Sweat as a Biological Fluid of Alcohol Detection: History
Please note this is an old version of this entry, which may differ significantly from the current revision.

The continued focus on improving the quality of human life has encouraged the development of increasingly efficient, durable, and cost-effective products in healthcare. Over the last decade, there has been substantial development in the field of technical and interactive textiles that combine expertise in electronics, biology, chemistry, and physics. Most recently, the creation of biosensors capable of quantifying biometric data in biological fluids to detect a specific disease or the physical condition of an individual is being studied. The ultimate goal is to provide access to medical diagnosis anytime and anywhere. Presently, alcohol is considered the most commonly used addictive substance worldwide, being one of the main causes of death in road accidents. Thus, it is important to think of solutions capable of minimizing this public health problem such as the case of alcohol biosensors using sweat as biological fluid of detection, which is reviewed in this study.

  • road accidents
  • alcohol
  • biomarkers
  • biosensor
  • biomimetic

1. Sweat Composition

Recently, there has been considerable interest in the diagnosis of sweat, that is, in the use of sweat as a non-invasive alternative to blood tests to provide data on physiology, health and human performance. Although blood remains the preferred standard in clinical, analyses of other common body fluids, such as sweat, are gaining relevance. The compositions of sweat and blood are osmotically related. Hence, similarly as with blood, the content of certain metabolites in sweat can directly reflect a disease or a physical condition. Most publications on sweat diagnosis are primarily focused on the development of skin-interfaced platforms capable of capturing and performing quantitative measurements of sweat chemistry, such as biosensors capable of detecting biomarkers like lactate [1], glucose [2], cortisol [3], adrenaline, dopamine, phenolic compounds [4][5], and electrolytes [6][7][8] in order to provide new tools for healthcare monitoring. Thus, it is essential to identify the known and unknown factors regarding the composition of sweat to generate hypotheses and guide future research in diagnosis.
Sweat is composed of 99% aqueous solution and a mixture of many chemicals in varying concentrations, including micronutrients (e.g., K+, Ca2+, Mg2+, Fe2+ and vitamins); metabolites (e.g., lactate, ammonia, urea, bicarbonate, amino acids, ethanol) as well as proteins and hormones such as cortisol. These compounds are mostly released through the eccrine glands. These glands are composed of a secretory spiral where sweat is generated, and a dermal duct, which is responsible for transporting sweat through the from the epidermis to the skin surface [9]. During this process, the referred chemicals are incorporated into sweat by passive diffusion and transdermal migration, as it shown in Figure 1.
It must be noticed that humans have between 2 and 5 million eccrine sweat glands throughout the body, which are more densely aggregated in certain regions [10]. In general, it is usually easier detect some substance in sweat in areas of the skin with higher amounts of eccrine glands like palms and sole of foot, as they allow the analysis of larger volumes.
The correlations of chemical molecular levels in blood and sweat have been reported, such as glucose [11], lactate [12], ethanol [13], ammonia and urea [14]. These studies concluded that, to some extent, blood analysis can be replaced by sweat analysis.
Moreover, the final composition of sweat is influenced by several factors such as extracellular concentrations solute, residual sweat, sweat flow rate, sweat gland metabolism in each area of skin, skin contamination and sample evaporation. Thus, despite all the non-invasive advantages, the diagnosis of human sweat on the skin surface of an individual may have some inconveniences such as low sample volumes, contamination of the skin and the possibility of evaporation. These challenges must be studied considering some factors such as:
  • Sweat Released Rate: According to a study, the average sweat rate during physical activity is approximately 0.5 µL/min/cm2 with a range of 0.17 to 1.21 µL/min/cm2 [15]. When considering all areas of the skin, the resting sweat rate should be less than the sweat rate during exercise by 40% [15]. Thus, here can say that, on average, about 1.2 µL/min/cm2 corresponds to the amount released by an individual at rest. However, it’s important to note that the palm region has a skin with higher density of sweat glands, adding ease of collection [16]. Furthermore, in addition to liquid phase sweat detection (sensible sweat), there are some devices capable of measuring volatile organic compounds (VOCs) released through skin (insensible sweat), that have shown high correlation with blood alcohol levels [17][18].
  • Contamination: Chemicals absorbed by the skin through different cosmetics can be released through sweat and interfere with detection capability. Thus, sweat should be quickly absorbed by the detection platform to avoid contamination from the skin. A way to prevent different components from interfering with the intended analyte reading is, for example, the use of a semipermeable membrane, responsible for allowing only certain substances to pass through it by diffusion [9].
  • Sample Evaporation: it is necessary to have a fast detection in order to obtain reliable results, as evaporation acts quickly on small volumes of exposed sweat, which may change the concentration of its constituents [9].

