Three-Dimensional Visualization Technique Using Holography in a Microflow: Comparison
Please note this is a comparison between Version 2 by Conner Chen and Version 3 by Conner Chen.

Three-dimensional (3D) visualization in water is a technique that, in addition to macroscale visualization, enables micro- and nanoscale visualization via a microfabrication technique, which is particularly important in the study of biological systems. One of the applications of this technology is three-dimensional visualization technique using holography in a microflow.

 

  • micro digital holographic particle tracking velocimetry
  • microflow
  • refractive-index-matching method

1. Introduction

Methods for visualization measurements in fluids include particle image velocimetry (PIV) [1][2] and particle tracking velocimetry (PTV), which measure the flow velocity by capturing the movement of both particles and tracer particles using a high-speed camera. In addition, a method that would enable visualization of the flow around a structure in a fluid as well as the flow behind the structure is strongly demanded. Such a method would facilitate the refractive-index matching (RIM) method [3][4], which can make a structure appear transparent using a combination of a fluid and structure with the same refractive index, thereby preventing refraction and scattering from the structure in the fluid during observations of the structure’s surroundings. Several factors govern the selection of the combination of the object and the hydraulic fluid used in the RIM method. Although numerous methods have been used in combination with the RIM method, using the RIM method in combination with PIV requires a working fluid that meets several requirements. Specifically, the working fluid must (1) not corrode objects, tracer particles, or other components of the experimental system, (2) be easy to handle, exhibiting low toxicity and flammability, (3) exhibit high transmittance at fluorescence wavelengths, and (4) be inexpensive. Depending on the experimental system, it is necessary to prepare several tens to several hundred liters of hydraulic fluid, and the safety and cost aspects (including waste liquid treatment) must be considered. The combination of a sodium iodide (NaI) and acrylic is commonly used because it easily forms structures in fluids during fluid measurements [5]. PIV visualization in a sphere-packed pipe has also been conducted using a matched refractive-index method with NaI solution as the working fluid [6]. In one study, a 30% aqueous solution of potassium hydroxide and a circular pipe made of acrylic were used for PIV measurement [7]. When solution-based working fluids are used, chemical handling becomes difficult and corrosion-resistant equipment is necessary. Therefore, the RIM method using pure water (refractive index 1.33) has become important, and it is necessary to select a material for this purpose that can be used in combination with water and that exhibits a structure compatible with the RIM method.

