Adaptive Façades: Comparison
Please note this is a comparison between Version 2 by Jason Zhu and Version 7 by Jason Zhu.

Adaptive building envelope systems can manage energy and mass transformation between indoor and outdoor environments, which contributes to the achievement of environmental benefits via reducing energy consumption and greenhouse gas emission while maintaining human comfort and well-being.

  • adaptive façade
  • evaluation
  • control

1. Introduction

Constant anthropogenic activities have contributed significantly to the early effects of global greenhouse gas (GHG) emissions, causing the world to experience climate change [1]. In particular, rapid urbanization and population growth have significantly increased global energy consumption, making GHG emission reduction necessary [2]. By 2035, worldwide energy consumption is projected to increase by 50% compared to the levels in previous decades. It is essential to reduce energy consumption from the source to address these serious problems. Buildings account for approximately one-third of both global energy consumption and GHG emissions [3]. Without transformation, the construction industry will likely be unable to restrain growing global energy demand. The European Union aims to achieve 32.5% energy efficiency by 2030 and a carbon-free building stock by 2050 [4]. To realize these goals, European legislation covers aspects ranging from building performance assessment and building automation to incentives (e.g., financing schemes) to assist building performance improvement and decarbonization. For instance, European COST Action TU1403 (Adaptive Façade Network (2014–2018)) encourages researchers to improve and create envelope technologies to control energy consumption [5], because building envelopes, as the interfaces affecting the energy exchange between indoors and outdoors, can be utilized effectively to improve the performance of buildings and achieve decarbonization. Walls, roofs, floors, and other components comprise building envelopes, and the wall is the main part of the envelope structure [6]. The International Energy Agency [7] has reported that huge energy savings can be realized by employing building envelopes, especially in energy-efficient building renovation, because many buildings will continue to be used after 2050.

To address energy performance challenges with regard to buildings, the role of building façades is being expanded from conservation to adaptation [8]. This expansion is occurring because adaptive façades (AFs), compared with traditional static façades, combine active and passive measures and can adapt to changing indoor and outdoor conditions in the short or long term by changing their shape [9] and color [10][11], among other aspects, to reduce the net energy consumption and ensure occupant comfort and well-being [8]. The current research on AFs is carried out from the following aspects.

To address energy performance challenges with regard to buildings, the role of building façades is being expanded from conservation to adaptation [8]. This expansion is occurring because adaptive façades (AFs), compared with traditional static façades, combine active and passive measures and can adapt to changing indoor and outdoor conditions in the short or long term by changing their shape [9] and color [10,11], among other aspects, to reduce the net energy consumption and ensure occupant comfort and well-being [8]. The current research on AFs is carried out from the following aspects.

Façades were first classified using the term ‘AFs’ in 2007 [12], but the term ‘adaptive’ has not been used uniformly across research thus far [13]. Based on Tabadkani et al. [14], AFs in this paper include the following typologies, ‘active’ [15], ‘interactive’ [16], ‘responsive/media’ [17], ‘dynamic’ [18], ‘kinetic’ [19], ‘switchable’ [10], ‘smart’ [20], ‘intelligent’ [21][22], and ‘biomimetic’ [23][24][25] (Figure 1); it is not possible to distinguish every category completely, as there is considerable overlap between each type. However, some studies, such as [26], show that AFs are abreast of these categories rather than included within them.

Façades were first classified using the term 'AFs' in 2007 [12], but the term 'adaptive' has not been used uniformly across research thus far [13]. Based on Tabadkani et al. [14], AFs include the following typologies, 'active' [15], 'interactive' [16], 'responsive/media' [17], 'dynamic' [18], 'kinetic' [19], 'switchable' [10], 'smart' [20], 'intelligent' [21,22], and 'biomimetic' [23,24,25] (Figure 1); it is not possible to distinguish every category completely, as there is considerable overlap between each type. However, some studies, such as [26], show that AFs are abreast of these categories rather than included within them.

 

Figure 1. Main characteristics of adaptive façade typologies.

Figure 1. Main characteristics of adaptive façade typologies.

In terms of designs, based on functions, AFs can be classified as warm or cold façades. Based on structures, building adaptive skins can be identified as single or double façades. The concept of a warm skin is similar to that of a single skin, involving the use of insulation material on the inside or outside of the skin to improve the energy efficiency of the building. A cold skin is similar to a double skin, where a space is created between two layers of skin to allow air circulation and thereby ensure ventilation and cooling [27]. AFs can be designed according to the above basic principles. Then, combined with the needs of building users, AFs can be designed considering four aspects: indoor heating and cooling comfort, visual light comfort, natural air circulation, and energy consumption reduction. Further, from a technical perspective, AFs can be divided into artificial technical and natural ecological skins.

Many techniques related to AFs can be acquired in the market [8][28], but the performance evaluation of such technologies has been limited [29]. The lack of consistent performance evaluation criteria seriously hinders AFs’ widespread use and market penetration [29]. The salient feature of this type of façade is the variability of its responses to indoor and outdoor changes; however, many variables such as climate factors and occupant requirements exist, and integrating multiple variables for performance evaluation is challenging [25][30][31]. In addition, AFs can be created by changing shape and physical properties, but the performance evaluation of the combination of these features is still under investigation [24]. There are three main methods of performance measurement: digital simulation-based [32], experiment-based [30][33], and occupant survey-based [34] measurements. When new or renovated AFs are designed, the performance must be assessed by conducting building performance simulations (BPSs) during the design phase [35]. Compared with experimental methods, simulations are more widely available and are cheaper. However, the predicted values often differ considerably from the actual values due to the diversity of variables [28]. Further, the unique physiology, psychology, and roles of occupants result in considerable variations in survey results [36]. Therefore, performance evaluation needs to involve the entire AF life cycle and include all stakeholders [28] to drive market share gains.

Many techniques related to AFs can be acquired in the market [8,28], but the performance evaluation of such technologies has been limited [29]. The lack of consistent performance evaluation criteria seriously hinders AFs' widespread use and market penetration [29]. The salient feature of this type of façade is the variability of its responses to indoor and outdoor changes; however, many variables such as climate factors and occupant requirements exist, and integrating multiple variables for performance evaluation is challenging [25,30,31]. In addition, AFs can be created by changing shape and physical properties, but the performance evaluation of the combination of these features is still under investigation [24]. There are three main methods of performance measurement: digital simulation-based [32], experiment-based [30,33], and occupant survey-based [34] measurements. When new or renovated AFs are designed, the performance must be assessed by conducting building performance simulations (BPSs) during the design phase [35]. Compared with experimental methods, simulations are more widely available and are cheaper. However, the predicted values often differ considerably from the actual values due to the diversity of variables [28]. Further, the unique physiology, psychology, and roles of occupants result in considerable variations in survey results [36]. Therefore, performance evaluation needs to involve the entire AF life cycle and include all stakeholders [28] to drive market share gains.

When a device is designed to perform with responsive, superimposed control systems, it can be actuated to control indoor comfort and realize environmental benefits. The objective of employing AFs is to achieve a sustainable method of dynamically responding to the fluctuating external and internal environments in order to create a comfortable space for users [36] without affecting energy consumption, which is usually supported by a control system. The term ‘degree of adaptability’ was created to describe the complexity of AFs [37]. The degree of adaptability is determined by the number of possibilities; in other words, the more possible the AF state is, the more conducive it is to improving the indoor environment and comfort. The concept of module AFs has also been introduced, where an AF is composed of multiple modular units. Each unit has different states and can change them independently, and the diversity of unit quantity and states leads to diverse AF unit combination methods. Further, accurate modular unit control can improve AF adaptability.

The discussion in most relevant literature is based on one aspect, such as designs [6,13,14,20], performance evaluation [38,39,40], or control systems [41], or two aspects, such as designs and performance evaluation [25,42], designs and control systems [43], or control systems and performance evaluation [44]. Although researchers have realized that performance evaluation should be conducted throughout the life cycles of AFs and that all stakeholders should be considered [28], there is currently no clear and consistent evaluation standard to conduct performance evaluation and improve market share.

The discussion in most relevant literature is based on one aspect, such as designs [6][13][14][20], performance evaluation [38][39][40], or control systems [41], or two aspects, such as designs and performance evaluation [25][42], designs and control systems [43], or control systems and performance evaluation [44]. Although researchers have realized that performance evaluation should be conducted throughout the life cycles of AFs and that all stakeholders should be considered [28], there is currently no clear and consistent evaluation standard to conduct performance evaluation and improve market share. Therefore, this paper is structured around three key aspects—designs, performance evaluation, and control systems—to explore and elucidate the factors hindering AF development via literature review and representative practical projects. Figure 2 shows the main structure of this paper.

The remainder is organized as follows. Section 2 describes the variable structures and materials, production properties, environmental benefits, and applications of AFs. Section 3 discusses the importance of performance evaluation, reasons for unsympathetic evaluation criteria, existing assessment criteria, and performance evaluation tools. Section 4 exhaustively explains the features of control systems, including influencing factors, methods, modes, strategies, and implementations. Section 5 addresses the ongoing challenges and trends.

Figure 2. The main structure of this paper.

Figure 2. The main structure of this entry.

2. Designs

There are two main trends in AF design: artificial technology and natural ecology. Further, the directions can be divided into four types: innovation of the variable structure with parameter logic, development of variable materials for micro characteristics, utilization of building technology for resource production, and application of vertical greening ecology based on environmental benefits. In addition, to provide a more comprehensive and objective understanding of the development status and research frontiers related to AF design worldwide, practical projects, research prototypes, parts, and other related typical cases were sorted based on the four abovementioned aspects.

Figure 3. Practical AF projects.

Figure 3. Practical AF projects.

2.1. Innovation of the Variable Structure with Parameter Logic

2.1.1. Outer Variable Shading System

As a common type of variable structure, an outer variable shading system has both practical and aesthetic properties as well as strong topological ability and applicability. The primary purpose of regulating solar radiation and indoor lighting is to prevent glare. It is characterized by dynamic responses to environmental changes to avoid the compromise of the traditional shading system in terms of the environmental regulation effect.
Sauerbruch and Hutton designed the Cologne Oval Office in 2010 [451]. The sunshade that rotates along the vertical axis in this building regulates light and solar radiation, while also serving as a façade element to fulfil the architectural aesthetic needs. Al Bahar Tower in Abu Dhabi, completed in 2012 [462], draws inspiration from natural forms, creatively using a hexagonal folding variable structure to adjust solar radiation and reduce indoor glare and programming to control the variable shading system to respond to the changes in solar radiation and incidence angle throughout the year. Thus, the solar radiation heat gain and building air conditioning demand are reduced by 50%. In 2016, Yazdani’s CJ Blossom Park in Republic of Korea [473] also adopted the concept of folding variable shading, with retractable components to maximize daylight access.
In addition, many research institutions and laboratories have conducted relevant investigations. For instance, the Swiss Federal Institute of Technology in Zurich developed a dynamic photovoltaic (PV) sunshade system combining dynamic skin and PV cells and using a diamond matrix appearance and pneumatic control device. A complex algorithm control program was utilized to increase the light in the indoor environment, and considerable power output was achieved simultaneously [484]. Further, the Institute for Computational Design and Architecture and Institute for Architectural Structures and Structural Design at the University of Stuttgart investigated bionic-logic-based projects, such as responsive autonomous façade structures inspired by passive polyphasic plant motion and bio-inspired adaptive shading systems. They used the opening and closing principle of the plant Helminthus to design a variable shading system with a V-shaped cross-section by utilizing simulation software, which simplified the actuator and realized the opening and closing of the V-shaped shading component by a pair of pressure rods. In addition, Choi, Lee, and Jo [495] utilized variable element control of the outer layer as the entry point and developed three different response logics for a simple dynamic horizontal shading panel with the user as the center to satisfy the actual use needs of users, such as optimization of the indoor light environment, minimization of indoor energy consumption, and elimination of indoor glare.

2.1.2. Inner Variable Louver System

Compared with an outer variable shading system, an inner dynamic louver system is more controllable in terms of cost and is often integrated into a window system to form industrial production building parts. This approach is used in both renovated and new buildings. Double-layer blinds and a double-layer curtain wall with a controllable opening and closing cavity are included in this type of design. Because inner variable louver systems are mainly employed in the industrial field, they will not be detailed here.

2.2. Development of Materials with Variable Microscopic Properties

Compared with variable structures, variable material systems have the advantages of low complexity, low maintenance cost, and high operational reliability. At present, the design and development of AF based on variable materials mainly focus on phase change materials (PCMs) and programming materials.

2.2.1. PCMs

Researchers use the stability and energy storage properties of PCMs to improve the energy efficiency of buildings. Specifically, the heating and cooling loads are reduced by attenuating internal temperature fluctuations [506]. Currently, PCMs are usually combined with walls to form sandwich wall structures [517]. In some cases, the position of the PCMs in the wall section is dynamically changed to utilize the PCMs to a greater extent [528][539]. PCMs are also combined with dynamic shading devices to improve indoor light environments and adjust indoor thermal environments simultaneously.
In recent years, researchers have also utilized combinations of PCMs and transparent windows [5410]. The integration of windows with PCMs improves the utilization of solar energy, and the dual benefits of shading and energy buffering can improve indoor thermal comfort in summer and winter. Further, using PCMs in windows can affect visual performance. In 2018, the Delft University of Technology demonstrated a PCM-integrated window called Double Face, which consisted of PCM and glass layers that could regulate indoor temperature fluctuations and indoor light environments.
Often, such adjustment is not affected by the subjective opinions of the occupants, but instead, is a response of the inherent characteristics of the material under environmental stimulation. Therefore, to maximize the latent heat storage capacity of PCMs, it is next necessary to investigate how to use the material characteristic changes under the melting and solidification states to satisfy indoor environmental needs [5511].

