Immune checkpoint-based treatment increases the hope among the cancer patients and especially those who did not respond to more established treatments. Currently, the surface markers, programmed death-1 (PD-1) and CTLA-4 are well known for their function in the immune system, as well as their role in cancer as theranostic applications. PD-1 and CTLA-4 are two major checkpoints approved by the FDA for immune checkpoint blockade therapy. Similarly, other checkpoints, including TIM-3, BTLA, and LAG-3, are under active investigation as potential biomarkers for cancer theranostics. These immune checkpoints can be detected on tumor cells and in the tumor microenvironment (TME) through traditional tissue biopsies and IHC as well as via biosensors. Although these biomarkers are potentially for the detection of cancer, the developmental status of biosensors designed to detect these immune checkpoint markers is still at an early stage.
1. Immune Checkpoints as a Marker for Cancer Diagnosis
1.1. T-Cell Immunoglobulin and Mucin Domain-3 (TIM-3)
TIM-3 is part of the TIM family and is a receptor found on interferon-γ-producing CD4+ and CD8+ T cells
[1]. Initially, TIM-3 was considered primarily as a co-inhibitory checkpoint; a protein that is co-regulated and co-expressed alongside PD-1, LAG-3, and TIGIT
[2]. Later, TIM-3 emerged as a co-stimulatory checkpoint depending on the cell type on which it is expressed and the immune response. It is also involved in T-cell exhaustion and therefore found in tumors
[3]. In a study of leukocytes from peripheral blood mononuclear cells, the level of TIM-3 expression was significantly higher in the CD4+ and CD8+ T cells of ovarian cancer patients. CD4+ T-cells displayed further elevation of TIM-3 in ovarian cancer recurrence, suggesting TIM-3 as a biomarker for early detection as well as detection of recurrence
[4].
TIM-3 upregulation in CD4+ and CD8+ peripheral T cells was found to correlate with the presence of osteosarcoma. The level of TIM-3 expression also increased with tumor stage and metastasis, and higher TIM-3 levels were associated with worse overall survival. Such findings suggest TIM-3′s value as a diagnostic and prognostic marker for osteosarcoma
[5]. In hepatocellular carcinoma, TIM-3 expression is induced by other cytokines located in proximity in the tumor microenvironment (TME). However, TIM-3 expression, along with the expression of other T cell exhaustion markers such as PD-1 and CTLA-4, is lower in the non-tumor microenvironment (NTME) and the peripheral blood than the TME
[6]. The variation in expression of TIM-3 in the TME and NTME presents a challenge for using immune checkpoints to detect cancer non-invasively.
1.2. B- and T-Lymphocyte Attenuator (BTLA)
BTLA is a lymphocyte inhibitory receptor found on B-, T-, and other mature lymphocyte cells. BTLA regulates the immune system by inhibiting T cell reactions and restricting cytokine production and creates a tumor microenvironment that suppresses immune responses
[7]. Reports indicating high BTLA expression were found in gastric cancer, pancreatic cancer, and chronic lymphocytic leukemia (CLL)/small lymphocytic leukemia
[8]. However, this upregulation does not correlate to the presence of BTLA in the bloodstream. For example, a higher gene transcript level is observed in CLL patients. BTLAs were detected in low level peripheral blood B cells and normal BTLA levels were detected on T cells. Even in-vitro stimulation resulted in lower levels of BTLA expression on B and T lymphocytes
[9].
Different stages of B and T cells developed from bone marrow, which include pro-B/T, pre-B/T and immature B/T cells, each express unique marker. T cells are activated by B cells and further divided into T-helper and T-regulatory cells. In 1994, the number of B-cells were determined using piezoelectric sensors by immobilizing anti-B cells on the surface electrode
[10]. However, capturing B-cells at high accuracy requires sensitive biosensors to obtain an amplified signal. T-cell lymphocytes CD4+ detection using nano based biosensors was explored recently by Carinelli et al. using magnetic particles
[11]. Here, isolation of CD4+ cells were captured magnetically via anti-CD4+ using magnetic particles
[11]. Similarly, single wall carbon nanotubes-based detection coupled with electrochemical biosensor for the detection of CD4+ using with a limit of detection at 1 × 10
2 cells mL
−1 [12]. Chen and his coworkers developed a rapid assay biosensor to detect dynamic T-cell activation using nanoparticles, wherein, polyaniline fibers coated with gold nanoparticles detected multiple immunosensing markers such as CD69, CD25, and CD71 with specific anti-CD molecules. Time dependent activation of immune markers were captured with an LOD of 1 × 10
4 cells mL
−1 [13]. Hence, understanding the role of T-cell immuno-sensors at high LOD is important to reveal the immune inhibition of activated drugs.