2. Three-Dimensional Visualization Technique Using Holography in a Microflow

The role of holography-based fluid measurements in the study of fluids has already been reviewed in detail [8]. Holography-based fluid measurements applied within microflows have also been reviewed [9]. In the early stages of the development of holography fluid measurement methods, the particle position was reconstructed from an image acquired by a film plate to identify the particle position and determine the flow velocity [10]. Later, when it became clear that particle images could be captured with digital cameras [11][12][13][14][15][16][17], this technology was quickly applied in fluid measurement in the 2000s [18][19][20][21]. In holography-based fluid measurements, the configuration is classified and described in detail as in-line, off-axis, etc., according to the placement of the optical axis [22]. Historically, camera–object distances have been shortened because of the resolution constraints of camera elements and fluid measurements have been developed in microscopic systems in consideration of the in-line optical axis [23][24][25][26][27]. In particular, one group developed a microdigital holographic particle tracking velocimetry (micro-DHPTV) [28] system and developed a high-speed method [29][30] and hardware [31][32][33] to use the system to measure complex microfluid flow [34] and detect microbubbles [35]. In addition, its accuracy was verified [36] and recently various flow paths were applied [37][38]. The basic principle of hologram recording is explained here using visualization results for the inside of a tube filled with pebbles made of MEXFLON [39] as an example. Figure 1 is a schematic showing the composition of DHPTV characterized by the in-line method. Coherent laser light is used as the light source to form a hologram, which is expanded to the observation area using a beam expander. The magnified laser light passes through the test section containing tracer particles. The X–Y–Z position can be determined simultaneously by reconstructing the obtained hologram image on a computer. When a hologram was reproduced, the fringe image of the particle became the substance at the existing focal length of the particle, but came in a focus, and the image was central, and a hole opened, becoming doughnut-shaped. In addition, it grew large so that the size deviated from the focus, and, seen from the side, it was the form such as the hand drum, the fringe image of the particle in the section. Therefore, at each point of the XY plane, the greatest brightness level from all reproduction side of the point was searched. Then, the point was judged as a particle when the biggest brightness level and brightness level of the neighboring pixels of the point about each point were compared, and the greatest brightness level of the point than the brightness level of the neighboring pixels is big, and the value is bigger than the suitable threshold. The velocity vector of the fluid in the measurement volume can be obtained by detecting the moving quantity of the particle and the direction from the three-dimensional particle coordinate between two times provided by the method mentioned above. Multiple hologram images can be continuously processed, and the flow field can be visualized in three dimensions by PTV. Figure 2 shows measurements of the imprinting process by micro-DHPTV [40]. A technique called UV nano in print lithography (UV-NIL) attracts attention as a core technology of the next-generation semiconductor device process. Ultraviolet rays were irradiated, and this process rigidified resin after transforming a UV-curable resin with a mold. After the resin stiffened, high-speed pattern transcription by separating a mold was performed. However, as in the process of this UV-NIL, lack of filling or lack of hardening of the resin may happen, it was important that the flow of the photocoagulation resin during the process to imprint was measured. Micro-digital holography measurements were performed for the resin crimping process in the imprinting-process apparatus. In the optical axis direction, holographic images were acquired through the crimped glass plates. The flow became a squeezed flow. The flow phenomenon of the UV-curable resin in the imprint process by this distribution was elucidated. By substituting fluorescent particles for the tracking particles in the same macrofluids system, the velocity and temperature simultaneously were successfully measured [41]. In recent years, numerous studies have used machine learning to improve the accuracy of holographic processing.
Figure 1. Example of a setting in which DHPTV is applied to an intra-tube flow in a tube filled with MEXFLON pebbles [39].
Figure 2. DHPTV setting for squeezed flow in a UV nanoimprint process [40].

