There are many types of biosensors, which cannot function without signal transducers. Currently, transmitted signals consist primarily of electrical signals, optical signals, etc (Figure 1). FNA possesses the features of strong specificity, diverse functions and stable structure. Consequently, the detection performance of the FNA biosensors has been clearly improved as compared to conventional sensors.
2. Electrochemical Functional Nucleic-Acid Biosensors
Electrochemical FNA biosensors are designed by applying FNA to an electrochemical transducer, which converts the analytical information generated by the electrochemical interaction of analytes on the electrode into measurable electrical signals
[1]. The electrochemical analysis principle used by this kind of sensor has the characteristics of reusability, high stability, and high affinity. Therefore, it is widely used to detect ions, enzymes, proteins, viruses, and cells
[2][3].
An aptamer is a kind of FNA that can be synthesized artificially in vitro. It is screened by the systematic evolution of ligands by exponential enrichment (SELEX) technology, which screens the oligonucleotide fragments that are specifically bound to the target substance from the oligonucleotide library that is synthesized in vitro
[4]. Hence, an aptamer has the benefit of customization, and can theoretically be used to detect any target. Aptamers have been widely used as an important recognition element in electrochemical sensors. Using SELEX, Zhang et al screened the H37Rv aptamer of Mycobacterium tuberculosis through SELEX, hybridized it with treated oligonucleotides (AuNPs-DNA) and fixed it on a gold electrode for the detection of H37Rv
[5]. When the test sample contains H37Rv, it can specifically bind with the target to release AuNPs-DNA, resulting in a change in the electrode conductivity and the ability to detect H37Rv. Compared with previous studies, FNA sensors can quickly detect H37Rv without culturing or special labeling. Based on a similar principle, electrochemical FNA sensors containing aptamers are also used to detect thrombin, bisphenol A, human papillomavirus, and other substances
[6][7][8].
Mucin 1 (MUC1) is an important target that is related to various cancer types, and the development of detection methods has always attracted people’s attention
[9][10]. Because surface-enhanced Raman scattering (SERS) has some problems such as poor detection specificity and high equipment requirements
[11], a team fixed the MUC1 aptamer on a special electrode that was designed as an electrochemical FNA biosensor for detecting MUC1
[12]. Compared with the SERS method, which is commonly used in hospitals, the sensor offers prominent improvements in the detection range and the detection limit. The detection range of the system is 50–1000 nM, and the limit of detection (LOD) is reduced to 24 nM. It is applied to the detection of human serum samples, and other researchers have further developed many electrochemical FNA sensors for specific tumor cell detection on this basis
[13]. Past studies have shown that carbon nanospheres (CNSs) have characteristics such as good chemical stability, bioaffinity, electrical conductivity, and non-biological toxicity
[14]. Therefore, they are considered to be ideal materials for electrochemical FNA-sensor reaction platforms. Cao et al. used the MUC1 glycoprotein, which is expressed on the surface of colon cancer DLD-1 cells, as a target to screen specific aptamers and fix them on the CNS reaction platform in order to produce a sensor
[13]. Compared with past research, this method greatly reduces the experimental difficulty and has similar detection effects
[11]. Furthermore, the CNSs used in the system are non-biotoxic materials, which indicates that this sensor has the potential to be used for real-time detection in the human body. Karpik et al. applied a similar method to design an electrochemical FNA biosensor for detecting prostate cancer cells MUC1
[15]. In the experiment, the sensor detects the MUC1 expression patterns of different prostate cancer cell line models and normal prostate cells, and is able to distinguish between normal prostate cells and different types of prostate cancer cell in clinical testing. Compared with the existing methods such as ELISA and immunoassay, the sensor can resist the interference of a variety of substances, and also has higher detection sensitivity
[16][17].
Another major type of FNA is DNAzyme, which has the ability to catalyze nucleic-acid cleavage. A detailed introduction to DNAzyme will be given later. As a result of the extraction of ores and the use of fossil fuels, heavy metal ions, as major environmental pollutants, pose serious threats to human life and health. Recent studies have shown that the electrochemical FNA biosensors developed by DNAzyme have high sensitivity and specificity for heavy metal ions, and thus, they have attracted extensive attention in the field of environmental detection
[18][19][20][21]. Tang et al. selected 8–17 DNAzyme for the specific detection of Pb
2+ [22]. Firstly, the designed substrate chain was hybridized with DNAzyme to form double stranded DNA (dsDNA). Then, DNAzyme was specifically activated by Pb
2+, which cut and released the substrate chain. Subsequently, the connection probe and signal probe, which can generate electrical signals, were added and cyclically hybridized with DNAzyme to form long DNA structures. Therefore, the long-stranded DNA formed by a DNAzyme was able to contain multiple signal probes, and thus, could significantly amplify the electrical signal. The LOD of Pb
2+ detected by the electrochemical FNA sensors was reduced to 6.1 pM, which is only one-tenth of that detected by previously examined electrochemical sensors
[23][24]. As a result of these improvements in the detection sensitivity and biocompatibility of FNA, the sensor has great application prospects in the detection of human heavy metals.
