 
Figure 68 shows the first law efficiency values for different CHP power plants and the main cogeneration systems in EU countries, with the average of the 15 countries, followed by the distribution of each of them. It appears that the combined cycle efficiency is the highest in Denmark, Germany, Luxembourg, Sweden, and Finland, but modest on EU-15 (about 52%), while the CHHP using the back pressure turbine have the highest efficiency in Spain, France, Ireland, Italy, Netherlands, and UK, as well as an average on EU-15 (about 79%).
Figure 68. First law efficiency of different CHP systems in EU [18].
First law efficiency of different CHP systems in EU [31].
The configuration with condensation and steam extraction is less efficient, with an average of the first law efficiency about 42% for EU-15, but the criterion used is doubtful.

9.2. First Law Efficiency for Trigeneration

The general definition of the first law of efficiency in the case of trigeneration involves three useful effects:
  • Hot heat flux ,
  • Cold heat flux ,
  • Power output , with the steady-state operation assumption.
The energy rate expense is generally heat flux, . Thus, the first law efficiency expression for trigeneration is:
η I ,     t r i g e = Q ˙ H , u + Q ˙ C , u + W ˙ Q ˙ E .
The value of this efficiency is less than 1, due to the thermal losses rate of the system and rejected heat rate, . By considering these two heat rates, an equivalent expression of the first law efficiency for trigeneration results in:
η I ,     t r i g e = 1 Q ˙ R + Q ˙ L Q ˙ E .
Figure 79 illustrates a general scheme of the heat flow in a trigeneration system, starting with:
  • E—the primary heat, from the source to the system,
  • H—the hot heat delivery,
  • C—cold heat delivery,
  • R—heat rejected to the sink.
Note that the important issues associated with trigenerations are considered and discussed in [19][32].
Figure 79. Scheme of a general trigeneration configuration [19].
Scheme of a general trigeneration configuration [32].

9.3. Exergy Efficiency

The exergy efficiency indicator is a useful tool for maximizing the benefit and efficiently using the resources [20][33]. It allows us to emphasize the losses and internal irreversibilities leading to the reduction of the energy potential to produce useful effects.
It is well-known that the heat rate exergy is expressed as the product of the Carnot efficiency and the heat rate [20][33]:
E x ˙ Q = ( 1 T 0 T ) Q   ,
where T0 is the ambient temperature, and T is the temperature at which the heat transfer occurs.
Replacing the various heat rate terms in the first law efficiency (Equation (3)) with the corresponding heat rate exergy from Equation (5) provides the expression of the exergy efficiency for trigeneration:
η e x ,     t r i g e = ( 1 T 0 T H S ) Q ˙ H , u + ( T 0 T C S 1 ) Q ˙ C , u + W ˙ ( 1 T 0 T E S ) Q ˙ E ,
with THS, hot heat effect temperature > T0,
TCS, cols heat effect temperature < T0,
TES, primary heat effect temperature > THS.
This temperatures associated to the heat rates delivery are indicated by bold lines in Figure 79.