1.3. Immune Markers in Serum
Immune markers serve as potential prognostic biomarkers in serum and could have significant predictive power of disease progression in personalized medicine. While some immune checkpoints can be detected on peripheral blood cells (e.g., PD-1) and others (PD-1, PD-L1, LAG-3, and TIM-3) can be detected in serum due to ectodomain cleavage. This section reviews such potential immune markers for the serum.
1.4. Lymphocyte-Activation Gene 3 (LAG-3)
A disintegrin and metalloproteinase domain-containing protein (ADAM) such as ADAM-10 and ADAM-17 cleave the extracellular domain of LAG-3
[14]. Higher levels of serum LAG-3 (sLAG-3) were found to correlate with earlier stages of non-small cell lung cancer. Serum of patients with stage III and IV cancer had lower levels of sLAG-3 comparatively
[15]. Contrastingly, when serum sLAG-3 levels were assessed in gastric cancer patients, individuals with gastric cancer were found to have sLAG-3 levels of 247.52 ± 51.28 ng/mL while healthy individuals had sLAG-3 levels of 869.46 ± 64.35 ng/mL. Additionally, sLAG-3 was found to have a greater sensitivity and accuracy in comparison to other serum biomarkers for gastric cancer such as CEA. sLAG-3 had a sensitivity of 88.60% and an accuracy of 90.65% when evaluated at a threshold value of 378.330 ng/mL. On the other hand, CEA had a sensitivity of 56.20% and an accuracy of 68.61% at a threshold value of 21.755 ng/mL
[16]. Measures of soluble LAG-3 in serum have prognostic value, for example, high levels of soluble LAG-3 in some subsets of breast cancer correlate with disease-free, metastasis-free, and overall survival
[17].
1.5. PD-1
Serum PD-1 or sPD-1 (along with sPD-L1) is elevated in the serum of melanoma patients in comparison to healthy blood donors
[18]. Higher sPD-1 levels are also found in non-small cell lung carcinoma (NSCLC), diffuse large B-cell lymphoma (DLBCL), chronic lymphocytic leukemia (CLL), nasopharyngeal carcinoma (NPC), HCC, pancreatic adenocarcinoma, and advanced rectal cancer
[19]. Additionally, sPD-1 and sPD-L1 can be used to predict the outcome of certain immunotherapies, such as anti-PD-1 treatment. A threshold of 500 pg/mL was used to differentiate progression-free survival rates, because of the finding that high baseline serum sPD-1 levels were associated with poor survival
[18]. Similarly, serum sPD-1 and sPD-L1 levels were significantly elevated in triple-negative breast cancer patients prior to neoadjuvant chemotherapy. However, patients who responded well to the treatment (as observed through complete or partial remission) had decreased serum sPD-1 and sPD-L1 levels compared to those who had a poor response to the treatment
[20].
1.6. PD-L1
The soluble programmed-death ligand 1 (aka PD-L1) is an immune biomarker that can potentially be used for early cancer diagnosis research due to its important role in cancer immunoregulation. The PD-L1 marker essentially binds to its receptor of PD-1 and partakes in pleiotrophic signaling pathways. When PD-L1 binds to the PD-1, there is a halt in the T cells going out to kill the foreign antigens. Thus, studies have shown that the inhibition of this interaction between the PD-L1 marker and the receptor PD-1 can result in drastic reduction of tumor growth and promote antitumor immunity. Thus, it is important to detect the concentrations of the PD-L1 marker in blood. However, it is difficult to quantify the concentration of PD-L1 marker in blood due to signal sensitivity at low concentrations.