1.2.2. Smart Materials

A smart material is a synthetic material with one or more properties that can respond independently to changes in the external environment without the need for control by mechanical or electronic components. These environmental changes include stress, temperature, humidity, pH, magnetic field, light, and carbon dioxide concentration. At present, various smart materials are utilized in architecture research and application. The materials employed include shape memory alloys, shape memory polymers, thermo-bimetals, composite bilayers, electroactive polymers, wood, and hydrogels. Based on responsiveness, they can be divided into photosensitive materials, humidity-sensitive materials, and thermal materials. They can also be distinguished by production principle (according to the physical or chemical properties of the materials combined), anisotropy (the use of one material in programming processing to achieve characteristic responses in different directions), hierarchy, and angle of the multi-level structure (scale). From a manufacturing perspective, they can be designated as programming and non-programming materials. The applications of smart materials in adaptive skin can be divided into two types: skin coverings and actuators. Two types aim is to adjust incoming solar radiation and even generate electricity in transparent enclosed spaces: traditional nanomaterial technologies—electrochromic glasses and gasochromic windows—and emerging ones—nanocrystal in-glass composites windows, electrokinetic pixel windows [5612], elastomer-deformation tunable windows, among others. Compared to other adaptive technologies, glass-level technology plays a pivotal role in existing building renovations, as it is generally easy to install.

2.3. Integration of Building Technologies with Resource Production

2.3.1. PV Integration

PVs are increasingly closely combined with construction façades, in multiple ways. One is PVs attached or applied to façades components—walls, glasses, blinds, among others—and the other is that PV replaces the traditional façade components and acts as a kind of façade component. Examples of the former include the PV Trombe wall, PV-wall, semi-transparent building-integrated PV glazing [5713], and PV panels attached to blind slats, which use microscale (or even nanoscale) technologies with inconspicuous volume. Such adaptive-skin capacities include adjusting the cavity air flow rate, flow direction, and running mechanism to control energy consumption of buildings for space heating and cooling. Another example is a PV added-double curtain wall system, which is designed to provide electricity and heat simultaneously. In summer, cavity thermal pressure ventilation can be used for natural cooling of PV modules as well as ventilation and cooling of indoor spaces. At present, curtain wall-added PV modules can satisfy the requirements of aesthetics and indoor vision, which proves the possibility of combining aesthetics, practicality, and technological innovation.
For the latter, PV as a sunshade component, usually called a PV shading device, constitutes an important part of PV integration. In recent years, considerable research on technology and methods has been conducted in Republic of Korea, China, Greece, and other countries, primarily focusing on office buildings. Zhang et al. [5814] analyzed and sorted 24 kinds of existing PV shading prototypes, including horizontal plate, vertical plate, and frame-type systems, and believed that tropical areas should fully utilize solar resources to promote the research and application of PV shading technology. Dynamic solar shading is a further optimization of the above technology, which aims to fully employ the advantages of dynamic solar shading and PV power generation. Hofer et al. [5915] verified the performance of modular dynamic PV shading with different arrangements, and the results showed that dynamic PV shading effectively improved building energy performance and residential comfort. However, methods of reducing the system cost and weighing the module spacing and occlusion influence remain topics for future research.

2.3.2. Agricultural Integration

A representation of building façade integration with agriculture is a vertical farming system.
Sustainable architecture has become a popular research topic [6016]. It has the characteristics of vertical greening and the advantages of crop production, but differs from vertical greening in terms of the design method. The crop planting and picking processes require targeted design optimization. Kosorić et al. [6117] conducted a questionnaire survey on the acceptability of building façade planting systems, with the results revealing high resident acceptance of such systems. Building skin planting has also gradually appeared in practical cases, and some service companies specialize in the design and promotion of exterior wall crop planting. In addition, different crop planting methods affect the design methods. Currently, the known planting methods include hydroponics, soil cultivation, and aeroponics [6218].

2.4. Vertical Greening Ecology Based on Environmental Benefits

Vertical greening as a long-standing means of building environment regulation can be traced to the famous hanging gardens of Babylon in the Babylonian period. It is generally installed on the roof [6319], but people have gradually noted its building façade applications. In the 1980s, Bartfelder and Kohler [6420] conducted a preliminary study on the ecological function of building façade greening. With the gradual development of technology, new technologies began to be applied to vertical greening. Blanc investigated the first hydroponic vertical greening system in 1994 [6521]. Since 2017, research has focused on the integrated use of vertical greening and PV solar energy systems in building exterior walls. The transpiration of plants can be used as a buffer layer between dynamic PV shading panels and building façades to provide cooling [6622]. It has been experimentally proven that the temperature of a PV module is slightly lower than that of a PV module without a vertical green buffer, especially in summer.

3. Performance Evaluation

3.1. Importance of Performance Evaluation

First, an AF, as a high-performance skin, is a complicated system. It generally influences multiple physical domains, including thermal properties, the amount of daylight, indoor air quality (IAQ), and energy [823][24][25][40]. These features may be correlated [4025]; therefore, evaluating the performance of multiple domains simultaneously is essential. Further, unlike traditional static façades, high-performance façades are largely dependent on nonlinear changing behaviors, including climatic conditions, operational contexts, dynamic techniques [6726], occupant behaviors [4025], and maintenance issues [3827]. Therefore, the ability of AFs to adapt to changing environmental conditions is nonlinear and cannot be fully characterized by traditional static performance indicators, such as the U-value, G-value, or T-vis [3827]. Furthermore, constantly emerging dynamic and variable control features [6726], such as interactions [6828], are increasing the intricacy of building system management. With the well-being of occupants [6929] being the ultimate goal of performance evaluation [3430], indoor environmental quality (IEQ), energy efficiency, and occupant satisfaction need to be balanced. For instance, façades control sunlight penetration to provide sufficient daylight indoors to avoid dim and glare areas, and solar gain to regulate thermal comfort and minimize energy consumption.
Second, these advanced façades are constantly adapting to the ever-changing surroundings; hence, time-variation is inherent [4025]. However, performance evaluation systems and frameworks for existing formal external façades, such as energy standards and regulations, have limited applicability to such advanced building façades [3827][7031]. Performance statements for AFs cannot be trusted without a standardized performance measurement protocol that can be consistently applied using performance criteria, although many scholars have demonstrated their advantages [3827] in enhancing energy performance and improving environmental quality. Moreover, prescriptive specifications reduce potentially fatal mistakes in most cases and represent social needs [7132], although they have the potential to hinder reformation and innovation. Currently, there are several ISO, EN, and national codes, most of which are used for project initiation [3827] and continue to be used during the operational phases. However, there is no field standard for commissioning an entire façade system [3827]. Commissioning standards for AFs that can be used throughout the building life cycle must be established to validate systems prior to operation and to adjust operation [7233] to satisfy occupant requirements.
Overall, although it is challenging to quantify and evaluate AF performance [7132], performance assessment is essential to further the development of such complex structural systems, to enable them to serve their practical role, and to increase their market share [2834]. There is currently a lack of consensus regarding evaluation criteria categories to achieve a systematic performance assessment of AFs. Section 3.2 provides an analysis of the reasons for this phenomenon.

3.2. Lack of Consensus Regarding Evaluation Criteria Categories

As AFs are multi-functional, multi-disciplinary, multi-variate, and multi-standard (Figure 4), there is a lack of agreed-upon general evaluation indicators.
The first and most prominent feature of AFs is multi-functionality. Numerous studies [7335][7436][7537] have shown that AFs have two significant functions: building energy management [7638][7739] and improving occupant comfort and health [1140][7841]. These functions are usually correlated with controlling indoor environment characteristics, such as solar heat, air flow, and noise. Researchers have attempted to superimpose the two aforementioned functions, but they are not easy to balance due to their competing requirements [6828]. For instance, when indoor occupants want to maximize daylight, additional cooling is required to avoid overheating [7942], which goes against the strategy of reducing building energy consumption. Individuals with potentially opposing expectations [8043] in a shared space must also be considered. Hence, as human needs may exhibit transient changes, a balance between multiple functions considering different environmental stimuli must be realized to achieve adaptation. The aesthetic, economic, interactive, and durability functions [6828][7537][8144] of AFs are also receiving attention, but require further in-depth research.
Figure 4. Distinctive features of AFs.

Figure 4. Distinctive features of AFs.

Second, AFs, as high-performance façades, involve the intersection of multiple disciplines, including physical, optical, and thermal simulation; materials science; chemical engineering; construction engineering; architectural design and building services engineering; and behavioral science [2524][28][6834]. Therefore, compared to traditional façades, their performance evaluation is more complex. Thus far, few studies have focused on communication across disciplines. Only Luna-Navarro et al. [6828] have proposed a classification framework consisting of an interaction diagram and associated taxonomy notation to help transfer knowledge between disciplines, thereby facilitating the design of optimal solutions to achieve satisfactory occupant–façade interactions. More in-depth research on interdisciplinary information transformation would help establish multi-faceted AF evaluation systems considering design, construction, operation, and monitoring, and thereby, increase their market share.
Third, multiple variables affect AF performance. Many of these variables, including climate change, technological progress, occupant behavior, regulations and norms, and maintenance issues [3825][4026][6727], involve uncertainty because the response of such façades is nonlinear under dynamic environmental conditions, making performance evaluation highly uncertain. For example, when occupants use building equipment, such as heating, ventilating, and air conditioning (HVAC) systems and lighting and move and open doors and windows [8245], the predicted energy consumption and actual performance deviate from the expectations. Thus, it is not appropriate to establish a general, standard, and static performance evaluation method. Further, it is not sufficient to evaluate the façade performance at a fixed point in time; instead, it is necessary to conduct life cycle assessments (LCAs) of the entire building, including during the operational phases, as well as post-occupancy measurements and monitoring [8346].
Finally, AF performance evaluation is multi-standard, because of different evaluation criteria in different disciplines as well as changing environmental variables. Ferguson et al. [8447] noted that multiple criteria must be considered when evaluating performance in different situations, as the design variables constantly change in tangible assessments. For instance, adaptation to changing climatic conditions on a daily, seasonal, or yearly basis requires different assessment methods [8346]. As another example, identifying independent standardized glare assessment indicators remains challenging when occupant conditions and local subjective responses differ [7739]. In addition, when indoor personnel undertake special tasks, thermal, visual, and other comfort conditions must be changed, and standards other than the standard comfort model may be required.

3.3. Existing Performance Evaluation

AF performance evaluations focus on aspects affecting occupant comfort and well-being. Most studies on performance have mainly focused on the optical and thermal characteristics [823][3430][8548][8649], especially those of dynamic shading façade systems. However, little is known about ventilation [8649] or acoustic performance [3430][8144][8750], even though academics agree that both functions cannot be easily ignored. The literature on ventilation often combines this aspect with indoor heat demand [651][2052] but ignores its potential to improve IAQ.
 
In terms of improving occupant comfort and well-being, researchers have emphasized that individual control, including interaction and adaptation to individual requirements [3430], is the main factor in façade evaluation. Due to the conflicting interests of operators and occupants [6726], the former, who are concerned with the cost of energy usage and maintenance, often limit the control rights of the latter, who are concerned with satisfaction and experience. Fortunately, users have become aware of the connection between interaction and their own comfort and well-being. To realize interaction between the occupants and the façade, sensors or interactive devices are needed to sense user behaviors; further, the information must be processed by the control strategy and the outer wall actuators must be executed (the details of this process are provided in Section 4). If user-centered interactions are not considered, the resulting design decisions and control strategies may be unacceptable and unsatisfactory [3430].
Interactions must also account for distinct individual requirements. Allowing personalization in AFs may result in higher occupant satisfaction and performance. Additional integrated building management systems (BMSs) can also monitor façade operation and help manage distinct individual requirements to establish a balance between façade operation execution and individual control. In order for BPSs not to hinder the market uptake of AFs [6726], they may require further investigation.
Most research on environmental performance has focused on reducing energy consumption efficiency [7638][8853][8954] as well as energy production capacity [7132][8649], which offset the net energy consumption of buildings. For instance, Jayathissa et al. [9055] evaluated the energy performance of adaptive solar façades. Each unit in the considered system rotated individually to a position that maximized energy efficiency, balancing power generation and solar penetration control while reducing energy consumption for heating, cooling, and lighting.
Very few simulations and studies have involved carbon emission capability (reduction and absorption) evaluation, although experts have affirmed this capability in interviews [8144]; this is probably because reducing energy consumption can be considered equivalent to reducing carbon emissions. However, in the case of adaptive building skins with plants, such as productive façades [9156] and green façades or living walls [9257], this fact cannot be ignored when evaluating the carbon emission capacities of buildings because plants can absorb carbon. In addition, vertical greenery systems have been shown to improve urban thermal environments to a certain extent [9358]; therefore, the larger, city-scale environmental benefits of AFs require additional research.
Many scholars have helped improve the overall performance evaluation of AF systems. For example, Kasinalis et al. [8853] developed a framework based on a genetic algorithm (GA) to analyze and quantify the energy and daylighting performance of seasonally adapted façades. Attia et al. [2834] proposed an evaluation structure that includes key performance indicators, proposing an evaluation of the necessity, performance criteria, and technical qualitative characteristics of building AF systems. Battisti et al. [7436] developed an LCA tool to assess the sustainability of the initial stages of AF technology. In addition, Yitmen et al. [9459] proposed an analytical network process model to determine the evaluation criteria for AFs in complex commercial buildings. An adaptive evaluation framework for dynamic façades was proposed in [7537], emphasizing the combination of top-down and bottom-up approaches to evaluate kinetic façades.
In general, the current performance evaluation criteria are inconsistent and lack quantification. The participation of all stakeholders involved in the design, operation, and monitoring stages is necessary to identify unanimous evaluation criteria, quantify such criteria, and ultimately promote their practical application. In addition, further accurate evaluation of both occupant comfort and well-being and environmental performance is necessary, because sometimes users are not allowed to engage with and use technologies [2834] and environmental benefits are neglected.