2. Alcohol in Sweat: Correlation between Sweat and Blood

Blood and urine are the most prevalent and used conventional biological matrices for carrying out alcohol consumption analyses. The use of these biological matrices requires the use of complex techniques such as gas chromatography [19]. Although this method produces extremely accurate blood acohol concdentration (BAC) measurements, it uses invasive data collection methods, and it cannot be determined on site. Later, the measurement of alcohol concentration from exhaled air was developed, as it demonstrated a good correlation to blood alcohol levels.
As an alternative to blood and breath tests, sweat analysis has the advantage of containing compounds capable of serving as biomarkers without the need for standard invasive testing methods. In addition, through the analysis of the alcohol content in sweat, the results cannot be altered in the same way as with the breathalyzer method, so there is a lower risk of tampering by interference with foods/drugs taken orally. Circulating in the blood stream, ethanol diffuses into surrounding tissue, including the skin, being the amount of direct excretion of unchanged alcohol in sweat approximately 1% [20]. This allows the concentration of ethanol in sweat to be used as an indicator of the presence of ethanol in blood. However, as alcohol does not diffuse through the skin instantly, there may be a slight delay in the corresponding values of its concentration in blood and sweat.
The development of alcohol detection devices through sweat and further comparative between ethanol concentrations obtained in sweat and blood has been already addressed in literature. One of the first studies was carried out by Buono [13], where it was possible to demonstrate that the ethanol concentration in sweat is highly correlated with blood ethanol concentration. In that study, sweat and blood samples were collected from ten volunteers 1, 2 and 3 h after the ingestion of approximately 13 mmol of ethanol diluted in a 15% fruit juice solution over a period of 30 min. These variables revealed a Pearson correlation of 0.98 indicating a linear variation [21] Furthermore, the slope obtained was 0.81, meaning that the ethanol concentration in blood corresponded to 81% of the ethanol concentration of ethanol in sweat. During this period, Kamei et.al [22] proposed a novel instrumentation capable of estimating and comparing the ethanol concentration in sweat and blood. This proposal consisted in a sampling probe attached directly on the surface of the skin, where it is possible to measure the rate of sweat released, as well as the ethanol concentration in sweat. Three volunteers participated in this study, where each drank 700 mL of beer with 5% ethanol in a period of 2 to 5 min. During this process, the concentration of ethanol in blood was simultaneously measured through of an authorized clinical method. From the obtained results it was possible to conclude that the concentrations of ethanol in blood and sweat reached the maximum peak at almost the same time, demonstrating a very similar profile after ingestion of alcohol by humans. Other scientific studies, carried out by Nyman and Palmlov have reported that the concentration of ethanol in sweat is about 15% higher than the concentration of ethanol in blood [23] The common conclusion in all these studies concerns the high correlation between these concentrations (Pearson correlation indexes very close to 1). Moreover, they also conclude that the concentration of ethanol in sweat is higher than found in blood by approximately 15% [13][22][23]
It is important to highlight that for a good evaluation there are some factors that can influence the action of alcohol such as body weight, dose of ethanol ingested and metabolic rate. Studies have shown that body weight has little effect on the time interval between peak BAC and TAC (transdermal alcohol concentration) and for a specific dose, the peak alcohol increases as body weight decreases. Regarding the rate of metabolism, the lower the metabolic capacity, the higher the concentration of ethanol present in the body, resulting in a longer peak delay [20].