Localized surface plasmon resonance (LSPR) biosensors enable one to improve the sensitivity of the signal at low concentrations of PD-L1 using metal nanoparticles
[21]. The detection of PD-L1 can be seen through the wavelength shift in the biosensor where the anti-sPD-L1 antibodies get immersed and localized with the gold nanoparticles in the biosensor. In this study, gold nano-shells were developed with LSPR at NIR region around 1600 nm to detect PD-L1. At different serum media, the biosensor showed high specificity to PD-L1 with a sensitivity of 1 pg mL
−1. Thus, gold nano shells-based detection of PD-L1 show high sensitivity compared to other conventional techniques like ELISA, IHC and PCR. PD-L1 undergoes proteolytic cleavage by ADAM 10 and ADAM 17 in breast cancer, resulting in a ~37 kDa fragment that can be detected in the media
[22][23]. sPD-L1 is elevated in patients with papillary thyroid cancer (PTC) compared to healthy patients. Serum sPD-L1 levels were found to be 0.37 ng/mL in healthy individuals and 0.48 ng/mL in cancer patients. Furthermore, higher sPD-L1 levels were indicative of shorter disease-free survival, suggesting the value of sPD-L1 as a prognostic marker of PTC
[24]. Even in primary central nervous system lymphoma, serum sPD-L1 levels (0.429 ng/mL) were higher than those in healthy individuals (0.364 ng/mL). Higher sPD-L1 levels resulted in more frequent relapse (78% of the study participants) than the lower sPD-L1 levels (50%)
[25].
ADAM 10 and ADAM 17 are also major target of TIM-3 that result in soluble TIM-3 (sTIM-3)
[26]. Serum sTIM-3 is found to be higher in patients with osteosarcoma when compared to patients with benign tumors and the control group (14.4 ng/mL ± 2.9 vs. 10.3 ng/mL ± 1.7 vs. 6.3 ng/mL ± 1.9). Benign tumors also displayed higher sTIM-3 levels than the control, suggesting a possibility for early detection for prevention
[27]. Additionally, elevated sTIM-3 levels were also associated with hepatocellular carcinoma (HCC). The control group had a mean serum sTIM-3 level of 2.64 ± 0.32 pg/mL while patients with HCC had a mean serum sTIM-3 level of 3.57 pg/mL ± 0.22
[28].
2. Biosensors for Cancer Markers and Immune Checkpoint Detection
Biosensors that have been used in the detection of cancer and immune checkpoint markers include electrochemical and colorimetric biosensors. Most of these biosensors share the following characteristics: consumer friendly, easy to use systems, moderate cost, low turnaround time for the results, and minimal sample size required for testing. However, when compared to detecting markers in samples with low concentrations these biosensors are not as sensitive or specific in comparison to the SPR biosensors
[29][30]. Furthermore, these types of sensors can only be used once or a limited number of times, reducing their value for conducting multiple runs.
PD-1 and PD-L1 are known
[31][32] to be independent prognostic factors for several tumor associated markers for immunotherapy. Kruger et al. quantified sPD-1 and sPD-L1 in pancreatic cancer serum with ELISA using the human PD-1 antibody duo sets for ELISA development
[33]. Reporting on immune check point of therapy with PD-L1 alone is insufficient and showed poor outcome in pancreatic cancer. For example, higher concentrations of PD-L1 and PD-1 were identified in 41 patients to test for advanced stages of carcinoma. Further studies are required to understand the correlation between the two prognostic factors for immune check point blockade therapy. Similarly, a multiplex immunoassay detection (8-color flow cytometry) method was developed using cryopreserved samples of healthy human donors to determine the level of CD8+ and CD4+, for early cancer diagnosis
[34]. Upon stimulation of T cell lymphocytes, measurement of upregulated soluble isoforms of LAG-3, TIM-3, CTLA-4, and PD-1, as detected in flow cytometry, directly correspond to treatment response.
2.1. Biosensors for Detection of Multiple Cancer/IC Markers
Multiplexed immune checkpoint biosensor (MICB) development is progressing rapidly due to their high specificity and selectivity
[35]. Multiplex biosensors require small volumes of sample to diagnose the disease and work simultaneously to detect multiple immune checkpoints. The parallel detection device is growing as it can be potentially translatable for routine clinical applications. However, with these sensors, the analyte tends to take longer to bind with the cell surface without the use of nanofluidic mixing. Hence, these sensors are time consuming and generate a response slowly. For example, a droplet loaded in the electrode can detect the PD-L1 marker and can run multiple samples at once (28 for the multiplexed biosensor on the PD-L1 marker)
[36]. Advanced versions of multiplexed electrohydrodynamic biosensors have shown improved performance for biomarker detection
[37][38]. However, many of the multiplexed lateral flow nanosensors display this limitation. Additionally, getting and visualizing the target alone for these sensors is also difficult as there are many non-specific interferences displayed in the system. Based on the applications and sample results, biosensors can be broadly classified into two types: (a) high sensitivity and specificity at the cost of a complex system (SPR and multiplexed biosensors) and (b) easy to use and cost and time effective, but not possessing high sensitivity and specificity (colorimetric and EC biosensors).