3.4. Building Performance Measurement Tools

There are three types of performance evaluation tools for AFs: BPSs, experiments, and personnel surveys. The first two are often used to test the façade’s ability to improve the indoor environment and realize environmental benefits, whereas personnel surveys often reflect the subjective perceptions of occupants regarding this mechanism based on social roles.
BPSs are widely utilized in building performance evaluation. Their ability to accurately quantify the advantages of buildings with AFs can facilitate the evaluation of the potential of such skins [4025][9560]. Modelling and simulations can help designers test, assess the interaction between the design and performance of, and effectively promote the development of new technologies to optimize their performance and facilitate their use in the construction market. These are in line with Bianco et al.’s [3561] emphasis on the advantages of conducting BPSs to investigate alternative design performance in the design stage. However, as mentioned previously, the simulation of AFs may be more complicated than the performance prediction of traditional static façades. One of the main reasons is that the existing performance simulation tools, such as EnergyPlus, ESP-r, ICE, and IES VE, were mostly developed during a period when adaptability was not emphasized [3225][4062][9663], and are limited in user-friendliness [4025]. Further, the integration of multiple indoor and outdoor variables to control the adaptive capacities of façades is still in the research stage [24][2564][3065]. In addition, performance evaluation by combining morphological and physiological changes has not been explored [2464]. When conducting multi-variate, multi-functional, and multi-scale evaluations, distinct degrees of simplified models may be required [9766]. Despite these limitations, it still can be combined with other tools to help support design decision-making [9867], such as ensemble multi-objective evolutionary algorithms and multi-criterion decision-making tools [7537][9867].
Approximately half of the literature has involved the examination of simulation methods alone [651], but there are often obvious gaps in field measurements. Typically, AFs do not perform as well as expected in actual applications [2834]. Therefore, in addition to simulation-based studies, experiment-based methodologies can facilitate the performance evaluation of AFs, such as by using an experimental model of a parametric camshaft structure to design an adaptive shade for a home office [9968]. Experimental methods can supplement the neglected factors that cause the apparent discrepancies between practical and simulated results to a certain extent, thereby improving the credibility of the performance value. Favoino et al. [3065] built a prototype called the ACTive, RESponsive and Solar (ACTRESS) façade and measured its thermal storage performance during winter. The thermochromic glazing performance determined based on the photochromic optical properties measured from experiments and hysteresis phenomena optimized the evaluation of daylight availability and glare [10069]. However, using either laboratory or field experiments to analyze examples of adaptive mechanisms is not sufficient [3170], possibly because of high costs and apparent complexities involved in the experimental evaluation of building envelope performance.
BPSs can be less time consuming, and different options can be considered and evaluated during the design phase to select the most appropriate option or to improve the option until it is suitable. Meanwhile, experiments are beneficial for the modelling of complicated dynamic kinematics [7537]. Few studies have involved combinations of these approaches, although scholars have clearly noted that it favors the mass production of AFs [651].
Many researchers have stated that simulations and experimental methods are sources of knowledge for scientists [2524][10171]. However, scholars are increasingly also focusing on investigating AF evaluation by individuals, including occupants and experts, to identify performance evaluation criteria. In façade projects, achieving occupant comfort, well-being, and interaction is important [2834][8346]. Attia et al. [2834] interviewed specialized façade engineers, façade contractors, and architects to help them identify trends that would facilitate the development of a performance assessment framework. Attia et al. [3430] surveyed 70 employees in an office building regarding happiness in an open-plan office with dynamic louvres. The survey results showed that most people were dissatisfied with and concerned about this project, indicating that user-centered surveys need to be incorporated into building design and that continuous follow-up needs to be performed during operation to enhance understanding among stakeholders. Direct investigations of building occupant comfort and well-being parameters may be more reliable than experiment-based studies [10272]. However, to improve the validity of surveys, it is necessary not only to select one time of the year for the survey, but also to conduct multiple surveys continuously to offset potential unidentified factors affecting the survey results.
Surveys of experts in architecture-related areas also help cross the boundaries between disciplines and utilize the accumulated experience and professional perspectives of experts to facilitate the development and application of AFs. A report on an interview survey of façade engineering experts [8144] identified parameters other than IEQ parameters, such as the feedback mechanism and system learning ability, which can help overcome the obstacles related to AF performance evaluation and delivery. After obtaining interview data, it is also necessary to use statistics to analyze the data further to identify the development trends. Experts in other fields, such as consultants, managers, and designers, must also be considered.

4. Control Systems

4.1. Factors Affecting Control

A compromise between human comfort and energy consumption produces a reasonable solution, although no study has simultaneously investigated all five main objectives: thermal comfort, sunlight, vision, glare, lighting, and energy savings [4473]. The influencing factors of control are mainly related to weather and user behavior. Researchers have recommended minimizing the uncertainties of these factors to avoid deviation from the expected performance [10374]. Optimization measures are utilized to improve the response time and ability to study the weather and to respond to the real-time variability of user behaviors by optimizing the machine learning algorithm.

4.1.1. Weather

A control parameter is defined as a sensor output that activates the response of the control strategy [10475]. Control parameters are time-varying and include building information such as location and façade orientation. Weather factors include external conditions (solar radiation, global horizontal radiation, air temperature, and wind velocity) and indoor conditions (temperature, humidity, air quality, and illumination).

4.1.2. Occupant Behavior

Scholars have noted the absence of policies to map the preferences of individual users in shared work environments [10576]. Saving energy largely depends on the degree of automation of the control system, and the system performance depends on occupant behavior or acceptance [10677][10778][10879][10980][11081][11182][11283]; therefore, additional consideration should be given to the personal preferences and needs of users when optimizing control algorithms to achieve better system performance, and thereby realize greater energy savings [4473]. Given that occupant behaviors considerably affect building energy consumption, integrating them into control logic is challenging [11283].
Occupant behaviors have not been incorporated into self-control strategies due to non-physical variables: (i) psychological parameters (personal aesthetic preferences), (ii) physiological parameters (personal preferences for temperature and lighting), and (iii) behavior and social parameters (the ability to control the behavior of occupants in a shared environment), which cannot be measured with typical sensors.
Han et al. [11283] focused on reinforcement learning, giving special attention to multi-agent systems. They reported that the current shortcomings are mainly reflected in the implementation of occupant integration (considering occupant preferences) and occupant mapping (information about presence and occupant behavior) [10576].

4.2. AF Control Methods

Specifically, occupant interaction involves a manual shutter (such as a rope that is pulled or a lever that is turned) and an electric shutter (such as a button that is pressed and held to move the shutter to the required position). Occupant interaction control methods can be employed to adjust shadows according to privacy requirements and visual preferences, which is very effective in daylight [11384]. They also result in higher satisfaction than automatic sunshades and manual shading. However, manual operation requires continuous occupant attention and cannot correspond to physical variables to achieve high thermal performance of buildings [11485]. It may also overcome the difficulties associated with the variety of occupant preferences [11586].
Automatic interaction strategies are easy to control. In addition, adjusting blinds to control glare can reduce the load of daylight and enable continuous adjustment. The added closed-loop feedback also enables automatic control strategies to work in real time. However, automatic control strategies have poor visibility and thermal comfort, do not enable long-term energy prediction, and do not allow environment customization [11687]. The occupant cannot veto [11788], resulting in poor applicability and popularization [10576]. In addition, automatic control causes blind adjustment with improper design [3689]. Further, it cannot save energy; complex lighting/shading control systems lead to dissatisfaction and capacity load [11890].
The occupant automation approaches combine the advantages of the occupant interaction and automatic interaction strategies. Specifically, occupants can control façade components according to their preferences automatically or via artificial intelligence operation (autonomous operation/intelligent sunshade control systems). However, occupants show higher satisfaction with manual or occupant-oriented control systems. If the control device is easy to use, occupants prefer to learn how to use the device, resulting in energy savings [3689].

4.3. Control Modes

The AF control strategy is equally important in the design and operation stages. It should focus on optimal annual control in the design phase and a fast control algorithm or short response time in the operation phase. In the design stage, the AF design and operating system should be evaluated by performing a BPS; however, the built-in modelling method cannot assess the dynamic thermal behavior or random user behavior over time or the interaction with the building façade [11788]. This situation usually leads designers to make conservative decisions. Moreover, the sun shading systems and architectural design layouts in shared offices are not as personalized as those in residential buildings [11788], as residents can send requests to back-end algorithms to adjust AFs in real time based on two control modes, namely, energy saving and visual comfort. Personal decision making is also considered to have significant impacts on the comfort of residents and the use of building energy [11788]. Therefore, a new algorithm was developed to enable users of shared office spaces to implement some personalization according to their visual comfort needs [11788].

4.4. Control Strategies

4.4.1. Classic Control

Classic control has the advantages of simplicity, intuitiveness, cost-effectiveness, and a quick response feedback mechanism [11991]. However, due to discontinuous adaptation, the control delay results in energy inefficiency [12092]. Classic control approaches include rule-based methods [4393] and proportional integral derivative (PID) techniques [12194]. Rule-based methods are mainly temperature control [4393], which may lead to low energy efficiency, because learning, solving incomplete data and control challenges, and handling an infinite number of possible variables are not considered in the design stage. PID techniques include proportional, integral, and differential controllers [4393]. The proportional controller compares the feedback signal with the set value and produces an output proportional to the error. The integral controller eliminates the error by changing the error value to 0 over time. The differential controller increases the system response and reduces overshooting by reducing the correction coefficient. PID controller parameter settings that are not sufficiently accurate cause difficulty and inefficiency, which have no effect in the long run [12295]. PID controllers have limited performance, require long test times, and are not suitable for nonlinear and complex systems [11991].

4.4.2. Advanced Control

Advanced control is also known as hard control. It can be used during dynamic changes and disturbances to deal with the uncertainty of unknown models [4393]. However, it has high maintenance costs, high energy consumption, and low efficiency, regardless of diversity. Advanced control methods include adaptive control, optimal control, model predictive control (MPC), feedforward/feedback control, and robust control.
MPC is cost effective [11991], is energy efficient [11991], can control multiple variables [12396], improves the steady-state response [12497], can predict upcoming control actions, enhances the transient response [11991], and reduces the computational time [12598]. MPC enables accurate and simple prediction and minimizes the primary energy costs [12699], using output and input data to determine AF behavior. MPC is the most commonly used in AF control, can solve predictive control problems to satisfy dynamic and comfort constraints [127100], and can predict the future state of the adaptive appearance. It takes the best control measures, including the objective function, prediction range, decision-making time, control variables, optimization algorithm, and feedback signal [12295]. However, MPC does not recognize the correct system model [11991].

4.4.3. Intelligent Control

Intelligent control is also called soft control. It learns from past cases to perform tasks without having to be programmed with specific rules. Such processes reduce the risk of incorrect operation, and multi-objective control procedures can be configured [10576], which reduce failures and enable comprehensive monitoring during operation. It includes the following three aspects:
  • GA: A GA is based on global and non-derivative optimization and is a wise choice when seeking a dynamic optimization objective, whether or not it contains mathematical ideas [11991]. However, this approach results in a large amount of calculation and long processing time [128101]; therefore, it is only suitable for a single target rather than for multi-target selection or dynamic calculation.
  • Artificial neural network (ANN): An ANN is a machine learning tool that learns the relationships between the inputs and outputs to predict AF performance. It includes input, output, neuron, and hidden layers [129102]. Due to its ability to manage large amounts of input data efficiently and perform fast tracking [11991][130103], it is very suitable for predictive models, nonlinear identification, and control, as well as for non-mathematical models. However, the huge data processing requirements of ANNs cause their training to be time consuming [11991] when processing highly complex data, especially for large ANNs.
  • Fuzzy logic (FL): FL is based on fuzzification, if–then rules, the inference mechanism, and defuzzification. It is similar to human reasoning and based on language models. Its features include high precision [11991] and fast tracking speed [130103], and it can reduce the tracking range through mathematical models and then use direct control algorithms [130103] to perform a rapid operation for a local fine search. However, the long-term tracking process and massive amount of calculations result in considerable time consumption that prevents a real-time response [11991]. Moreover, when dealing with more accurate models, it lacks feedback [11991] on learning strategies. It also fails in terms of high cost and medium-to-high complexity [130103].

