Although the application of microsamples in metabolic phenotyping exists, it is still in its infancy, with whole blood being overwhelmingly the primary biofluid collected through the collection method of dried blood spots.
Sampling Technology | Device (Manufacturer) |
Reps (Model); Volume |
Biofluids | Description | Refs. |
---|---|---|---|---|---|
Traditional dried samples | Whatman (Cytiva; Marlborough, MA, USA) |
5 (903 Protein Saver Card); 75–80 µL |
Urine, Whole blood (WB) | Traditional paper-based carrier for collection of dried samples. | [33][34][82,83] |
PerkinElmer (PerkinElmer; Waltham, MA, USA) |
5 (226 Spot Saver Card); Up to 70 µL |
WB | Traditional paper-based carrier for collection of dried samples. | [35][84] | |
Ahlstrom-Munksjö (Ahlstrom-Munksjö; Helsinki, Finland) |
5 (BioSample Card); Up to 70 µL |
WB | Traditional paper-based carrier for collection of dried samples. | [36][85] | |
Advanced dried samples | TASSO (HemoLink; Seattle, WA, USA) |
4 (M20); 20 µL |
WB | M20 device collects four dried whole blood samples. The sample pod can be removed from the button and sent to the lab. | [25][37][38][36,77,86] |
Capitainer (Capitainer AB; Solna, Sweden) |
2 (qDBS); 10 µL 2 (B Vanadate); 10 µL |
WB | The qDBS (quantitative dried blood spot) collects two fixed-volume DBSs. A drop of blood is applied to the two microchannels within the device. After filling, the film at the capillary outlet dissolves, emptying the blood on the pre-punched Ahlstrom filter paper discs via capillary action. Successful sampling is indicated by the exit area of the device turning dark. Discs are then dried at room temperature for a minimum of 2 h. Then, the DBSs can be removed with tweezers for analysis. B Vanadate operates under the same mechanism with an additional phospholipase D inhibitor, sodium metavanadate (NaVO3), in the DBS disc, to allow for accurate phosphatidylethanol testing. | [39][40][87,88] | |
Volumetric Absorptive Microsampling (VAMS) Mitra (Neoteryx; Torrance, CA, USA) |
2 (Cartridge); 10, 20, or 30 µL 4 (Clamshell) 96 (Autorack) |
Urine, WB (incl. serum and plasma) |
A porous, absorbent white tip attached to a plastic handler. Tip consists of hydrophilic polymer and permits haematocrit-independent collection of desired fluid by wicking up an accurate volume via capillary action. Different sample volumes can be collected depending on tip size. Sample preparation can be performed manually by detaching the tip to transfer for extraction. | [41][42][89[43],90,91] | |
hemaPEN (Trajan; Melbourne, VIC, Australia) |
4; 2.74 µL |
WB | Haematocrit-independent sampling system for volumetric collection of capillary blood on pre-punched filter paper discs. Contains four Ethylenediaminetetraacetic (EDTA)-coated capillaries, which fill by touching surface of blood drop of minimally 20 µL. Subsequently, clicking device into plastic base and inverting it allows capillaries to transfer blood onto four integrated pre-punched filter paper discs. Device is available with both Whatman and Perkin Elmer discs. TGA approved. | [44][92] | |
HemaXis (DBS System SA; Gland, Switzerland) |
4 (DB10); 10 µL |
WB | DB10 utilises a conventional Whatman or Perkin Elmer card combined with 4 volumetric capillary channels. Following fingerstick lancing, a blood drop is applied to the inlet of the capillary, collecting 10 µL of blood per channel. When filling of a channel is completed, blood can be observed at the outlet of the channel. This indicates sufficient application. The device is then manually closed to allow contact between the capillary outlet and the card, taking approximately 5 s for transfer of blood. | [45][93] | |
HemaSpot (Spot On Sciences; San Francisco, CA, USA) |
Multiple (HD); 160 µL 8 (HF); 9.2 µL |
WB | The HD is a large DBS that allows for multiple technical replicates upon performing a sub-punch; HF fan-shaped device has eight identical blades in protective plastic cassette. Two–three drops of blood must be applied to the centre of the device to ensure equal distribution of blood (taking approximately one minute). Each blade holds 1/8th of the total sample volume (~9.2 µL). The device can be closed after filling and is then left to dry, facilitated by the integrated desiccant, before it is ready for extraction. | [46][47][94,95] | |
Passive separation devices | Capitainer (Capitainer AB; Solna, Sweden) |
1 (Dried plasma spot (DPS) *); 11.6 µL |
WB (separated into plasma) |