Another MICB developed by Wuethrich et al. detects soluble PD-1, PD-L1, and LAG-3 in parallel in liquid biopsies, using as little as a single sample drop of approximately 20 µL volume per target immune checkpoint
[36]. MICB utilizes a microfluidic sandwich immunoassay with high-affinity yeast cell-derived single chain variable fragments (ScFvs) as well as alternating current electrohydrodynamic in-situ nanofluidic mixing. The high-affinity yeast cell-derived ScFvs are an alternative to the use of monoclonal antibodies and polyclonal antibodies, which are costly and have a limited shelf life. High-affinity yeast cell-derived ScFvs provide longer shelf life without sacrificing specificity and can be mass-produced for a lower cost. The nanofluidic mixing stimulates immune checkpoint interactions with the biosensor while diminishing non-target sensor binding, providing greater specificity for immune checkpoint capture.
MICB has ability to analyze 28 samples in less than two hours. To understand the ability for MICB to detect soluble PD-1, PD-L1, and LAG-3 in liquid biopsies, various concentrations of immune checkpoints were spiked into diluted human serum. While the assay was able to detect a differentiable signal response from the samples with the immune checkpoints, fortified samples had a concentration equal to the prognostic cut-off, which may differ from the threshold for cancer detection
[36].
2.2. Exosome Biosensor
Exosomes are the key players in communication at the intercellular level through surface biomarkers. For instance, exosomal proteins are fundamental in cancer development, drug resistance, and differentiation etc
[39]. Expression of PD-L1 in exosomes is a biomarker that is overly expressed in lung tumors. Hence, many exosomal proteins that include exosomal immune markers like PD-L1, can be promising cancer biomarkers. In a recent study, researchers constructed a compact surface plasmon resonance biosensor that detects exosomal PD-L1 and EGFR
[40]. Looking at the different serum samples of patients with lung cancer, researchers used this biosensor to determine the specificity and sensitivity of the biomarker in these samples.
This biosensor worked through optical resolution using laser beams. Essentially, two laser beams were used in which one allowed for the SPR to interact with the exosomal proteins on the surface of the sensor. The other beam was used as reference, and the two photodetectors quantified the exosomal proteins by magnifying the intensity of the initial beam and the reflection beam. Overall, in terms of results, the SPR biosensor was much more effective in detection of exosomal PD-L1 in comparison to conventional methods like ELISA
[41]. First and foremost, the study depicts that the SPR biosensor was very accurate and effective in detecting the PD-L1 in serum samples including that of a Stage III lung cancer patient; however, the method of ELISA was unable to detect PD-L1 in general. These serum samples were all 50 microliters. Additionally, through these biosensors, researchers proposed that the exosomal PD-L1 can be a biomarker (although this still needs to be confirmed through larger sample sets) for lung cancer diagnosis as the SPR biosensor detected much more exosomal PD-L1 in lung cancer patients compared to the normal controls
[40]. The sensitivity and specificity of the SPR biosensor was much greater than the ELISA testing as the ELISA test could not detect any of the PD-L1 in serum samples in which there was a very low abundance of the exosomal PD-L1.
2.3. Biosensors for Overall Cancer Immunotherapy
Biosensors could play a pivotal role in augmenting cancer immunotherapy for treatment monitoring and evaluation of disease condition. For example, several study results revealed that the nano biosensor can be utilized cytokine secretion from individual cells for hours
[42]. A specific biosensor is combined with a gold nanohole array sensor and a microfluidic-based system for accurate depiction and detection of cytokine secretion within a cell-to-cell basis. Additionally, some groups have worked on detection of the IL-2, IFN-γ, and TNF-α cytokines using gold nanorod-based biosensors
[43]. Using these different types of sensors, researchers showed that immunoanalysis could be done on a smaller volume of analyte and a shorter timeframe than conventional ELISA methods
[44]. Thus, these nanomaterial-based biosensors can be employed for more versatile applications than detection of a major immune checkpoint marker such as PD-L1.