4.4.4. Other Control

Other control methods include reinforcement learning and multi-agent control. Reinforcement learning control provides a reliable control technique for the optimization of active and passive heat accumulators in buildings, thereby achieving better performance. Although the latter can handle the control and optimization of complex systems, it requires supervision to guide and coordinate the subsystem operation.

4.4.5. Hybrid Control

Hybrid control is a combination of intelligent control and advanced/classic control. Hybrid control is stable, fast, and professional and can overcome the issue of the lack of solutions by a single façade control system by performing sufficient data training. It can combine MPC with reinforcement learning control and does not require long-time learning or accurate system simulation.

4.5. Control Implementation Methods

The control system runs based on several materials, movement modes, and mechanical components. The materials belong to three generations. The first generation includes crystalline silicon, mainly monocrystalline silicon and polysilicon, and has the advantage of higher power generation efficiency than the second generation, although its shading tolerance is poor and its efficiency decreases sharply [131104]. The second generation consists of thin films, which are not constrained by shape and can effectively resist the shadow effect and high temperatures. Due to their sufficient comprehensive performances, the first and second generations are widely used in AFs. Monocrystalline silicon and copper–indium–gallium–selenide (CIGS) thin films are the most popular. The third generation contains the emerging PV technology. Regarding movement modes, the rotation and translation modes are most widely used. Among the relevant mechanical components, the control system and actuator require more attention. For the control system, first, the signal must be input into the system through modalities such as manual input, sensors, prior internal information, manual programming, and the Internet. This input signal drives the controller action. The controller serves as the interface between the input device and the actuator and is driven by calculation. It mainly involves internal (closed-loop) control and external (open-loop) control. The internal loop control does not intervene in occupant interactions or external information input and accepts feedback loops. By contrast, external loop control can intervene in occupant interactions and does not accept feedback loops [10677]. Specifically, the controller directly provides outdoor climate information through external sensors for comparison with test points [132105]. Internal loop control is faster, more accurate, achieves higher performance, and cheaper than external loop control; however, differences in the calibration factors could cause inaccurate decisions. In addition, external loop control realizes some improvements in flexibility and energy savings in calibration. Electrical drivers and pneumatic/hydraulic actuators are the two main types. An electrical driver provides accurate control and a fast response time, although it has a complicated structure and requires very professional individuals and environment for maintenance. Pneumatic/hydraulic actuators perform better in terms of cost, safety, air source cleanliness, durability, instantaneousness of the reaction, simplicity of construction, and power; thus, pneumatic/hydraulic actuators can be generalized and standardized. However, pneumatic/hydraulic actuators have the characteristics of noise, low stability, and complex purification processes.

5. Discussion

Although AFs have gained increasing attention over the past decades, they are still not popular in markets; this is because their operation performance does not match people’s expectations. Figure 5 illustrates the predictable realization obstacles of AFs from three aspects.

Although AFs have gained increasing attention over the past decades, they are still not popular in markets; this is because their operation performance does not match people's expectations. Figure 5 illustrates the predictable realization obstacles of AFs from three aspects.

Figure 5. Barriers of AFs popularity.

Figure 5. Barriers of AFs popularity.

First, financial barriers are considered as one of the most fundamental research factors. The current consensus is that the economic factors involved in building façade projects significantly influence the final decision-making processes. For example, capital expenses and life-cycle costs may directly determine the final performance of AFs. As reflected by the AF projects mentioned in Section 2, the development of innovative technologies along with improvements in AF are likely to lead to high costs, a discrepancy between expectation and field data, and resource generation. Most projects currently use single-oriented technology, which is difficult to apply to other buildings. The lack of commercialization of such technologies is not conducive to increasing the market share of AFs. In addition, following the design step, Section 2 and Section 3 illustrate that it is more fundamental and popular to use simulation methods as they are generally and readily available compared to field-experiment investigations. However, this approach is inadequate and inaccurate, as it includes different evaluation criteria that cause a gap between theory and practice. Improvement of the resource production feature can contribute to a reduction in energy consumption. If adaptive PV shading modules can overcome the situation in which the components are blocked from each other as well as outdoor shading, such as by the shadows of urban buildings and huge trees [59], it would further decrease the net energy usage of buildings.

First, financial barriers are considered as one of the most fundamental research factors. The current consensus is that the economic factors involved in building façade projects significantly influence the final decision-making processes. For example, capital expenses and life-cycle costs may directly determine the final performance of AFs. As reflected by the AF projects mentioned in Section 2, the development of innovative technologies along with improvements in AF are likely to lead to high costs, a discrepancy between expectation and field data, and resource generation. Most projects currently use single-oriented technology, which is difficult to apply to other buildings. The lack of commercialization of such technologies is not conducive to increasing the market share of AFs. In addition, following the design step, Sections 2 and 3 illustrate that it is more fundamental and popular to use simulation methods as they are generally and readily available compared to field-experiment investigations. However, this approach is inadequate and inaccurate, as it includes different evaluation criteria that cause a gap between theory and practice. Improvement of the resource production feature can contribute to a reduction in energy consumption. If adaptive PV shading modules can overcome the situation in which the components are blocked from each other as well as outdoor shading, such as by the shadows of urban buildings and huge trees [59], it would further decrease the net energy usage of buildings.

Therefore, in the future, it will be necessary to strengthen the evaluation research on economic benefits to determine the optimal performance indicators and evaluation procedures [28] at the technical and control levels, as mentioned in the previous sections. This will promote the large-scale standardized production of AFs and increase their market share while significantly reducing their cost. Moreover, although thermal comfort is often considered one of the most important evaluation criteria, control systems generally only focus only on optics. Future control systems must be developed to simultaneously study multiple occupant-related and energy-efficiency goals.

Second, limited studies are examining the environmental benefits of AFs. The existing research mainly focuses on the internal energy usage of a single room or building, rather than conducting large-scale research (e.g., at the community and city level). Examples include façades with dynamic photovoltaics that reflect additional sunlight onto poorly lit buildings or the sky to reduce the heat island effect, or the use of vertical farming to improve the microclimate in a community. Research specifically focused on the carbon emission of AFs is also limited, probably because reduction in the energy consumption of a whole building also leads to a reduction in carbon emission. However, if building façades were planted with plants, carbon emissions could be further reduced through a reduction in the carbon footprint of food transportation, cooling, and heating and the absorption of carbon dioxide.

Therefore, future studies must expand the research to realize environmental benefits at the community and city levels, and the entire life cycles of AFs should be covered while further quantifying the evaluation criteria for both indoor and outdoor environments. A combination of artificial intelligence tools or a subset of similar machine learning approaches [76] can be used to facilitate the development of façade assessments. Evaluation criteria can be established using bionic inspiration, combined with top-down and bottom-up methods, to perform complex adaptive evaluations.

Finally, dealing with social barriers would lead to a market share improvement in AFs. That is, high social acceptability indirectly causes popularity. Improvement of aesthetics, interactivity, and accuracy/predictability can be achieved via post-occupancy assessment, interactive platforms, and developed simulation tools. Attia’s survey [67] of respondents who worked in AI Bahr Towers shows that about 50% of the participants did not hold positive attitudes towards thermal and lighting systems due to a lack of personal control and interaction with them. Therefore, enhancing the research and development of an interaction between AFs and occupants, such as linking sensors or incorporating BMSs, improves interaction ability and then social acceptability. Combined with developed performance, simulation tools [162] producing convincingly predictable data can also benefit society. For instance, when adding AFs to the façade of a completed building, it is necessary to not only to simulate their environmental benefits, but also verify the impact of the additions on the main body, such as the main body’s load-bearing structure and fireproofing and seismic proofing issues; however, there is a lack of research on this topic.

Therefore, in the future, it will be necessary to strengthen the evaluation research on economic benefits to determine the optimal performance indicators and evaluation procedures [28] at the technical and control levels, as mentioned in the previous sections. This work will promote the large-scale standardized production of AFs and increase their market share while significantly reducing their cost. Moreover, although thermal comfort is often considered one of the most important evaluation criteria, control systems generally only focus only on optics. Future control systems must be developed to simultaneously study multiple occupant-related and energy-efficiency goals.

6. Conclusions

Second, limited studies are examining the environmental benefits of AFs. The existing research mainly focuses on the internal energy usage of a single room or building, rather than conducting large-scale research (e.g., at the community and city level). Examples include façades with dynamic photovoltaics that reflect additional sunlight onto poorly lit buildings or the sky to reduce the heat island effect, or the use of vertical farming to improve the microclimate in a community. Research specifically focused on the carbon emission of AFs is also limited, probably because reduction in the energy consumption of a whole building also leads to a reduction in carbon emission. However, if building façades were planted with plants, carbon emissions could be further reduced through a reduction in the carbon footprint of food transportation, cooling, and heating and the absorption of carbon dioxide.

This study systematically presented the status quo of AFs in order to discover and identify the reasons hindering their popularity; it also suggested ways to improve the market penetration of AFs. This review contributes to stimulating AFs to achieve better energy performance in the future by removing the barriers preventing us from achieving environmental benefits; this can be achieved by significantly reducing energy consumption and greenhouse gas emissions while generally ensuring human comfort and society’s well-being. Accordingly, AFs will be widely accepted and applied in society, thereby solving the social problems that humans are facing.

Therefore, future studies must expand this research to realize environmental benefits at the community and city levels, and the entire life cycles of AFs should be covered while further quantifying the evaluation criteria for both indoor and outdoor environments. A combination of artificial intelligence tools or a subset of similar machine learning approaches [75] can be used to facilitate the development of façade assessments. Evaluation criteria can be established using bionic inspiration, combined with top-down and bottom-up methods, to perform complex adaptive evaluations.

The single-project-oriented technology of AFs is definitely an efficient way to satisfy specific user requirements, but its high prices are unaffordable for all; this fundamentally leads to its unpopularity. Few studies have focused on the retrofitting of existing building skins, and little is known about the influences such appendages would have on the main building. Additionally, people may question whether AFs can actually ensure their comfort and well-being as has been publicized; this is because the performance of many developed façades may be tested only in a virtual environment, divorced from field testing, and simulations are often based on insufficiently advanced tools and inadequate criteria. Hence, simulation tools, field experiments, and personal control need to be considered in this context.

Finally, dealing with social barriers would lead to a market share improvement in AFs. That is, high social acceptability indirectly causes popularity. Improvement of aesthetics, interactivity, and accuracy/predictability can be achieved via post-occupancy assessment, interactive platforms, and developed simulation tools. Attia’s survey [70] of respondents who worked in AI Bahr Towers shows that about 50% of the participants did not hold positive attitudes towards thermal and lighting systems due to a lack of personal control and interaction with them. Therefore, enhancing the research and development of an interaction between AFs and occupants, such as linking sensors or incorporating BMSs, improves interaction ability and then social acceptability. Combined with developed performance, simulation tools [133] producing convincingly predictable data can also benefit society. For instance, when adding AFs to the façade of a completed building, it is necessary to not only to simulate their environmental benefits, but also verify the impact of the additions on the main body, such as the main body’s load-bearing structure and fireproofing and seismic proofing issues; however, there is a lack of research on this topic.

Moreover, AF capacities have not been sufficiently explored in line with improving the indoor and outdoor environments. Specifically, the overall criteria should be quantified, and AFs’ outdoor benefits at community and city scales, such as reducing the urban island effect, should be clarified. In addition, there is a lack of research on the anti-disaster robustness of AFs; this might be because this is not the main function of building AFs. However, the establishment of consensus, normative, and well-established performance evaluation criteria are required.