3. Flexible Biosensors to Detect Alcohol in Sweat

A biosensor is a device capable of providing biometric data, including the concentration of certain chemical substances present in biological fluids, such as alcohol in sweat.
The interest in wearable biosensors has increased recently, since biosensor’s flexibility has begun to attract considerable attention to the scientific community. Transdermal biosensors have been designed in tattoos/skin patches, shirts, and other flexible substrates such as woven fabrics or polymer-based manufactured fibrous structures.
In the past decade, the field of wearable and flexible biosensors has seen substantial development, and most applications are health-related through the transduction of physical parameters. The development of biosensors has brought a new era of advances in science. Of the electrochemical devices under evaluation, only the SCRAM™ unit is commercially available at present, but the technology underlying the devices mentioned above are already commercially viable. The SCRAM™ is designed as an ankle bracelet with a sensor compartment and a digital signal processing compartment, which transmits the collected data to an in-home modem [24]. This platform has been implemented by law enforcement personnel to monitor individuals with alcohol-related offenses. The WrisTASTM corresponds to the first wrist bracelet designed for use in medical settings to control alcohol abstinence [25]. In 2015 a new generation wrist-worn bracelet for alcohol monitoring with came out, and connects via Bluethooth to an app on a user smartphone [26]. Since then, wearable sensing devices have been designed to detect alcohol detection through flexible platforms, such as temporary tattoos [27].
As previously mentioned, in recent years, some alcohol detection systems have been developed in the analysis of sweat, such as attempts to obtain non-invasive, continuous, and discrete alcohol sensors. Currently, flexible electrochemical biosensors are the most commonly used in biofluids analysis, where its principle is based on the reaction of the bioreceptor (enzymes, antibodies; etc.) with the target analyte in order to obtain an electric response (current, potential difference).

A wearable electrochemical biosensor capable of monitoring alcohol consumption by detecting and quantifying Ethyl Glucuronide (EtG), was developed in 2016 [28]. To this end, in this study, two coplanar sensors were developed with gold (Au) and zinc oxide (ZnO) integrated into polyimide (PI) by bonding. Up until then, it was possible to detect EtG in sweat using complex techniques such as gas chromatography associated with mass spectrophotometry, however they were deemed and inadequate processes for on-site diagnosis, not allowing real-time feedback from the person [19][29]. Thus, this project allowed to monitor alcohol consumption by detecting EtG in sweat through wearable biosensors, reacting with colour change through a LED in the presence of EtG in human sweat. Regarding to the results obtained, the ZnO sensor showed a detection capability in the concentration range of 0.001–100 μg/L up to 4 h. On the other hand, the Au sensor demonstrated an ability to detect EtG in the concentration range of 1–10,000 μg/L up to 9 h [28]. The authors concluded that the biosensor could detect ingestion of alcohol up to 11 standard drinks in the United States for a period of 4 to 9 h [28]. In 2019, the chemist Jan Halamék and his team at the University of Albany in New York aimed at developing a new non-invasive method to assess the level of alcohol content in the blood of an individual based on the presence of ethanol in sweat. To do so, 26 volunteers of different ages, genres and eating habits participated [15]. This detection system uses a polyethylene strip composed of two enzymes, alcohol oxidase, and horseradish peroxidase in order to relate blood ethanol concentrations with sweat ethanol concentrations from a series of biochemical reactions. As soon as the strip meets the skin, the chemical reaction of the two enzymes with the ethanol in sweat produces a colour change, resulting in a blue-green tone, increasing its intensity with the increasing concentration of ethanol in the analysis sample. The study allowed the quantification of ethanol in the human sweat of 26 volunteers as how to prove that as the individual ingests alcoholic drinks, the concentration of ethanol in sweat increases linearly with the concentration of blood alcohol levels [15]. Some research groups have integrated the pilocarpine iontophoresis process into the biosensors to stimulate sweating and monitor alcohol concentration in induced sweat. This is a transdermal administration of pilocarpine followed by amperometry detection of ethanol. In the study developed by Jan Halámek the same process was only used to obtain the amount of sweat needed for the initial proof of concept corresponding to 8μL, where concentrations were added millimolar ethanol (Mm) of 0; 10.85 and 17.35 corresponding to 0% BAC; 0.05% BAC and 0.08% BAC, respectively [15]. Kim et al. developed a flexible portable biosensor consisting of a temporary tattoo, which adhered to the skin in order to accurately measure the level of blood alcohol through ethanol concentrations in human sweat [25]. This biosensor integrates a substance capable of inducing sweat through iontophoresis, pilocarpine, enabling the amperometry detection of ethanol in sweat by the enzyme AOx. Regarding the results, the biosensor exhibited a highly selective and sensitive response to ethanol. The bodily effects in humans have shown significant differences in the current response before and after alcohol consumption, reflecting increased levels of ethanol in sweat after alcohol consumption. The device was considered more effective in relation to the Breathalyzer method, since it avoids possible inaccuracies caused by changes in temperature, humidity, environmental factors such as alcoholic vapors or such as foods/drugs taken orally, resulting in a lower risk of tampering [27]. A summary of the flexible biosensors discussed above is given in Table 2.