References

  1. Adrian, L.; Adrian, R.J.; Westerweel, J. Particle Image Velocimetry; Cambridge University Press: Cambridge, UK, 2011.
  2. Raffel, M.; Kähler, C.J.; Willert, C.E.; Wereley, S.T.; Scarano, F.; Kompenhans, J. Particle Image Velocimetry: A Practical Guide, 3rd ed.; Springer: Berlin/Heidelberg, Germany, 2018.
  3. Budwig, R. Refractive-Index Matching Methods for Liquid Flow Investigations. Exp. Fluids 1994, 17, 350–355.
  4. Wright, S.F.; Zadrazil, I.; Markides, C.N. A review of solid-fluid selection options for optical-based measurements in single-phase liquid, two-phase liquid-liquid and multiphase solid-liquid flows. Exp. Fluids 2017, 58, 108.
  5. Satake, S.; Aoyagi, Y.; Tsuda, T.; Unno, N.; Yuki, K. Three-dimensional flow measurement of a sphere-packed pipe by a digital hologram and refractive index-matching method. Fusion Eng. Des. 2014, 89, 1064–1067.
  6. Yuki, K.; Okurnura, M.; Hashizume, H.; Toda, S.; Morley, N.B.; Sagara, A. Flow Visualization and Heat Transfer Characteristics for Sphere-Packed Pipes. J. Thermophys. Heat Tranfer 2008, 22, 632–648.
  7. Takeuchi, J.; Satake, S.I.; Morley, N.B.; Kunugi, T.; Yokomine, T.; Abdou, M.A. Experimental study of MHD effects on turbulent flow of Flibe simulant fluid in circular pipe. Fusion Eng. Des. 2008, 83, 1082–1086.
  8. Katz, J.; Sheng, J. Applications of Holography in Fluid Mechanics and Particle Dynamics. Annu. Rev. Fluid Mech. 2010, 42, 531–555.
  9. Wereley, S.T.; Meinhart, C.D. Recent Advances in Micro-Particle Image Velocimetry. Annu. Rev. Fluid Mech. 2010, 42, 557–576.
  10. Barnhart, D.H.; Adrian, R.J.; Papen, G.C. Phase-Conjugate Holographic System for High-Resolution Particle-Image Velocimetry. Appl. Opt. 1994, 33, 7159–7170.
  11. Murata, S.; Yasuda, N. Potential of digital holography in particle measurement. Opt. Laser Technol. 2000, 32, 567–574.
  12. Xu, W.B.; Jericho, M.H.; Meinertzhagen, I.A.; Kreuzer, H.J. Digital in-line holography for biological applications. Proc. Natl. Acad. Sci. USA 2001, 98, 11301–11305.
  13. Owen, R.B.; Zozulya, A.A. In-line digital holographic sensor for monitoring and characterizing marine particulates. Opt. Eng. 2000, 39, 2187–2197.
  14. Meng, H.; Pan, G.; Pu, Y.; Woodward, S.H. Holographic particle image velocimetry: From film to digital recording. Meas. Sci. Technol. 2004, 15, 673–685.
  15. Malkiel, E.; Sheng, I.; Katz, J.; Strickler, J.R. The three-dimensional flow field generated by a feeding calanoid copepod measured using digital holography. J. Exp. Biol. 2003, 206, 3657–3666.
  16. Kebbel, V.; Adams, M.; Hartmann, H.J.; Juptner, W. Digital holography as a versatile optical diagnostic method for microgravity experiments. Meas. Sci. Technol. 1999, 10, 893–899.
  17. Schnars, U.; Juptner, W.P.O. Digital recording and numerical reconstruction of holograms. Meas. Sci. Technol. 2002, 13, R85–R101.
  18. Soria, J.; Atkinson, C. Towards 3C-3D digital holographic fluid velocity vector field measurement-tomographic digital holographic PIV (Tomo-HPIV). Meas. Sci. Technol. 2008, 19, 074002.
  19. Satake, S.I.; Kunugi, T.; Sato, K.; Ito, T. Digital holographic particle tracking velocimetry for 3-D transient flow around an obstacle in a narrow channel. Opt. Rev. 2004, 11, 162–164.
  20. Xu, W.; Jericho, M.H.; Meinertzhagen, I.A.; Kreuzer, H.J. Digital in-line holography of microspheres. Appl. Opt. 2002, 41, 5367–5375.
  21. Yamaguchi, T.; Murata, S.; Morihara, T. Three-dimensional flow measurement by digital holographic particle image velocimetry with spatio-temporal derivative method (Evaluation of the measurement accuracy by numerical simulation). JSME Int. J. Ser. B-Fluids Therm. Eng. 2006, 49, 1133–1140.
  22. Hinsch, K.D. 3-Dimensional Particle Velocimetry. Meas. Sci. Technol. 1995, 6, 742–753.