References

  1. IPCC Climate Change. Synthesis Report. Contribution of Working Groups I. In II and III to the fifth Assessment Report of the Intergovernmental Panel on Climate Change 151; IPCC: Geneva, Switzerland, 2014; no. 10.1017. Hutton, S. Cologne Oval Offices. Available online: https://www.sauerbruchhutton.de/en/project/coo (accessed on 24 August 2022).
  2. Lima, F.; Nunes, M.L.; Cunha, J.; Lucena, A.F.P. Driving forces for aggregate energy consumption: A cross-country approach. Renew. Sustain. Energy Rev. 2017, 68, 1033–1050. Al Bahr Towers Office & Workplace|AHR|Architects and Building Consultants. Available online: https://www.ahr.co.uk/Al-Bahr-Towers (accessed on 24 August 2022).
  3. Huovila, P.; United Nations Environment Programme; Sustainable Consumption and Reduction Branch. Buildings and Climate Change: Status, Challenges, and Opportunities; United Nations Environment Programme, Sustainable Consumption and Production Branch: Paris, France, 2007; ISBN 978-92-807-2795-1. Park, C.J.B. Yazdani Studio. Available online: http://yazdanistudio.com/portfolio/cj-corporation-cj-blossom-park/ (accessed on 24 August 2022).
  4. Fabbri, M.; Glicker, J.; Schmatzberger, S.; Roscini, A.V. A Guidebook to European Building Policy: Key Legislation and Initiatives. Available online: https://www.bpie.eu/publication/a-guidebook-to-european-building-policy-key-legislation-and-initiatives/ (accessed on 24 July 2022).Svetozarevic, B.; Begle, M.; Jayathissa, P.; Caranovic, S.; Shepherd, R.F.; Nagy, Z.; Hischier, I.; Hofer, J.; Schlueter, A. Dynamic photovoltaic building envelopes for adaptive energy and comfort management. Nat. Energy 2019, 4, 671–682.
  5. COST Action TU1403-Adaptive Façade Network. Available online: http://tu1403.eu/?page_id=92 (accessed on 20 October 2022).Choi, S.-J.; Lee, D.-S.; Jo, J.-H. Lighting and cooling energy assessment of multi-purpose control strategies for external movable shading devices by using shaded fraction. Energy Build. 2017, 150, 328–338.
  6. Mohtashami, N.; Fuchs, N.; Fotopoulou, M.; Drosatos, P.; Streblow, R.; Osterhage, T.; Müller, D. State of the art of technologies in Adaptive Dynamic Building Envelopes (ADBEs). Energies 2022, 15, 829. Souayfane, F.; Fardoun, F.; Biwole, P.-H. Phase change materials (PCM) for cooling applications in buildings: A review. Energy Build. 2016, 129, 396–431.
  7. International Energy Agency. Technology Roadmap: Energy Efficient Building Envelopes; International Energy Agency: Paris, France, 2013.Gassar, A.A.A.; Yun, G.Y. Energy saving potential of PCMs in buildings under future climate conditions. Appl. Sci. 2017, 7, 1219.
  8. Loonen, R.C.G.M.; Trčka, M.; Cóstola, D.; Hensen, J.L.M. Climate adaptive building shells: State-of-the-art and future challenges. Renew. Sustain. Energy Rev. 2013, 25, 483–493. Bianco, L.; Vigna, I.; Serra, V. Energy assessment of a novel dynamic PCMs based solar shading: Results from an experimental campaign. Energy Build. 2017, 150, 608–624.
  9. Hosseini, S.M.; Mohammadi, M.; Rosemann, A.; Schröder, T.; Lichtenberg, J. A morphological approach for kinetic façade design process to improve visual and thermal comfort: Review. Build. Environ. 2019, 153, 186–204. Castell, A.; Martorell, I.; Medrano, M.; Pérez, G.; Cabeza, L.F. Experimental study of using PCM in brick constructive solutions for passive cooling. Energy Build. 2010, 42, 534–540.
  10. Tong, S.W.; Goh, W.P.; Huang, X.; Jiang, C. A review of transparent-reflective switchable glass technologies for building façade. Renew. Sustain. Energy Rev. 2021, 152, 111615. Bianco, L.; Komerska, A.; Cascone, Y.; Serra, V.; Zinzi, M.; Carnielo, E.; Ksionek, D. Thermal and optical characterisation of dynamic shading systems with PCMs through laboratory experimental measurements. Energy Build. 2018, 163, 92–110.
  11. Hosseini, S.M.; Mohammadi, M.; Schröder, T.; Guerra-Santin, O. Integrating Interactive kinetic façade design with colored glass to improve daylight performance based on occupants’ position. J. Build. Eng. 2020, 31, 101404. Borreguero, A.M.; Carmona, M.; Sanchez, M.L.; Valverde, J.L.; Rodriguez, J.F. Improvement of the thermal behaviour of gypsum blocks by the incorporation of microcapsules containing PCMS obtained by suspension polymerization with an optimal core/coating mass ratio. Appl. Therm. Eng. 2010, 30, 1164–1169.
  12. Knaack, U.; Klein, T.; Bilow, M.; Auer, T. Façades: Principles of Construction; Birkhäuser: Basel, Switzerland, 2014; ISBN 978-3-03821-145-7. Mukherjee, S.; Hsieh, W.L.; Smith, N.; Goulding, M.; Heikenfeld, J. Electrokinetic pixels with Biprimary inks for color displays and color-temperature-tunable smart windows. Appl. Opt. 2015, 54, 5603–5609.
  13. Başarır, B.; Altun, M. A Classification Approach for Adaptive Façades; Interdiciplinary Perspectives for Future Building Envelopes: Istanbul, Turkey, 2017. Fung, T.Y.Y.; Yang, H. Study on thermal performance of semi-transparent building-integrated photovoltaic glazings. Energy Build. 2008, 40, 341–350.
  14. Tabadkani, A.; Roetzel, A.; Li, H.X.; Tsangrassoulis, A. Design approaches and typologies of adaptive façades: A review. Automat. Construct. 2021, 121, 103450. Zhang, X.; Lau, S.-K.; Lau, S.S.Y.; Zhao, Y. Photovoltaic integrated shading devices (PVSDs): A review. Sol. Energy 2018, 170, 947–968.
  15. Xu, X.; Dessel, S.V. Evaluation of an active building envelope window-system. Build. Environ. 2008, 43, 1785–1791. Hofer, J.; Groenewolt, A.; Jayathissa, P.; Nagy, Z.; Schlueter, A. Parametric analysis and systems design of dynamic photovoltaic shading modules. Energy Sci. Eng. 2016, 4, 134–152.
  16. Panya, D.S.; Kim, T.; Choo, S. A methodology of interactive motion façades design through parametric strategies. Appl. Sci. 2020, 10, 1218. Astee, L.Y.; Kishnani, N.T. Building integrated agriculture: Utilising rooftops for sustainable food crop cultivation in Singapore. J. Green Build. 2010, 5, 105–113.
  17. Haeusler, M. Media Façades—History, Technology, Content; Avedition: Ludwigsburg, Germany, 2009; ISBN 978-3-89986-107-5. Kosorić, V.; Huang, H.; Tablada, A.; Lau, S.-K.; Tan, H.T.W. Survey on the social acceptance of the productive façade concept integrating photovoltaic and farming systems in high-rise public housing blocks in Singapore. Renew. Sustain. Energy Rev. 2019, 111, 197–214.
  18. Johnsen, K.; Winther, F.V. Dynamic façades, the smart way of meeting the energy requirements. Energy Procedia 2015, 78, 1568–1573. Kalantari, F.; Tahir, O.M.; Joni, R.A.; Fatemi, E. Opportunities and challenges in sustainability of vertical farming: A review. J. Landsc. Ecol. 2018, 11, 35–60.
  19. Romano, R. Kinetic adaptive façades. A systematic review of technological and adaptive features. In Bioclimatic Approaches in Urban and Building Design; Chiesa, G., Ed.; PoliTO Springer Series; Springer International Publishing: Cham, Switzerland, 2021; pp. 499–519. ISBN 978-3-030-59328-5. Rosasco, P.; Perini, K. Selection of (green) roof systems: A sustainability-based multi-criteria analysis. Buildings 2019, 9, 134.
  20. Jafari, M.; Alipour, A. Review of approaches, opportunities, and future directions for improving aerodynamics of tall buildings with smart façades. Sustain. Cities Soc. 2021, 72, 102979. Bartfelder, F.; Kohler, M. Experimentelle Unter- Suchungen Zur Function von Fassadenbegrünungen. Ph.D. Thesis, Technische Universität Berlin, Berlin, Germany, 1987.
  21. Stevens, S. Intelligent façades: Occupant control and satisfaction. Int. J. Sol. Energy 2001, 21, 147–160. Vertical Garden Patrick Blanc. Available online: https://www.verticalgardenpatrickblanc.com/presse/le-monde-1994 (accessed on 24 August 2022).
  22. Omar, O. Intelligent building, definitions, factors and evaluation criteria of selection. Alex. Eng. J. 2018, 57, 2903–2910. Medl, A.; Stangl, R.; Florineth, F. Vertical greening systems—A review on recent technologies and research advancement. Build. Environ. 2017, 125, 227–239.
  23. Cruz, E.; Hubert, T.; Chancoco, G.; Naim, O.; Chayaamor-Heil, N.; Cornette, R.; Menezo, C.; Badarnah, L.; Raskin, K.; Aujard, F. Design processes and multi-regulation of biomimetic building skins: A comparative analysis. Energy Build. 2021, 246, 111034. Loonen, R.C.G.M.; Trčka, M.; Cóstola, D.; Hensen, J.L.M. Climate adaptive building shells: State-of-the-art and future challenges. Renew. Sustain. Energy Rev. 2013, 25, 483–493.
  24. Kuru, A.; Oldfield, P.; Bonser, S.; Fiorito, F. Performance prediction of biomimetic adaptive building skins: Integrating multifunctionality through a novel simulation framework. Sol. Energy 2021, 224, 253–270. Kuru, A.; Oldfield, P.; Bonser, S.; Fiorito, F. Biomimetic adaptive building skins: Design and performance. In Rethinking Building Skins; Gasparri, E., Brambilla, A., Lobaccaro, G., Goia, F., Andaloro, A., Sangiorgio, A., Eds.; (Woodhead Publishing Series in Civil and Structural Engineering); Woodhead Publishing: Sawston, UK, 2022; pp. 181–200. ISBN 978-0-12-822477-9.
  25. Kuru, A.; Oldfield, P.; Bonser, S.; Fiorito, F. Biomimetic adaptive building skins: Design and performance. In Rethinking Building Skins; Gasparri, E., Brambilla, A., Lobaccaro, G., Goia, F., Andaloro, A., Sangiorgio, A., Eds.; (Woodhead Publishing Series in Civil and Structural Engineering); Woodhead Publishing: Sawston, UK, 2022; pp. 181–200. ISBN 978-0-12-822477-9. Loonen, R.C.G.M.; Favoino, F.; Hensen, J.L.M.; Overend, M. Review of current status, requirements and opportunities for building performance simulation of adaptive façades. J. Build. Perform. Simul. 2017, 10, 205–223.
  26. Carlucci, F. A review of smart and responsive building technologies and their classifications. Future Cities Environ. 2021, 7, 10. Louter, C.; Bos, F.; Belis, J. Challenges and Future Directions of Smart Sensing and Control Technology for Adaptive Façades Monitoring. In Project: Adaptive Facades Network—COST Action 1403 2018, Adaptive Facades Network Final Conference; Lucerne University of Applied Sciences and Arts: Lucerne, Switzerland, 2018.
  27. Hensen, J.; Bartak, M.; Drkal, F. Modeling and simulation of a double-skin façade system. ASHRAE Trans. 2002, 108, 1251–1259. Attia, S.; Favoino, F.; Loonen, R.; Petrovski, A.; Monge-Barrio, A. Adaptive Façades System Assessment: An Initial Review. In Proceedings of the 10th Conference on Advanced Building Skins, Munich, Germany, 3–4 November 2015; ISBN 978-3-98120538-1.
  28. Attia, S.; Bilir, S.; Safy, T.; Struck, C.; Loonen, R.; Goia, F. Current Trends and future challenges in the performance assessment of adaptive façade systems. Energy Build. 2018, 179, 165–182. Luna-Navarro, A.; Loonen, R.; Juaristi, M.; Monge-Barrio, A.; Attia, S.; Overend, M. Occupant-façade interaction: A review and classification scheme. Build. Environ. 2020, 177, 106880.
  29. Attia, S.; Bashandy, H. Evaluation of Adaptive Façades: The Case Study of AGC Headquarter in Belgium. In Proceedings of the Challenging Glass 5, Ghent University, Ghent, Belgium, 16–17 June 2016; p. 9. El-Arnaouty, H.; Azab, N.; Omar, O. Health and wellbeing re-visited; an exploratory study towards a ‘healthy & wellbeing’ university campus. Archit. Plan. J. 2020, 25, 1.
  30. Favoino, F.; Goia, F.; Perino, M.; Serra, V. Experimental assessment of the energy performance of an advanced responsive multifunctional façade module. Energy Build. 2014, 68, 647–659. Attia, S.; Garat, S.; Cools, M. Development and validation of a survey for well-being and interaction assessment by occupants in office buildings with adaptive façades. Build. Environ. 2019, 157, 268–276.
  31. Kuru, A.; Oldfield, P.; Bonser, S.; Fiorito, F. Biomimetic adaptive building skins: Energy and environmental regulation in buildings. Energy Build. 2019, 205, 109544. Attia, S. Evaluation of adaptive façades: The case study of Al Bahr Towers in the UAE. QScience Connect 2018, 2017, 6.