In biomedical research and food safety investigations, it is often necessary to detect many important small molecular substances, such as adenosine triphosphate (ATP), pesticide residues, etc. However, due to the weight of small molecules, the detection conditions are difficult to ensure with accuracy. By combining aptamers and DNAzyme in aptazymes, one can harness the catalytic cleavage activity of DNAzyme when it has the recognition ability of the aptamer. In addition, aptazymes will only produce catalytic activity when aptamers bind to small molecular targets and cause structural changes
[25]. Researchers used the aptamer that specifically recognizes ATP and 10–23 DNAzyme, which are sensitive to Mg
2+, to form an aptazyme
[24]. In addition, the target sequence of DNAzyme was connected with the signal probe to form a catalytic hairpin assembly (CHA). In the experiment, the ATP and Mg
2+ in the system activated the enzyme activity of aptazyme, and then catalyzed the cleavage of CHA to release DNAzyme and a signal probe. The released Mg
2+-sensitive DNAzyme continued to participate in the cutting of CHA, resulting in a large number of signal probes being released and bonding to the electrode, which caused an amplification of electrical signals. The electrochemical FNA sensors could accurately detect 0.6 nM ATP in the human serum samples.
3. Fluorescent Functional Nucleic-Acid Biosensors
Fluorescent FNA biosensors are composed of a recognition part, a transformation part, and a fluorescent material part. As FNA can be modified by fluorescent groups and quenchants and has strong a recognition ability, fluorescent FNA biosensors are widely used and comprise many types
[26]. However, they are mainly divided into labeled fluorescent FNA biosensors and label-free fluorescent FNA biosensors
[27].
The first report on labeled fluorescent FNA biosensors was published in 2000
[28]. The researchers used a TAMRA fluorophore and a Dabcyl quencher to label the dsDNA, which was composed of a substrate chain hybridized with 8–17 DNAzyme. In a natural state, the quenching effect of the quencher leads to the low-fluorescence reaction of the system. However, in the presence of Pb
2+, in the above study, 8–17 DNAzyme was activated to cut the substrate chain and then release the substrate chain, which was labeled with fluorescent groups, resulting in the enhancement of the fluorescence signal. Finally, the concentration of Pb
2+ was obtained by detecting the fluorescence signal intensity, but this method required the labelling of two groups on the enzyme chain, resulting in high experimental cost and time. In recent years, sensors for the detection of metal ions have been further developed. Fluorescein amidite (FAM) was used as a fluorescent group to label the substrate chain, and then hybridized with DNAzyme to form a bulged structure
[29]. Then, ethidium bromide (EB) was embedded into the bulged structure as a quencher to quench the fluorescence signal. When DNAzyme was activated by Pb
2+, the substrate was cut to release EB, so that the fluorescence signal was restored. The sensors made according to this fluorescence turn-on principle did not require the modification of the quencher on the DNAzyme, so the experimental cost was reduced and time was saved.
In contrast, the FNA sensors designed according to the opposite principle of fluorescence turn-off also showed good performance. Zhang et al used FAM to modify the substrate chain, and then hybridized it with UO
22+-sensitive DNAzyme to form dsDNA
[30]. In the experiment, the fluorescently labeled single-stranded DNA (ssDNA) released by the activated DNAzyme was adsorbed on a special reaction platform, causing the fluorescence signal to be quenched. Compared with the common colorimetric sensor, the FNA sensors designed using this method showed a 200-fold increase in sensitivity to UO
22+. In addition, the researchers also designed a labeled fluorescent FNA sensor for the detection of H
2S in the air based on the principle of fluorescence turn-off
[31]. Up to now, a variety of metal ions have been detected by labeled fluorescent FNA sensors
[32][33][34][35][36][37][38].
Label-free fluorescent FNA biosensors are usually designed by using intercalating fluorescent dyes to intercalate FNA, and then changing the fluorescence response through the interaction of the target with FNA, the most common of which is the G-quadruplex structure of FNA
[39]. Guanine nucleotides can form a tetrad structure through hydrogen bonds, and multiple such tetrad structures can be stacked to form a G-quadruplex structure
[40]. This type of sensor has a similar accuracy to the labeled type, but does not affect the functional activity of FNA. Therefore, it is widely used in many fields. Zhu et al. designed a dsDNA containing a G-rich substrate chain and a DNAzyme that is sensitive to UO
22+, and used the nucleic-acid-intercalating dye SYBR Green I (SG I) for fluorescent labeling. When DNAzyme was not activated, the fluorescent dye was embedded in dsDNA and showed high fluorescence intensity. When UO
22+ activated the DNAzyme, the substrate chain was cleaved to form a G-quadruplex, releasing fluorescent dyes, which resulted in a decrease in the fluorescence signal. Compared with the labeled type, the sensors had a similar sensitivity while reducing the difficulty of production
[41]. Researchers also applied this principle to the detection of Pb
2+ environmental samples
[42]. As we all know, metal ion pollution in environmental pollution has always been one of the main threats to people’s health and safety. Therefore, a variety of types of label-free fluorescent FNA biosensors have developed that can be used for the detection of K
+, Na
+, Ba
2+, Ir
3+, Hg
2+, Tl
+, Tb
3+ and other metal ions
[43][44][45][46][47][48][49]. The G-quadruplex sequence and the metal cation will form a stable G-quadruplex structure. Screening of the aptamer with the G-quadruplex sequence (oligo-3), which has high selectivity for K
+, can be applied to K
+ detection
[43]. It is then necessary to select the fluorophore which binds to the generated G-quadruplex. When K
+ is present, the aptamer is induced to form a G-quadruplex and binds to a fluorophore to generate a high fluorescence reaction. In addition, the G-quadruplex can also be used for Hg
2+ detection. Hg
2+ produces a T-Hg
2+-T mismatch with the DNA sequence
[47]. Therefore, the G-quadruplex structure is destroyed, and the fluorescence is turned off. Highly specific aptamers with G-quadruplex sequences and fluorescent groups can be selected for the detection of other metal cations.