The autonomous microfluidic DPS device collects plasma samples in under 6 min. It consists of a filtration membrane, a capillary metering channel, absorbent paper, and a drainage valve to remove excess plasma. A blood drop is applied to the filtration membrane, and the filtered plasma fills the capillary metering channel before it is absorbed by the DPS paper. Excess plasma is removed by the drainage valve. | [48][74] |
Book-Type Dried Plasma Spot Cards (Q2 Solutions; Morrisville, NC, USA) |
4 (DPS *); variable (8–14 mm spots) |
WB (separated into plasma) |
Device consists of two layers that filter erythrocytes from WB to produce plasma. Blood is applied to the card in the closed-book configuration. After approximately 3 min, the sample book can be opened to collect the DPSs by removing the paper substrate. Volume of the DPS obtained depends on applied WB volume (approximately 0.303 µL plasma per 1 µL of WB). | [49][75] | |
HemaXis (DBS System SA; Gland, Switzerland) |
1 (DX *); 2µL |
WB (separated into plasma) |
The DX operates in the same way; however, it creates DPSs under the process of sedimentation once the device is closed. This is achieved through capillary pressure in a microfluidic system created with two polydimethylsiloxane sub-units. | [50][76] | |
Telimmune Plasma Separation Cards (Novilytic; West Lafayette, IN, USA) |
1 (Uno); 2.5 µL (plasma) 2 (Duo); 3.8 µL (plasma) |
WB (separated into plasma) |
Telimmune (formerly Noviplex) Uno and Duo collect dried plasma through membrane filtration. Blood is applied to the top layer of the device. Respectively, 25 µL of blood and 60 µL of blood are required for application on the devices; an indicator control spot on the top layer changes colour once this amount is reached. A separation membrane beneath the top layer retains erythrocytes through size filtration. This allows plasma to flow through. The process takes approximately 3 min, after which the top layer is peeled and discarded before drying the DPS for an additional 15 min. The DPS can then be removed using tweezers. | [51][33] | |
HemaSpot (Spot On Sciences; San Francisco, CA, USA) |
Multiple (SE); ~4 µL |
WB (separated into serum) |
SE device has a spiral-shaped design. It separates large whole blood components such as RBCs, platelets, and leukocytes from serum. Three–four blood drops applied to the centre allow the spiral-shaped membrane to separate different blood components through lateral flow. The serum components flow freely over the membrane, whereas the larger components are retained near the centre of the spiral. After sample is dried for two minutes, the cartridge is closed and is ready for analysis. Sub-punches can be made in different parts of spiral. | [52][34] | |
Whole biofluid collectors | MSW2 (Shimadzu; Kyoto, Japan) |
1 (Wing); 23 µL (WB) 5.6 µL (plasma) 14 (Windmill) |
WB (separated into plasma) |
Blood is collected at the tip of the Wing after performing a fingerstick (or similar) with a lancing device. The device is filled once blood reaches the reservoir (23 µL). A specialised centrifuge rotor is required (the Windmill), which can hold 14 Wings for centrifugation. Typically, the sample is then spun down as 2000 × G for 10 min. Following centrifugation, two plasma zones are created and can be snapped off with hands (i.e., does not require a specialised cutter) into a microtube for extraction. | [53][32] |
Touch Activated Phlebotomy (TAP) (Yourbio Health; Medford, MA, USA) |
1 (TAP); 100 µL 1 (TAP II *); 250 µL |
WB | Collects blood under vacuum pressure through microneedles, painlessly. Device sticks onto the skin (upper arm). Once button pushed, a ring of 30 small microneedles projects out of the device to micropuncture the skin. The needles immediately withdraw, creating a vacuum to induce collection of capillary blood. Blood flows through microfluidic channels into storage space, prefilled with lithium heparin anticoagulant. Subsequently, indicator window turns red when the reservoir is full (up to three minutes). Entire device can be sent to lab for collection and analysis of blood from device. | [54][55][96,97] | |
TASSO (HemoLink; Seattle, WA, USA) |
1 (TASSO+); 200–600 µL 1 (SST); 200–300 µL |
WB (incl. serum and plasma) |
Placed on upper arm. Collects WB by pressing the button, which results in a lancet puncturing the skin. Blood collected from capillaries under vacuum pressure into the sample pod (different formats). TASSO+ device collects whole blood for a variety of standard collection tubes (i.e., EDTA and lithium-heparin) and passive separation tubes (serum and plasma); SST device pod collects liquid WB, which can be spun into serum at lab. | [56][57][31,98] |