  32. Loonen, R.C.G.M.; Hoes, P.-J.; Hensen, J.L. Performance Prediction of Buildings with Responsive Building Elements: Challenges and Solutions; UCL: London, UK, 2014; pp. 23–24. Struck, C.; de Almeida, M.G.; Silva, S.M.; Mateus, R.; Lemarchand, P.; Petrovski, A.; Rabenseifer, R.; Wansdronk, R.; Wellershoff, F.; De Wit, J. Adaptive Façade Systems-Review of Performance Requirements, Design Approaches, Use Cases and Market Needs. In Proceedings of the 10th Energy Forum on Advanced Building Skins, Bern, Switzerland, 3–4 November 2015; Volume 1.
  33. Alice, P.; Valentina, S.; Lorenza, B.; Andrea, K. Innovative technologies for transparent building envelopes: Experimental assessment of energy and thermal comfort data to facilitate the decision-making process. In Proceedings of the International Conference on Innovations in Construction, Seville, Spain, 18–20 November 2015; p. 10. Lee, E.S.; Fernandes, L.L.; Coffey, B.; McNeil, A.; Clear, R.; Webster, T.; Bauman, F.; Dickerhoff, D.; Heinzerling, D.; Hoyt, T. A post-occupancy monitored evaluation of the dimmable lighting, automated shading, and underfloor air distribution system in the New York Times building; UC Berkeley, Center for the Built Environment: Berkeley, CA, USA, 2013; Available online: https://escholarship.org/uc/item/3km3d2sn (accessed on 1 September 2022).
  34. Attia, S.; Garat, S.; Cools, M. Development and validation of a survey for well-being and interaction assessment by occupants in office buildings with adaptive façades. Build. Environ. 2019, 157, 268–276. Attia, S.; Bilir, S.; Safy, T.; Struck, C.; Loonen, R.; Goia, F. Current Trends and future challenges in the performance assessment of adaptive façade systems. Energy Build. 2018, 179, 165–182.
  35. Bianco, L.; Cascone, Y.; Avesani, S.; Vullo, P.; Bejat, T.; Koenders, S.; Loonen, R.C.G.M.; Goia, F.; Serra, V.; Favoino, F. Towards new metrics for the characterisation of the dynamic performance of adaptive façade systems. J. Façade Des. Eng. 2018, 6, 175–196. Klein, T. Integral Façade Construction: Towards a New Product Architecture for Curtain Walls; TU Delft: Delft, The Netherlands, 2013; Volume 298.
  36. Tabadkani, A.; Roetzel, A.; Li, H.X.; Tsangrassoulis, A. A review of occupant-centric control strategies for adaptive façades. Automat. Construct. 2021, 122, 103464. Battisti, A.; Persiani, S.G.L.; Crespi, M. Review and mapping of parameters for the early stage design of adaptive building technologies through life cycle assessment tools. Energies 2019, 12, 1729.
  37. Loonen, R.; Rico-Martinez, J.M.; Favoino, F.; Marcin, B.; Ménézo, C.; La Ferla, G.; Aelenei, L. Design for Façade Adaptability—Towards a Unified and Systematic Characterization. In Proceedings of the 10th Conference on Advanced Building Skins, Bern, Switzerland, 3–4 November 2015; pp. 1284–1294. Sadegh, S.O.; Haile, S.G.; Jamshidzehi, Z. Development of two-step biomimetic design and evaluation framework for performance-oriented design of multi-functional adaptable building envelopes. J Daylighting 2022, 9, 13–27.
  38. Attia, S.; Favoino, F.; Loonen, R.; Petrovski, A.; Monge-Barrio, A. Adaptive Façades System Assessment: An Initial Review. In Proceedings of the 10th Conference on Advanced Building Skins, Munich, Germany, 3–4 November 2015; ISBN 978-3-98120538-1. Juaristi, M.; Monge-Barrio, A. Adaptive Façades in Temperate Climates. An in-Use Assessment of an Office Building. In Proceedings of the 11th Conference on Advanced Building Skins, Bern, Switzerland, 10–11 October 2016.
  39. Favoino, F. Building Performance Simulation and Characterisation of Adaptive Façades: Adaptive Façade Network; TU Delft Open: Delft, The Netherlands, 2018; ISBN 978-94-6366-111-9. Tabadkani, A.; Tsangrassoulis, A.; Roetzel, A.; Li, H.X. Innovative control approaches to assess energy implications of adaptive façades based on simulation using EnergyPlus. Sol. Energy 2020, 206, 256–268.
  40. Loonen, R.C.G.M.; Favoino, F.; Hensen, J.L.M.; Overend, M. Review of current status, requirements and opportunities for building performance simulation of adaptive façades. J. Build. Perform. Simul. 2017, 10, 205–223. Hosseini, S.M.; Mohammadi, M.; Schröder, T.; Guerra-Santin, O. Integrating Interactive kinetic façade design with colored glass to improve daylight performance based on occupants’ position. J. Build. Eng. 2020, 31, 101404.
  41. Favoino, F.; Baracani, M.; Giovannini, L.; Gennaro, G.; Goia, F. Embedding intelligence to control adaptive building envelopes. In Rethinking Building Skins; Gasparri, E., Brambilla, A., Lobaccaro, G., Goia, F., Andaloro, A., Sangiorgio, A., Eds.; Woodhead Publishing Series in Civil and Structural Engineering; Woodhead Publishing: Sawston, UK, 2022; Volume 6, pp. 155–179. ISBN 978-0-12-822477-9. Rizi, R.A.; Eltaweel, A. A user detective adaptive façade towards improving visual and thermal comfort. J. Build. Eng. 2021, 33, 101554.
  42. Juaristi, M.; Gómez-Acebo, T.; Monge-Barrio, A. Qualitative analysis of promising materials and technologies for the design and evaluation of climate adaptive opaque façades. Build. Environ. 2018, 144, 482–501. Bluyssen, P.M.; Oostra, M.A.R.; Meertins, D. Understanding the Indoor Environment: How to Assess and Improve Indoor Environmental Quality of People? In Proceedings of the CLIMA 2013: 11th REHVA World Congress & 8th International Conference on IAQVEC “Energy Efficient, Smart and Healthy Buildings”, Prague, Czech Republic, 16–19 June 2013.
  43. Alkhatib, H.; Lemarchand, P.; Norton, B.; O’Sullivan, D.T.J. Deployment and control of adaptive building façades for energy generation, thermal insulation, ventilation and daylighting: A review. Appl. Therm. Eng. 2021, 185, 116331. Lashina, T.; Chraibi, S.; Despenic, M.; Shrubsole, P.; Rosemann, A.; van Loenen, E. Sharing lighting control in an open office: Doing One’s best to avoid conflict. Build. Environ. 2019, 148, 1–10.
  44. Tabadkani, A.; Roetzel, A.; Li, H.X.; Tsangrassoulis, A. A review of automatic control strategies based on simulations for adaptive façades. Build. Environ. 2020, 175, 106801. Attia, S. Adaptive Façades Performance Assessment: Interviews with Façade Experts; SBD Laboratory: Liege, Belgium, 2019.
  45. Hutton, S. Cologne Oval Offices. Available online: https://www.sauerbruchhutton.de/en/project/coo (accessed on 24 August 2022).Peng, C.; Yan, D.; Wu, R.; Wang, C.; Zhou, X.; Jiang, Y. Quantitative description and simulation of human behavior in residential buildings. Build. Simul. 2012, 5, 85–94.
  46. Al Bahr Towers Office & Workplace|AHR|Architects and Building Consultants. Available online: https://www.ahr.co.uk/Al-Bahr-Towers (accessed on 24 August 2022).Attia, S.; Navarro, A.L.; Juaristi, M.; Monge-Barrio, A.; Gosztonyi, S.; Al-Doughmi, Z. Post-occupancy evaluation for adaptive façades. J. Façade Eng. 2018, 6, 1–9.
  47. Park, C.J.B. Yazdani Studio. Available online: http://yazdanistudio.com/portfolio/cj-corporation-cj-blossom-park/ (accessed on 24 August 2022).Ferguson, S.; Siddiqi, A.; Lewis, K.; de Weck, O.L. Flexible and reconfigurable systems: Nomenclature and review. Am. Soc. Mech. Eng. Digit. Collect. 2007, 48078, 249–263.
  48. Svetozarevic, B.; Begle, M.; Jayathissa, P.; Caranovic, S.; Shepherd, R.F.; Nagy, Z.; Hischier, I.; Hofer, J.; Schlueter, A. Dynamic photovoltaic building envelopes for adaptive energy and comfort management. Nat. Energy 2019, 4, 671–682. Aelenei, D.; Aelenei, L.; Vieira, C.P. Adaptive façade: Concept, applications, research questions. Energy Procedia 2016, 91, 269–275.
  49. Choi, S.-J.; Lee, D.-S.; Jo, J.-H. Lighting and cooling energy assessment of multi-purpose control strategies for external movable shading devices by using shaded fraction. Energy Build. 2017, 150, 328–338. Lee, C.; Lee, H.; Choi, M.; Yoon, J. Design optimization and experimental evaluation of photovoltaic double skin façade. Energy Build. 2019, 202, 109314.
  50. Souayfane, F.; Fardoun, F.; Biwole, P.-H. Phase change materials (PCM) for cooling applications in buildings: A review. Energy Build. 2016, 129, 396–431. Oral, G.K.; Yener, A.K.; Bayazit, N.T. Building envelope design with the objective to ensure thermal, visual and acoustic comfort conditions. Build. Environ. 2004, 39, 281–287.
  51. Gassar, A.A.A.; Yun, G.Y. Energy saving potential of PCMs in buildings under future climate conditions. Appl. Sci. 2017, 7, 1219. Mohtashami, N.; Fuchs, N.; Fotopoulou, M.; Drosatos, P.; Streblow, R.; Osterhage, T.; Müller, D. State of the art of technologies in Adaptive Dynamic Building Envelopes (ADBEs). Energies 2022, 15, 829.
  52. Bianco, L.; Vigna, I.; Serra, V. Energy assessment of a novel dynamic PCMs based solar shading: Results from an experimental campaign. Energy Build. 2017, 150, 608–624. Jafari, M.; Alipour, A. Review of approaches, opportunities, and future directions for improving aerodynamics of tall buildings with smart façades. Sustain. Cities Soc. 2021, 72, 102979.
  53. Castell, A.; Martorell, I.; Medrano, M.; Pérez, G.; Cabeza, L.F. Experimental study of using PCM in brick constructive solutions for passive cooling. Energy Build. 2010, 42, 534–540. Kasinalis, C.; Loonen, R.C.G.M.; Cóstola, D.; Hensen, J.L.M. Framework for assessing the performance potential of seasonally adaptable façades using multi-objective optimization. Energy Build. 2014, 79, 106–113.
  54. Bianco, L.; Komerska, A.; Cascone, Y.; Serra, V.; Zinzi, M.; Carnielo, E.; Ksionek, D. Thermal and optical characterisation of dynamic shading systems with PCMs through laboratory experimental measurements. Energy Build. 2018, 163, 92–110. Lee, D.; Cho, Y.-H.; Jo, J.-H. Assessment of control strategy of adaptive façades for heating, cooling, lighting energy conservation and glare prevention. Energy Build. 2021, 235, 110739.
  55. Borreguero, A.M.; Carmona, M.; Sanchez, M.L.; Valverde, J.L.; Rodriguez, J.F. Improvement of the thermal behaviour of gypsum blocks by the incorporation of microcapsules containing PCMS obtained by suspension polymerization with an optimal core/coating mass ratio. Appl. Therm. Eng. 2010, 30, 1164–1169. Jayathissa, P.; Schmidli, J.; Hofer, J.; Schlueter, A. Energy Performance of PV Modules as Adaptive Building Shading Systems. In Proceedings of the European Photovoltaic Solar Energy Conference (EU PVSEC), Munich, Germany, 20–24 June 2016.
  56. Mukherjee, S.; Hsieh, W.L.; Smith, N.; Goulding, M.; Heikenfeld, J. Electrokinetic pixels with Biprimary inks for color displays and color-temperature-tunable smart windows. Appl. Opt. 2015, 54, 5603–5609. Tablada, A.; Kosorić, V.; Huang, H.; Lau, S.S.Y.; Shabunko, V. Architectural quality of the productive façades integrating photovoltaic and vertical farming systems: Survey among experts in Singapore. Front. Archit. Res. 2020, 9, 301–318.
  57. Fung, T.Y.Y.; Yang, H. Study on thermal performance of semi-transparent building-integrated photovoltaic glazings. Energy Build. 2008, 40, 341–350. Perini, K.; Rosasco, P. Cost–benefit analysis for green façades and living wall systems. Build. Environ. 2013, 70, 110–121.
  58. Zhang, X.; Lau, S.-K.; Lau, S.S.Y.; Zhao, Y. Photovoltaic integrated shading devices (PVSDs): A review. Sol. Energy 2018, 170, 947–968. Daemei, A.B.; Azmoodeh, M.; Zamani, Z.; Khotbehsara, E.M. Experimental and simulation studies on the thermal behavior of vertical greenery system for temperature mitigation in urban spaces. J. Build. Eng. 2018, 20, 277–284.
  59. Hofer, J.; Groenewolt, A.; Jayathissa, P.; Nagy, Z.; Schlueter, A. Parametric analysis and systems design of dynamic photovoltaic shading modules. Energy Sci. Eng. 2016, 4, 134–152. Yitmen, I.; Al-Musaed, A.; Yücelgazi, F. ANP model for evaluating the performance of adaptive façade systems in complex commercial buildings. Eng. Constr. Archit. Manag. 2022, 29, 431–455.