In addition, food safety is another major factor affecting human health; therefore, the development and application of label-free fluorescent FNA sensors are also of great value. Taghdisi et al. used aflatoxin B1 (AFB1)-specific aptamers containing a G-quadruplex-forming sequence to form a hairpin structure and used N-methyl mesoporphyrin IX (NMM) as a fluorescent reporter group
[50]. It was found that when the aptamer binds to AFB1, it causes the hairpin structure to disintegrate and produce a G-quadruplex structure, and then combine with NMM to produce a strong fluorescent signal. The sensor was able to detect 30–900 pg/mL AFB1 within 30 min. In addition, it was successfully applied in the detection of actual products such as grape juice.
In recent years, in vivo imaging of tumor cells using fluorescent FNA biosensors has gradually become a research hot spot. This technological breakthrough has significantly promoted the development of the biomedical field. Studies have shown that quantum dots (QDs) are a type of nanomaterial with light stability and small size, and are good tools for cell imaging
[51]. Chu et al. combined prostate-specific membrane antigen (PSMA) aptamers with luminescent QDs for prostate cancer cellular imaging
[52]. The conjugate can target and label living cells, which has important application prospects in the research of human prostate cancer. However, the use of QDs is limited because of their potential biological toxicity and background interference. Therefore, in recent studies, researchers have used carbon dots (CDs) as fluorescent signals to replace QDs. CDs, as a novel member of carbon family, are a type of nanomaterial with good biocompatibility, low biotoxicity and facile preparation. They have become more and more popular in the field of biological detection
[53]. CA125, which is an important characteristic antigen of ovarian cancer, was chosen by one group of researchers as the detection target. The team prepared CA125 aptamer-functionalized CDs (CDs-Apta) for cellular imaging of ovarian cancer cells
[54]. The experimental results show that the specificity and sensitivity of this method are significantly improved compared with other studies
[55][56]. In addition, the cell survival rate was good after 48 h of treatment, indicating very low biotoxicity and the potential for use in patient bioassays. FNA biosensors for tumor cell imaging are being developed towards non-toxicity, high precision and high flexibility. In the future, they will play a key role in tumor mechanism research and drug development.
4. Colorimetric Functional Nucleic-Acid Biosensors
The colorimetric FNA biosensors are based on the color change reaction of a certain compound, which causes the color of the entire system to change, and the result of the change can be obtained using a spectrophotometer or by visual observation to obtain a quantitative or qualitative result
[57]. In order to solve the problem of rapid and high-precision detection of target substances without special instruments, this type of sensor has received extensive attention. Li et al. used aptamers that specifically recognize miRNAs and G-rich DNA (GDNA) to form a hairpin structure
[58]. When the aptamer is combined with miRNA, GDNA can combine with hemin to form a G-quadruplex/hemin DNAzyme. This is a common enzyme mimic with horseradish peroxidase (HRP) activity, which can be used to catalyze the conversion of colorless 2,2′-azino-bis (ABTS
2−) into green ABTS
−. This design can achieve rapid and highly sensitive detection of miRNA.
Moreover, colorimetric FNA biosensors also show great application potential in the detection of human pathogens. In a recent study, researchers screened out DNAzymes activated by
Helicobacter pylori (HP) protein and then hybridized the urease-linked substrate strand with the DNAzyme strand
[59]. In the experiment, HP protein activated DNAzyme to cleave the substrate chain so that urease was released into the system, and then urease entered the detection area, which contained urea and phenol red, to hydrolyze urea into ammonia, causing pH changes and discoloration of the area. The sensor uses paper as a reaction platform and can be applied to detect HP in human feces, which has important application value in terms of protecting people’s intestinal health. The developed HP detection technologies are mainly divided into invasive and non-invasive tests
[60][61][62]. Invasive tests include endoscopic biopsy-based histology, followed by a rapid urease test and molecular PCR. This will consume a lot of time and entail significant costs. Among the non-invasive tests, the urea breath test (UBT) and the stool antigen test are commonly used
[63]. However, the result of the non-invasive test is not very reliable and may be affected by urease produced by other bacteria in the digestive tract.
In summary, colorimetric FNA biosensors effectively solve the problem of restricting experimentation due to equipment requirements in the fields of clinical diagnosis and food testing.