  23. Sheng, J.; Malkiel, E.; Katz, J. Using digital holographic microscopy for simultaneous measurements of 3D near wall velocity and wall shear stress in a turbulent boundary layer. Exp. Fluids 2008, 45, 1023–1035.
  24. Ooms, T.A.; Lindken, R.; Westerweel, J. Digital holographic microscopy applied to measurement of a flow in a T-shaped micromixer. Exp. Fluids 2009, 47, 941–955.
  25. Satake, S.; Kunugi, T.; Sato, K.; Ito, T.; Taniguchi, J. Three-dimensional flow tracking in a micro channel with high time resolution using micro digital-holographic particle-tracking velocimetry. Opt. Rev. 2005, 12, 442–444.
  26. Kim, S.; Lee, S.J. Measurement of 3D laminar flow inside a micro tube using micro digital holographic particle tracking velocimetry. J. Micromech. Microeng. 2007, 17, 2157–2162.
  27. Kim, S.; Lee, S.J. Effect of particle number density in in-line digital holographic particle velocimetry. Exp. Fluids 2008, 44, 623–631.
  28. Satake, S.; Kunugi, T.; Sato, K.; Ito, T.; Kanamori, H.; Taniguchi, J. Measurements of 3D flow in a micro-pipe via micro digital holographic particle tracking velocimetry. Meas. Sci. Technol. 2006, 17, 1647–1651.
  29. Satake, S.I.; Anraku, T.; Kanamori, H.; Kunugi, T.; Sato, K.; Ito, T. Study on high speed parallel algorithm using PC grid environment for visualization measurements by Digital Holographic Particle Tracking Velocimetry. Comput. Phys. Commun. 2008, 178, 1–7.
  30. Satake, S.I.; Kanamori, H.; Kunugi, T.; Sato, K.; Ito, T.; Yamamoto, K. Parallel computing of a digital hologram and particle searching for microdigital-holographic particle-tracking velocimetry. Appl. Opt. 2007, 46, 538–543.
  31. Abe, Y.; Masuda, N.; Wakabayashi, H.; Kazo, Y.; Ito, T.; Satake, S.; Kunugi, T.; Sato, K. Special purpose computer system for flow visualization using holography technology. Opt. Express 2008, 16, 7686–7692.
  32. Masuda, N.; Sugie, T.; Ito, T.; Tanaka, S.; Hamada, Y.; Satake, S.; Kunugi, T.; Sato, K. Special purpose computer system with highly parallel pipelines for flow visualization using holography technology. Comput. Phys. Commun. 2010, 181, 1986–1989.
  33. Masuda, N.; Ito, T.; Kayama, K.; Kono, H.; Satake, S.; Kunugi, T.; Sato, K. Special purpose computer for digital holographic particle tracking velocimetry. Opt. Express 2006, 14, 587–592.
  34. Satake, S.; Anraku, T.; Kanamori, H.; Kunugi, T.; Sato, K.; Ito, T. Measurements of three-dimensional flow in microchannel with complex shape by micro-digital-holographic particle-tracking-velocimetry. J. Heat Trans.-T Asme 2008, 130, 042413.
  35. Satake, S.; Yonemoto, Y.; Kikuchi, T.; Kunugi, T. Detection of microbubble position by a digital hologram. Appl. Opt. 2011, 50, 5999–6005.
  36. Ooms, T.; Koek, W.; Westerweel, J. Digital holographic particle image velocimetry: Eliminating a sign-ambiguity error and a bias error from the measured particle field displacement. Meas. Sci. Technol. 2008, 19, 074003.
  37. Yoshida, S.; Itakura, K. Compressed holographic particle tracking velocimetry for microflow measurements. Opt. Rev. 2020, 27, 441–446.
  38. Zhou, Z.; Santosh, K.S.; Mallery, K.; Jiang, W.S.; Hong, J.R. Holographic astigmatic particle tracking velocimetry (HAPTV). Meas. Sci. Technol. 2020, 31, 065202.
  39. Satake, S.; Aoyagi, Y.; Unno, N.; Yuki, K.; Seki, Y.; Enoeda, M. Three-dimensional flow measurement of a water flow in a sphere-packed pipe by digital holographic PTV. Fusion Eng. Des. 2015, 98–99, 1864–1867.
  40. Satake, S.; Taniguchi, J.; Kanai, T.; Unno, N. Three-dimensional measurements of UV-imprint process by micro-digital holographic-PTV. Microelectron Eng. 2012, 97, 51–54.
  41. Satake, S.I.; Anraku, T.; Tamoto, F.; Sato, K.; Kunugi, T. Three-dimensional simultaneous measurements of micro-fluorescent-particle position and temperature field via digital hologram. Microelectron Eng. 2011, 88, 1875–1877.
More
Video Production Service