2.4. Biosensors for CRISPR
Clustered regularly interspaced short palindromic repeats (CRISPR/Cas) based biosensors have also become more important for rapid detection of nucleic acids, exosomes, tumor DNAs, etc. CRISPR/Cas sensors use Cas effectors to cleave a specific DNA sequence. One of the main effectors, Cas9, has become well known due to its effective ability of editing genomes, identifying nucleic acids, and regulating transcription
[45][46]. Specifically, Cas9 uses single guide RNA to help target a specific double-stranded DNA and cleave it for the purpose of selective genome editing
[45][46]. In addition, the usage of nuclease-deactivated Cas9 can allow for binding and rebinding to the targeted double-stranded DNA, which is essential as fluorescent enzymes can be fused to the DNA to allow for detection of specific nucleic acid sequences due to the fluorescence and light emission
[29][30]. This fusion of integrating Cas9 with a fluorescent enzyme was instrumental for researchers to detect DNA sequences of the American Zika virus. Other types of Cas effectors such as Cas12 and Cas13 have also been explored. Wherein, Cas12 effector is extremely important due to its ability to detect single-stranded DNA, which adds more to the detection of the different nucleic acids rather than focusing only double-stranded DNA with Cas9 effector. However, the main reason researchers have started to focus on CRISPR/Cas-based biosensors for cancer detection is due to the Cas13a effector. This effector works with the collateral cleavage activity of single-stranded RNAs. When there is a specific RNA of interest, the Cas13a effector cleaves RNA, the collateral cleavage of the reporter RNA (reRNA) which allows for the detection of the RNA with accurate quantification
[31]. This effector is key for recognition of many miRNAs which can be either up-regulated or down-regulated. Hence, by being able to detect levels of miRNAs rapidly and effectively, this field of CRISPR/Cas-based biosensing is becoming a hot topic and displays promise for the early detection of cancer. However, one key limitation is that these biosensors involve sophisticated systems to run a tedious process to function fully
[45][46]. Hence, reading these biosensors and their detection of the specific analyte requires well-trained professionals to understand the process and readout. Furthermore, the sensitivity of the biosensors is relatively low when compared to the other amplification methods
[45][46]. Though many researchers are working on CRISPR/Cas-based biosensors, none of them could meet the needs of in vivo testing due to low sensitivity detection. Despite these issues, there is potential for the development of biosensor based on the Cas13a effector and the collateral cleavage activity detection
[47].
2.5. Biosensors for ICB: Advantages and Limitations
Globally, the market size and demand for biosensors is rapidly increasing
[46]. In 2026, the market size is expected to expand to about 37 billion dollars for all the different types of biosensors (electrochemical, FRET, piezoelectric, optical, etc.). However, improvements in biosensors are still a challenge because of the low concentration of biomarkers expressed over the cells. Nanomaterials-based detectors have the potential to amplify the signals with limit of detection at pico- or femtomolar concentration. In addition, the COVID-19 pandemic in 2020 has shown us the potential need of biosensors. Hence, in this review we have outlined current improvements and strategies in biosensors over the last decade for biomedical applications have been explored.
The detection of immune checkpoints via liquid biopsy presents an attractive option for early cancer detection. Currently, immune checkpoints are not widely used for diagnostics. Instead, they are utilized as prognostic markers for cancer and as predictors for the success of various immunotherapies. The biosensors proposed in recent years from the studies of Xu et al.
[48] showcase the various advantages of using these biosensors for detecting small concentrations of PD-L1. For the quantification of different immune checkpoint markers like PD-L1, the studies showcased the limitations of ELISA and immunohistochemistry. For example, with ELISA, it is difficult to detect PD-L1 with very small concentrations. However, PD-L1 in multiple types of serum media is found in very small concentrations and thus, ELISA becomes extremely inaccurate in many situations. Immunohistochemistry is also an employed method that becomes very time-consuming and has very complex procedures. With these surface plasmon resonance-based biosensors and the multiplex biosensor, the studies show the simple-to-use nature of the biosensors, the very high specificity and sensitivity of the sensors, as well as their time and cost effectiveness. One way to ensure cost-effectiveness is a sensor that uses very cheap single-chain variable fragments from yeast cell lines in replacements of the very costly antibodies of the different immune checkpoint proteins that are used in the conventional methods.