 

This entry is adapted from the peer-reviewed paper 10.3390/bios12040252

References

  1. Teymourian, H.; Moonla, C.; Tehrani, F.; Vargas, E.; Aghavali, R.; Barfidokht, A.; Tangkuaram, T.; Mercier, P.P.; Dassau, E.; Wang, J. Microneedle-Based Detection of Ketone Bodies along with Glucose and Lactate: Toward Real-Time Continuous Interstitial Fluid Monitoring of Diabetic Ketosis and Ketoacidosis. Anal. Chem. 2020, 92, 2291–2300.
  2. Martín, A.; Kim, J.; Kurniawan, J.F.; Sempionatto, J.R.; Moreto, J.R.; Tang, G.; Campbell, A.S.; Shin, A.; Lee, M.Y.; Liu, X.; et al. Epidermal Microfluidic Electrochemical Detection System: Enhanced Sweat Sampling and Metabolite Detection. ACS Sens. 2017, 2, 1860–1868.
  3. Sekar, M.; Pandiaraj, M.; Bhansali, S.; Ponpandian, N.; Viswanathan, C. Carbon fiber based electrochemical sensor for sweat cortisol measurement. Sci. Rep. 2019, 9, 403.
  4. Rahman, M.M. Selective capturing of phenolic derivative by a binary metal oxide microcubes for its detection. Sci. Rep. 2019, 9, 19234.
  5. Rahman, M.M.; Karim, M.R.; Alam, M.M.; Zaman, M.B.; Alharthi, N.; Alharbi, H.; Asiri, A.M. Facile and efficient 3-chlorophenol sensor development based on photolumenescent core-shell CdSe/ZnS quantum dots. Sci. Rep. 2020, 10, 557.
  6. Rahman, M.M.; Khan, S.B.; Gruner, G.; Al-Ghamdi, M.S.; Daous, M.A.; Asiri, A.M. Chloride ion sensors based on low-dimensional α-MnO2–Co3O4 nanoparticles fabricated glassy carbon electrodes by simple I–V technique. Electrochim. Acta 2013, 103, 143–150.
  7. Sekine, Y.; Kim, S.B.; Zhang, Y.; Bandodkar, A.J.; Xu, S.; Choi, J.; Irie, M.; Ray, T.R.; Kohli, P.; Kozai, N.; et al. A fluorometric skin-interfaced microfluidic device and smartphone imaging module for in situ quantitative analysis of sweat chemistry. Lab Chip 2018, 18, 2178–2186.
  8. Sempionatto, J.R.; Martin, A.; García-Carmona, L.; Barfidokht, A.; Kurniawan, J.F.; Moreto, J.R.; Tang, G.; Shin, A.; Liu, X.; Escarpa, A.; et al. Skin-worn Soft Microfluidic Potentiometric Detection System. Electroanalysis 2019, 31, 239–245.
  9. Bariya, M.; Nyein, H.Y.Y.; Javey, A. Wearable sweat sensors. Nat. Electron. 2018, 1, 160–171.
  10. Legner, C.; Kalwa, U.; Patel, V.; Chesmore, A.; Pandey, S. Sweat sensing in the smart wearables era: Towards integrative, multifunctional and body-compliant perspiration analysis. Sens. Actuators A Phys. 2019, 296, 200–221.
  11. Moyer, J.; Wilson, D.; Finkelshtein, I.; Wong, B.; Potts, R. Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes. Diabetes Technol. Ther. 2012, 14, 398–402.
  12. Sakharov, D.A.; Shkurnikov, M.; Vagin, M.; Yashina, E.I.; Karyakin, A.; Tonevitsky, A. Relationship between Lactate Concentrations in Active Muscle Sweat and Whole Blood. Bull. Exp. Biol. Med. 2010, 150, 83–85.
  13. Buono, M.J. Sweat Ethanol Concentrations are Highly Correlated with Co-Existing Blood Values in Humans. Exp. Physiol. 1999, 84, 401–404.
  14. Alvear-Ordenes, I.; García-López, D.; de Paz, J.A.; González-Gallego, J. Sweat lactate, ammonia, and urea in rugby players. Int. J. Sport. Med. 2005, 26, 632–637.
  15. Hair, M.E.; Gerkman, R.; Mathis, A.I.; Halámková, L.; Halámek, J. Noninvasive Concept for Optical Ethanol Sensing on the Skin Surface with Camera-Based Quantification. Anal. Chem. 2019, 91, 15860–15865.