  60. Astee, L.Y.; Kishnani, N.T. Building integrated agriculture: Utilising rooftops for sustainable food crop cultivation in Singapore. J. Green Build. 2010, 5, 105–113. Gassar, A.A.A.; Koo, C.; Kim, T.W.; Cha, S.H. Performance optimization studies on heating, cooling and lighting energy systems of buildings during the design stage: A review. Sustainability 2021, 13, 9815.
  61. Kosorić, V.; Huang, H.; Tablada, A.; Lau, S.-K.; Tan, H.T.W. Survey on the social acceptance of the productive façade concept integrating photovoltaic and farming systems in high-rise public housing blocks in Singapore. Renew. Sustain. Energy Rev. 2019, 111, 197–214. Bianco, L.; Cascone, Y.; Avesani, S.; Vullo, P.; Bejat, T.; Koenders, S.; Loonen, R.C.G.M.; Goia, F.; Serra, V.; Favoino, F. Towards new metrics for the characterisation of the dynamic performance of adaptive façade systems. J. Façade Des. Eng. 2018, 6, 175–196.
  62. Kalantari, F.; Tahir, O.M.; Joni, R.A.; Fatemi, E. Opportunities and challenges in sustainability of vertical farming: A review. J. Landsc. Ecol. 2018, 11, 35–60. Loonen, R.C.G.M.; Hoes, P.-J.; Hensen, J.L. Performance Prediction of Buildings with Responsive Building Elements: Challenges and Solutions; UCL: London, UK, 2014; pp. 23–24.
  63. Rosasco, P.; Perini, K. Selection of (green) roof systems: A sustainability-based multi-criteria analysis. Buildings 2019, 9, 134. Ayres, J.M.; Stamper, E. Historical Development of Building Energy Calculations. Available online: https://www.osti.gov/biblio/37088 (accessed on 17 July 2022).
  64. Bartfelder, F.; Kohler, M. Experimentelle Unter- Suchungen Zur Function von Fassadenbegrünungen. Ph.D. Thesis, Technische Universität Berlin, Berlin, Germany, 1987. Kuru, A.; Oldfield, P.; Bonser, S.; Fiorito, F. Performance prediction of biomimetic adaptive building skins: Integrating multifunctionality through a novel simulation framework. Sol. Energy 2021, 224, 253–270.
  65. Vertical Garden Patrick Blanc. Available online: https://www.verticalgardenpatrickblanc.com/presse/le-monde-1994 (accessed on 24 August 2022).Favoino, F.; Goia, F.; Perino, M.; Serra, V. Experimental assessment of the energy performance of an advanced responsive multifunctional façade module. Energy Build. 2014, 68, 647–659.
  66. Medl, A.; Stangl, R.; Florineth, F. Vertical greening systems—A review on recent technologies and research advancement. Build. Environ. 2017, 125, 227–239. Favoino, F.; Giovannini, L.; Loonen, R.C.G.M. Smart glazing in intelligent buildings: What can we simulate? In Proceedings of the Glass Performance Days Workshop (All Eyes on Glass), Tampere, Finland, 28–30 June 2017; Volume 2017, pp. 212–219.
  67. Louter, C.; Bos, F.; Belis, J. Challenges and Future Directions of Smart Sensing and Control Technology for Adaptive Façades Monitoring. In Project: Adaptive Facades Network—COST Action 1403 2018, Adaptive Facades Network Final Conference; Lucerne University of Applied Sciences and Arts: Lucerne, Switzerland, 2018. Soudian, S.; Berardi, U. Development of a performance-based design framework for multifunctional climate-responsive façades. Energy Build. 2021, 231, 110589.
  68. Luna-Navarro, A.; Loonen, R.; Juaristi, M.; Monge-Barrio, A.; Attia, S.; Overend, M. Occupant-façade interaction: A review and classification scheme. Build. Environ. 2020, 177, 106880. Sjarifudin, F.U.; Justina, L. Daylight adaptive shading using parametric camshaft mechanism for SOHO in Jakarta. EPJ Web Conf 2014, 68.
  69. El-Arnaouty, H.; Azab, N.; Omar, O. Health and wellbeing re-visited; an exploratory study towards a ‘healthy & wellbeing’ university campus. Archit. Plan. J. 2020, 25, 1. Giovannini, L.; Favoino, F.; Pellegrino, A.; Lo Verso, V.R.M.; Serra, V.; Zinzi, M. Thermochromic glazing performance: From component experimental characterisation to whole building performance evaluation. Appl. Energy 2019, 251, 113335.
  70. Attia, S. Evaluation of adaptive façades: The case study of Al Bahr Towers in the UAE. QScience Connect 2018, 2017, 6. Kuru, A.; Oldfield, P.; Bonser, S.; Fiorito, F. Biomimetic adaptive building skins: Energy and environmental regulation in buildings. Energy Build. 2019, 205, 109544.
  71. Struck, C.; de Almeida, M.G.; Silva, S.M.; Mateus, R.; Lemarchand, P.; Petrovski, A.; Rabenseifer, R.; Wansdronk, R.; Wellershoff, F.; De Wit, J. Adaptive Façade Systems-Review of Performance Requirements, Design Approaches, Use Cases and Market Needs. In Proceedings of the 10th Energy Forum on Advanced Building Skins, Bern, Switzerland, 3–4 November 2015; Volume 1. Sathyanarayanan, R.; Derome, D.; Rivard, H. The Need for an Integrated Computer-Based Tool to Support Building Envelope Design. In Proceedings of the 2nd Conference of IBPSA (eSim 2002), Montreal, Canada, 11–13 June 2022.
  72. Lee, E.S.; Fernandes, L.L.; Coffey, B.; McNeil, A.; Clear, R.; Webster, T.; Bauman, F.; Dickerhoff, D.; Heinzerling, D.; Hoyt, T. A post-occupancy monitored evaluation of the dimmable lighting, automated shading, and underfloor air distribution system in the New York Times building; UC Berkeley, Center for the Built Environment: Berkeley, CA, USA, 2013; Available online: https://escholarship.org/uc/item/3km3d2sn (accessed on 1 September 2022).Bakker, L.G.; Hoes-van Oeffelen, E.C.M.; Loonen, R.C.G.M.; Hensen, J.L.M. User satisfaction and interaction with automated dynamic façades: A pilot study. Build. Environ. 2014, 78, 44–52.
  73. Klein, T. Integral Façade Construction: Towards a New Product Architecture for Curtain Walls; TU Delft: Delft, The Netherlands, 2013; Volume 298. Tabadkani, A.; Roetzel, A.; Li, H.X.; Tsangrassoulis, A. A review of automatic control strategies based on simulations for adaptive façades. Build. Environ. 2020, 175, 106801.
  74. Battisti, A.; Persiani, S.G.L.; Crespi, M. Review and mapping of parameters for the early stage design of adaptive building technologies through life cycle assessment tools. Energies 2019, 12, 1729. Stazi, F. Thermal Inertia in Energy Efficient Building Envelopes; Butterworth-Heinemann: Oxford, UK, 2017.
  75. Sadegh, S.O.; Haile, S.G.; Jamshidzehi, Z. Development of two-step biomimetic design and evaluation framework for performance-oriented design of multi-functional adaptable building envelopes. J Daylighting 2022, 9, 13–27. Péan, T.Q.; Salom, J.; Costa-Castelló, R. Review of control strategies for improving the energy flexibility provided by heat pump systems in buildings. J. Process Control 2019, 74, 35–49.
  76. Juaristi, M.; Monge-Barrio, A. Adaptive Façades in Temperate Climates. An in-Use Assessment of an Office Building. In Proceedings of the 11th Conference on Advanced Building Skins, Bern, Switzerland, 10–11 October 2016. Plörer, D.; Hammes, S.; Hauer, M.; van Karsbergen, V.; Pfluger, R. Control strategies for daylight and artificial lighting in office buildings—A bibliometrically assisted review. Energies 2021, 14, 3852.
  77. Tabadkani, A.; Tsangrassoulis, A.; Roetzel, A.; Li, H.X. Innovative control approaches to assess energy implications of adaptive façades based on simulation using EnergyPlus. Sol. Energy 2020, 206, 256–268. Jain, S.; Garg, V. A review of open loop control strategies for shades, blinds and integrated lighting by use of real-time daylight prediction methods. Build. Environ. 2018, 135, 352–364.
  78. Rizi, R.A.; Eltaweel, A. A user detective adaptive façade towards improving visual and thermal comfort. J. Build. Eng. 2021, 33, 101554. Bellia, L.; Fragliasso, F.; Stefanizzi, E. Why are daylight-linked controls (DLCs) not so spread? A literature review. Build. Environ. 2016, 106, 301–312.
  79. Bluyssen, P.M.; Oostra, M.A.R.; Meertins, D. Understanding the Indoor Environment: How to Assess and Improve Indoor Environmental Quality of People? In Proceedings of the CLIMA 2013: 11th REHVA World Congress & 8th International Conference on IAQVEC “Energy Efficient, Smart and Healthy Buildings”, Prague, Czech Republic, 16–19 June 2013. Konstantoglou, M.; Tsangrassoulis, A. Dynamic operation of daylighting and shading systems: A literature review. Renew. Sustain. Energy Rev. 2016, 60, 268–283.
  80. Lashina, T.; Chraibi, S.; Despenic, M.; Shrubsole, P.; Rosemann, A.; van Loenen, E. Sharing lighting control in an open office: Doing One’s best to avoid conflict. Build. Environ. 2019, 148, 1–10. Fiorito, F.; Sauchelli, M.; Arroyo, D.; Pesenti, M.; Imperadori, M.; Masera, G.; Ranzi, G. Shape morphing solar shadings: A review. Renew. Sustain. Energy Rev. 2016, 55, 863–884.
  81. Attia, S. Adaptive Façades Performance Assessment: Interviews with Façade Experts; SBD Laboratory: Liege, Belgium, 2019. de Bakker, C.; Aries, M.; Kort, H.; Rosemann, A. Occupancy-based lighting control in open-plan office spaces: A state-of-the-art review. Build. Environ. 2017, 112, 308–321.
  82. Peng, C.; Yan, D.; Wu, R.; Wang, C.; Zhou, X.; Jiang, Y. Quantitative description and simulation of human behavior in residential buildings. Build. Simul. 2012, 5, 85–94. Park, J.Y.; Ouf, M.M.; Gunay, B.; Peng, Y.; O’Brien, W.; Kjærgaard, M.B.; Nagy, Z. A critical review of field implementations of occupant-centric building controls. Build. Environ. 2019, 165, 106351.
  83. Attia, S.; Navarro, A.L.; Juaristi, M.; Monge-Barrio, A.; Gosztonyi, S.; Al-Doughmi, Z. Post-occupancy evaluation for adaptive façades. J. Façade Eng. 2018, 6, 1–9. Han, M.; May, R.; Zhang, X.; Wang, X.; Pan, S.; Yan, D.; Jin, Y.; Xu, L. A review of reinforcement learning methodologies for controlling occupant comfort in buildings. Sustain. Cities Soc. 2019, 51, 101748.
  84. Ferguson, S.; Siddiqi, A.; Lewis, K.; de Weck, O.L. Flexible and reconfigurable systems: Nomenclature and review. Am. Soc. Mech. Eng. Digit. Collect. 2007, 48078, 249–263. Gunay, H.B.; O’Brien, W.; Beausoleil-Morrison, I.; Huchuk, B. On adaptive occupant-learning window blind and lighting controls. Build. Res. Inf. 2014, 42, 739–756.
  85. Aelenei, D.; Aelenei, L.; Vieira, C.P. Adaptive façade: Concept, applications, research questions. Energy Procedia 2016, 91, 269–275. Kim, J.-H.; Park, Y.-J.; Yeo, M.-S.; Kim, K.-W. An experimental study on the environmental performance of the automated blind in summer. Build. Environ. 2009, 44, 1517–1527.
  86. Lee, C.; Lee, H.; Choi, M.; Yoon, J. Design optimization and experimental evaluation of photovoltaic double skin façade. Energy Build. 2019, 202, 109314. Zhang, Y.; Barrett, P. Factors influencing occupants’ blind-control behaviour in a naturally ventilated office building. Build. Environ. 2012, 54, 137–147.
  87. Oral, G.K.; Yener, A.K.; Bayazit, N.T. Building envelope design with the objective to ensure thermal, visual and acoustic comfort conditions. Build. Environ. 2004, 39, 281–287. Yazdani-Chamzini, A.; Razani, M.; Yakhchali, S.H.; Zavadskas, E.K.; Turskis, Z. Developing a fuzzy model based on subtractive clustering for road header performance prediction. Autom. Constr. 2013, 35, 111–120.
  88. Kasinalis, C.; Loonen, R.C.G.M.; Cóstola, D.; Hensen, J.L.M. Framework for assessing the performance potential of seasonally adaptable façades using multi-objective optimization. Energy Build. 2014, 79, 106–113. Tabadkani, A.; Roetzel, A.; Li, H.X.; Tsangrassoulis, A. Simulation-based personalized real-time control of adaptive façades in shared office spaces. Autom. Constr. 2022, 138, 104246.
  89. Lee, D.; Cho, Y.-H.; Jo, J.-H. Assessment of control strategy of adaptive façades for heating, cooling, lighting energy conservation and glare prevention. Energy Build. 2021, 235, 110739. Tabadkani, A.; Roetzel, A.; Li, H.X.; Tsangrassoulis, A. A review of occupant-centric control strategies for adaptive façades. Automat. Construct. 2021, 122, 103464.