Biosensors have been developed to detect the concentrations of the immune checkpoint markers in serum samples e.g., PD-L1
[36], but other potential IC markers can be identified through same approach. These biosensors demonstrated a few unique features with fine differences in the benefits and limitations of using one over the other.
Table 1 list the various advantages and disadvantages of these biosensors that are reported in the relevant literature
[21][36][29][30][38]. Developments in surface plasmon resonance (SPR)-based biosensors development, especially for the detection of immune checkpoint markers in early detection of cancer, have progressed well due to several key advantages
[21][40].
Table 1. Biomarkers and associated limits of detections (LOD) when using biosensors.
Cancer Type |
Biomarker |
Diagnostic (D) Prognostic (P) |
LOD/mL |
References {LOD References} |
Tumor-Associated Antigens |
Breast |
HER-2 ECD, CEA CA15-3 |
D/P |
2 ng, 5 ng, 21.8U |
[47][49][50][51] {[52][53][54]} |
Ovarian |
CA125, CA15-3 |
D |
35 U, 12U |
[55][56][57][58][59], {[56][58]} |
Pancreatic |
CEA |
P |
5 ng |
[60] {[61]} |
CA19-9 |
D |
37U |
[62] {[63]} |
CA125 |
D/P |
35U |
[64][65] {[66]} |
Gastric |
CEA, HER-2 ECD |
P |
5 ng, 24.75 ng |
[60][67] {[67][68]} |
NSCLC |
CEA |
P |
3–5ng |
[69][70] {[70]} |
Endometrial |
CA 125 |
D/P |
17.8U |
[71][72] {[71]} |
Colorectal |
CEA |
D/P |
5ng |
[73] {[74]} |
Prostate |
PSA |
D |
2.5–4 ng # |
[75] {[76]}[77] |
Immune Checkpoint Markers |
Primary central nervous system lymphoma (PCNSL) |
PD-L1 |
D/P |
0.43 ng |
[24] {[25]} |
NSCLC, DLBCL, CLL, NPC, HCC, ADR, PAC, HCC, Melanoma |
PD-1 |
P |
ND, 500 pg 1 |
[18][19] {[18]} |
Breast, Gastric |
LAG-3 |
P |
120 pg, 378.3 ng |
[15][16] {[16][18]} |
PAC, Osteosarcoma, Ovarian |
TIM-3 |
P, D/P, ND |
3 ng, 14.4 ng |
[4][5][27][28] {[27][28]} |
LSPR biosensors show very high specificity and sensitivity (LOD: 1–5 pg/mL) for the immune checkpoint marker PD-L1
[21]. Furthermore, these biosensors are highly selective for the marker in comparison to the normal detection methods, e.g., immunohistochemistry, and can be integrated with a label-free detection system. Most of these sensors use fluorescent labeling or some other type of labeling approach to analyze the different analytes. However, the detection of analytes was required with different types of media which resulted in non-specific binding and high background signals. In addition, receptor labeling requires extensive time, effort, and optimization for the development of accurate biosensors for reproducible results. These limitations do limit the biosensors’ usability. However, there is no additional labeling step required since this biosensor relies on physical properties of the analyte immobilized on a surface. Hence, these biosensors do not require nearly as much labor nor time to work effectively. Additionally, the biosensors allow for real time detection of the analyte as the analyte is localized into a compact surface; thus, there is no alteration of binding sites which could possibly occur with biosensors that require a labeling system.
SPR-based devices can cause configurational changes of the marker or analyte being detected by biosensors
[78]. These biosensors use a mechanism of action where the analyte gets immobilized on the surface, often causing lower binding affinities due to the configurational changes of the immobilized receptor which, can cause the analyte binding ability and make it hard to detect the analyte accurately. SPR biosensors detect the marker or analyte by a change in wavelength with the aid of gold nanomaterials. Using these nanomaterials and immobilizing the analyte is a complex system to use for the commercialization of the product on a large scale.
This entry is adapted from the peer-reviewed paper 10.3390/bios11120500