  16. Toma, K.; Suzuki, S.; Arakawa, T.; Iwasaki, Y.; Mitsubayashi, K. External ears for non-invasive and stable monitoring of volatile organic compounds in human blood. Sci. Rep. 2021, 11, 10415.
  17. Høiseth, G.; Morini, L.; Polettini, A.; Christophersen, A.; Mørland, J. Ethyl Glucuronide in Hair Compared with Traditional Alcohol Biomarkers—A Pilot Study of Heavy Drinkers Referred to an Alcohol Detoxification Unit. Alcohol. Clin. Exp. Res. 2009, 33, 812–816.
  18. Junghanns, K.; Graf, I.; Pflüger, J.; Wetterling, G.; Ziems, C.; Ehrenthal, D.; Zöllner, M.; Dibbelt, L.; Backhaus, J.; Weinmann, W.; et al. Urinary ethyl glucuronide (EtG) and ethyl sulphate (EtS) assessment: Valuable tools to improve verification of abstention in alcohol-dependent patients during in-patient treatment and at follow-ups. Addiction 2009, 104, 921–926.
  19. Jenkins, A.J. Drug Testing in Alternate Biological Specimens; Humana Press: Totowa, NJ, USA, 2008.
  20. Webster, G.D.; Gabler, H.C. Feasibility of transdermal ethanol sensing for the detection of intoxicated drivers. Annu. Proc. Assoc. Adv. Automot. Med. 2007, 51, 449–464.
  21. Schober, P.; Boer, C.; Schwarte, L.A. Correlation Coefficients: Appropriate Use and Interpretation. Anesth. Analg. 2018, 126, 1763–1768.
  22. Kamei, T.; Tsuda, T.; Mibu, Y.; Kitagawa, S.; Wada, H.; Naitoh, K.; Nakashima, K. Novel instrumentation for determination of ethanol concentrations in human perspiration by gas chromatography and a good interrelationship between ethanol concentrations in sweat and blood. Anal. Chim. Acta 1998, 365, 259–266.
  23. Nyman, E.; Palmlöv, A. The Elimination of Ethyl Alcohol in Sweat1. Skand. Arch. Physiol. 1936, 74, 155–159.
  24. Barnett, N.P.; Tidey, J.; Murphy, J.G.; Swift, R.; Colby, S.M. Contingency management for alcohol use reduction: A pilot study using a transdermal alcohol sensor. Drug Alcohol Depend. 2011, 118, 391–399.
  25. Marques, P. Evaluating TransdErmal Alcohol mEasuring dEvicEs Final Report. 2007. Available online: www.nhtsa.dot.gov (accessed on 13 December 2021).
  26. (PDF) In Vivo Evaluation of BACtrack® Skyn: A Discrete Wrist-Worn Transdermal Alcohol Monitoring Device Marketed to the Public. Available online: https://www.researchgate.net/publication/356696470_In_vivo_evaluation_of_BACtrackR_Skyn_a_discrete_wrist-worn_transdermal_alcohol_monitoring_device_marketed_to_the_public (accessed on 1 April 2022).
  27. Christie, G.; Gual, A.; Nicola, M.; Davis-Martin, R.E.; Alessi, S.M.; Boudreaux, E.D. Alcohol Use Disorder in the Age of Technology: A Review of Wearable Biosensors in Alcohol Use Disorder Treatment. Front. Psychiatry 2021, 12, 642813.
  28. Selvam, A.P.; Muthukumar, S.; Kamakoti, V.; Prasad, S. A wearable biochemical sensor for monitoring alcohol consumption lifestyle through Ethyl glucuronide (EtG) detection in human sweat. Sci. Rep. 2016, 6, 23111.
  29. Caravati, E.M.; Anderson, K.T. Breath Alcohol Analyzer Mistakes Methanol Poisoning for Alcohol Intoxication. Ann. Emerg. Med. 2010, 55, 198–200.
More
This entry is offline, you can click here to edit this entry!