  90. Jayathissa, P.; Schmidli, J.; Hofer, J.; Schlueter, A. Energy Performance of PV Modules as Adaptive Building Shading Systems. In Proceedings of the European Photovoltaic Solar Energy Conference (EU PVSEC), Munich, Germany, 20–24 June 2016. Galasiu, A.D.; Veitch, J.A. Occupant preferences and satisfaction with the luminous environment and control systems in daylit offices: A literature review. Energy Build. 2006, 38, 728–742.
  91. Tablada, A.; Kosorić, V.; Huang, H.; Lau, S.S.Y.; Shabunko, V. Architectural quality of the productive façades integrating photovoltaic and vertical farming systems: Survey among experts in Singapore. Front. Archit. Res. 2020, 9, 301–318. Behrooz, F.; Mariun, N.; Marhaban, M.H.; Mohd Radzi, M.A.; Ramli, A.R. Review of control techniques for HVAC systems—Nonlinearity approaches based on fuzzy cognitive maps. Energies 2018, 11, 495.
  92. Perini, K.; Rosasco, P. Cost–benefit analysis for green façades and living wall systems. Build. Environ. 2013, 70, 110–121. Afram, A.; Janabi-Sharifi, F. Theory and applications of HVAC control systems—A review of model predictive control (MPC). Build. Environ. 2014, 72, 343–355.
  93. Daemei, A.B.; Azmoodeh, M.; Zamani, Z.; Khotbehsara, E.M. Experimental and simulation studies on the thermal behavior of vertical greenery system for temperature mitigation in urban spaces. J. Build. Eng. 2018, 20, 277–284. Alkhatib, H.; Lemarchand, P.; Norton, B.; O’Sullivan, D.T.J. Deployment and control of adaptive building façades for energy generation, thermal insulation, ventilation and daylighting: A review. Appl. Therm. Eng. 2021, 185, 116331.
  94. Yitmen, I.; Al-Musaed, A.; Yücelgazi, F. ANP model for evaluating the performance of adaptive façade systems in complex commercial buildings. Eng. Constr. Archit. Manag. 2022, 29, 431–455. Agarwal, T. The Working Principle of a PID Controller for Beginners. Available online: https://www.academia.edu/40787074/The_Working_Principle_of_a_PID_Controller_for_Beginners2016 (accessed on 24 July 2022).
  95. Gassar, A.A.A.; Koo, C.; Kim, T.W.; Cha, S.H. Performance optimization studies on heating, cooling and lighting energy systems of buildings during the design stage: A review. Sustainability 2021, 13, 9815. Pfeiffer, C.F.; Skeie, N.-O.; Perera, D.W.U. Control of Temperature and Energy Consumption in Buildings—A Review. Int. J. Energy Environ. 2014, 5, 471–484.
  96. Ayres, J.M.; Stamper, E. Historical Development of Building Energy Calculations. Available online: https://www.osti.gov/biblio/37088 (accessed on 17 July 2022).Karlsson, H.; Hagentoft, C.-E. Application of model based predictive control for water-based floor heating in low energy residential buildings. Build. Environ. 2011, 46, 556–569.
  97. Favoino, F.; Giovannini, L.; Loonen, R.C.G.M. Smart glazing in intelligent buildings: What can we simulate? In Proceedings of the Glass Performance Days Workshop (All Eyes on Glass), Tampere, Finland, 28–30 June 2017; Volume 2017, pp. 212–219. Xi, X.-C.; Poo, A.-N.; Chou, S.-K. Support vector regression model predictive control on a HVAC plant. Control Eng. Pract. 2007, 15, 897–908.
  98. Soudian, S.; Berardi, U. Development of a performance-based design framework for multifunctional climate-responsive façades. Energy Build. 2021, 231, 110589. Xu, M.; Li, S. Practical generalized predictive control with decentralized identification approach to HVAC systems. Energy Convers. Manag. 2007, 48, 292–299.
  99. Sjarifudin, F.U.; Justina, L. Daylight adaptive shading using parametric camshaft mechanism for SOHO in Jakarta. EPJ Web Conf 2014, 68. Humaid, A.J.; Hasan, H.M.; Raheem, F.A. Development of model predictive controller for congestion control problem. IJCCCE 2014, 14, 42–51.
  100. Giovannini, L.; Favoino, F.; Pellegrino, A.; Lo Verso, V.R.M.; Serra, V.; Zinzi, M. Thermochromic glazing performance: From component experimental characterisation to whole building performance evaluation. Appl. Energy 2019, 251, 113335. Ryzhov, A.; Ouerdane, H.; Gryazina, E.; Bischi, A.; Turitsyn, K. Model predictive control of indoor microclimate: Existing building stock comfort improvement. Energy Convers. Manag. 2019, 179, 219–228.
  101. Sathyanarayanan, R.; Derome, D.; Rivard, H. The Need for an Integrated Computer-Based Tool to Support Building Envelope Design. In Proceedings of the 2nd Conference of IBPSA (eSim 2002), Montreal, Canada, 11–13 June 2022. Gagne, J.M.; Andersen, M. Multi-objective façade optimization for daylighting design using a genetic algorithm. In Proceedings of the 4th National Conference of IBPSA-USA (SimBuild 2010), New York, NY, USA, 11–13 August 2010.
  102. Bakker, L.G.; Hoes-van Oeffelen, E.C.M.; Loonen, R.C.G.M.; Hensen, J.L.M. User satisfaction and interaction with automated dynamic façades: A pilot study. Build. Environ. 2014, 78, 44–52. Satrio, P.; Mahlia, T.M.I.; Giannetti, N.; Saito, K. Optimization of HVAC system energy consumption in a building using artificial neural network and multi-objective genetic algorithm. Sustain. Energy Technol. Assess. 2019, 35, 48–57.
  103. Stazi, F. Thermal Inertia in Energy Efficient Building Envelopes; Butterworth-Heinemann: Oxford, UK, 2017. Mao, M.; Cui, L.; Zhang, Q.; Guo, K.; Zhou, L.; Huang, H. Classification and summarization of solar photovoltaic MPPT techniques: A review based on traditional and intelligent control strategies. Energy Rep. 2020, 6, 1312–1327.
  104. Péan, T.Q.; Salom, J.; Costa-Castelló, R. Review of control strategies for improving the energy flexibility provided by heat pump systems in buildings. J. Process Control 2019, 74, 35–49. Bahr, W. A comprehensive assessment methodology of the building integrated photovoltaic blind system. Energy Build. 2014, 82, 703–708.
  105. Plörer, D.; Hammes, S.; Hauer, M.; van Karsbergen, V.; Pfluger, R. Control strategies for daylight and artificial lighting in office buildings—A bibliometrically assisted review. Energies 2021, 14, 3852. Mukherjee, S.; Birru, D.; Cavalcanti, D.; Shen, E.; Patel, M.; Wen, Y.-J.; Das, S. Closed Loop Integrated Lighting and Daylighting Control for Low Energy Buildings. In Proceedings of the ACEEE Summer Study—Energy Efficiency in Buildings, Pacific Grove, CA, USA, 15–20 August 2010; pp. 252–269.
  106. Jain, S.; Garg, V. A review of open loop control strategies for shades, blinds and integrated lighting by use of real-time daylight prediction methods. Build. Environ. 2018, 135, 352–364.
  107. Bellia, L.; Fragliasso, F.; Stefanizzi, E. Why are daylight-linked controls (DLCs) not so spread? A literature review. Build. Environ. 2016, 106, 301–312.
  108. Konstantoglou, M.; Tsangrassoulis, A. Dynamic operation of daylighting and shading systems: A literature review. Renew. Sustain. Energy Rev. 2016, 60, 268–283.
  109. Fiorito, F.; Sauchelli, M.; Arroyo, D.; Pesenti, M.; Imperadori, M.; Masera, G.; Ranzi, G. Shape morphing solar shadings: A review. Renew. Sustain. Energy Rev. 2016, 55, 863–884.
  110. de Bakker, C.; Aries, M.; Kort, H.; Rosemann, A. Occupancy-based lighting control in open-plan office spaces: A state-of-the-art review. Build. Environ. 2017, 112, 308–321.
  111. Park, J.Y.; Ouf, M.M.; Gunay, B.; Peng, Y.; O’Brien, W.; Kjærgaard, M.B.; Nagy, Z. A critical review of field implementations of occupant-centric building controls. Build. Environ. 2019, 165, 106351.
  112. Han, M.; May, R.; Zhang, X.; Wang, X.; Pan, S.; Yan, D.; Jin, Y.; Xu, L. A review of reinforcement learning methodologies for controlling occupant comfort in buildings. Sustain. Cities Soc. 2019, 51, 101748.
  113. Gunay, H.B.; O’Brien, W.; Beausoleil-Morrison, I.; Huchuk, B. On adaptive occupant-learning window blind and lighting controls. Build. Res. Inf. 2014, 42, 739–756.
  114. Kim, J.-H.; Park, Y.-J.; Yeo, M.-S.; Kim, K.-W. An experimental study on the environmental performance of the automated blind in summer. Build. Environ. 2009, 44, 1517–1527.
  115. Zhang, Y.; Barrett, P. Factors influencing occupants’ blind-control behaviour in a naturally ventilated office building. Build. Environ. 2012, 54, 137–147.
  116. Yazdani-Chamzini, A.; Razani, M.; Yakhchali, S.H.; Zavadskas, E.K.; Turskis, Z. Developing a fuzzy model based on subtractive clustering for road header performance prediction. Autom. Constr. 2013, 35, 111–120.
  117. Tabadkani, A.; Roetzel, A.; Li, H.X.; Tsangrassoulis, A. Simulation-based personalized real-time control of adaptive façades in shared office spaces. Autom. Constr. 2022, 138, 104246.
  118. Galasiu, A.D.; Veitch, J.A. Occupant preferences and satisfaction with the luminous environment and control systems in daylit offices: A literature review. Energy Build. 2006, 38, 728–742.
  119. Behrooz, F.; Mariun, N.; Marhaban, M.H.; Mohd Radzi, M.A.; Ramli, A.R. Review of control techniques for HVAC systems—Nonlinearity approaches based on fuzzy cognitive maps. Energies 2018, 11, 495.
  120. Afram, A.; Janabi-Sharifi, F. Theory and applications of HVAC control systems—A review of model predictive control (MPC). Build. Environ. 2014, 72, 343–355.
  121. Agarwal, T. The Working Principle of a PID Controller for Beginners. Available online: https://www.academia.edu/40787074/The_Working_Principle_of_a_PID_Controller_for_Beginners2016 (accessed on 24 July 2022).
  122. Pfeiffer, C.F.; Skeie, N.-O.; Perera, D.W.U. Control of Temperature and Energy Consumption in Buildings—A Review. Int. J. Energy Environ. 2014, 5, 471–484.
  123. Karlsson, H.; Hagentoft, C.-E. Application of model based predictive control for water-based floor heating in low energy residential buildings. Build. Environ. 2011, 46, 556–569.
  124. Xi, X.-C.; Poo, A.-N.; Chou, S.-K. Support vector regression model predictive control on a HVAC plant. Control Eng. Pract. 2007, 15, 897–908.
  125. Xu, M.; Li, S. Practical generalized predictive control with decentralized identification approach to HVAC systems. Energy Convers. Manag. 2007, 48, 292–299.
  126. Humaid, A.J.; Hasan, H.M.; Raheem, F.A. Development of model predictive controller for congestion control problem. IJCCCE 2014, 14, 42–51.
  127. Ryzhov, A.; Ouerdane, H.; Gryazina, E.; Bischi, A.; Turitsyn, K. Model predictive control of indoor microclimate: Existing building stock comfort improvement. Energy Convers. Manag. 2019, 179, 219–228.
  128. Gagne, J.M.; Andersen, M. Multi-objective façade optimization for daylighting design using a genetic algorithm. In Proceedings of the 4th National Conference of IBPSA-USA (SimBuild 2010), New York, NY, USA, 11–13 August 2010.
  129. Satrio, P.; Mahlia, T.M.I.; Giannetti, N.; Saito, K. Optimization of HVAC system energy consumption in a building using artificial neural network and multi-objective genetic algorithm. Sustain. Energy Technol. Assess. 2019, 35, 48–57.
  130. Mao, M.; Cui, L.; Zhang, Q.; Guo, K.; Zhou, L.; Huang, H. Classification and summarization of solar photovoltaic MPPT techniques: A review based on traditional and intelligent control strategies. Energy Rep. 2020, 6, 1312–1327.
  131. Bahr, W. A comprehensive assessment methodology of the building integrated photovoltaic blind system. Energy Build. 2014, 82, 703–708.
  132. Mukherjee, S.; Birru, D.; Cavalcanti, D.; Shen, E.; Patel, M.; Wen, Y.-J.; Das, S. Closed Loop Integrated Lighting and Daylighting Control for Low Energy Buildings. In Proceedings of the ACEEE Summer Study—Energy Efficiency in Buildings, Pacific Grove, CA, USA, 15–20 August 2010; pp. 252–269.
  133. Ascione, F.; Bianco, N.; Iovane, T.; Mastellone, M.; Mauro, G.M. The evolution of building energy retrofit via double-skin and responsive façades: A review. Sol. Energy 2021, 224, 703–717.
More
ScholarVision Creations