1. Photovoltaic Generator
A photovoltaic generator is a set of solar panels that convert light energy (sunlight) into electrical energy that varies depending on the influence of light and temperature, using solar cells that are connected in series and/or parallel to each other to obtain desired characteristics such as power, voltage, and current. As shown in the diagram, the equivalent circuit of a solar photovoltaic (PV) has numerous types
1. Photovoltaic Generator
A photovoltaic generator is a set of solar panels that convert light energy (sunlight) into electrical energy that varies depending on the influence of light and temperature, using solar cells that are connected in series and/or parallel to each other to obtain desired characteristics such as power, voltage, and current. As shown in the diagram, the equivalent circuit of a solar photovoltaic (PV) has numerous types
. It is determined by the number of diodes connected in series. One parallel diode, shunt resistance, series resistance, a current source, and a diode are all included in the basic version. For a single diode model, the modeling step begins with expressing the output current as shown in Equation (1).as it is in
The current of a single cell is calculated by integrating the temperature and irradiation factors:
Equation (3) presents the current in the path of the diode:
The thermal voltage of a diode is given as in Equation (4).
The diode saturation current I0 depends on the temperature of the panel. IP is the current passing through the parallel resistance of the circuit. All of these parameters may be found in Equations (5) and (6), respectively.
Then, the expression (1), becomes as it is in Equation (7).
As a result, once the number of panels in serial or parallel is determined, the whole PV system voltage and current can be stated as in Equations (8) and (9), respectively.
VPV=Ns.(a.K.Tq)ln{Np.Iph−Ipv +Np.IsNp.Is}−NsNp. Ipv.Rs
IPV=IPh.Np−I0.NP−⎡⎣⎢⎢⎢e(V+IPV.Rs.NsNp)a.VtNs−1 ⎤⎦⎥⎥⎥−V+IPV.RsNsNpRp.(NsNp)
The maximum power equals 1.5 kW that can be given by the built PV model. The model was built using the datasheet’s accessible information.
illustrates the PV module’s essential specifications. To develop a model of a 250 W solar photovoltaic module, a real PV module SUN EARTH SOLAR POWER TPB156x156-72-P 250 W was considered as a standard module.
PV system parameters per PV panel.
Parameters |
Values |
Parameters |
Values |
Parameter |
Value |
IPh |
7.9163 A |
Pn |
1500 Wh | Ki |
0.07 %/deg.C |
I0 |
1.3196 × 10 | −10 | A |
a |
0.9467 |
Isc |
7.89 A |
T |
273 + (10, 15, 25, 30) K |
Voc |
43.4 V |
Tn |
298 K |
Rs |
0.53082 Ω |
G |
(500, 750, 1000) W/m | 2 |
Rp |
159.1067 Ω |
Gn |
1000 W/m | 2 |
Vmp |
34.4 V |
Imp |
7.27 A |
K |
1.38 × 10 | −23 | J/K |
Eg |
1.2 eV |
q |
1.6 × 10 | −19 | C |
ns |
72 |
PPV |
5 kW |
VPV |
172 V |
IPV |
29.069 A |
Ns∗Np |
5*4 |
2. Wind Turbine
2. Wind Turbine
As it is known, the wind turbine system is made up of two main components. The mechanical subsystem, which describes the propeller part and the gearbox tool, which adapts the torque and speed from the two sides and converts the wind power to a mechanical power adapted to the electrical subsystem. This second subsystem is built on an electrical machine, which can be any of several different types of electrical machines
As it is known, the wind turbine system is made up of two main components. The mechanical subsystem, which describes the propeller part and the gearbox tool, which adapts the torque and speed from the two sides and converts the wind power to a mechanical power adapted to the electrical subsystem. This second subsystem is built on an electrical machine, which can be any of several different types of electrical machines
. At the end of this loop, a variety of converters and inverters are used to adapt the outputted voltage to the main load or charge.
shows this loop. In this research work, the permanent magnet machine is used to build the global wind system. In the next section, the corresponding mathematical model is given and described
.
Figure 1. Wind system control loop.
2.1. Mechanical Subsystem
Equation (10) gives the mechanical power output of the wind turbine
Wind system control loop.
2.1. Mechanical Subsystem
Equation (10) gives the mechanical power output of the wind turbine
.
Pm=Pw. Cp=12.ρ.S.V3w.Cp(λ,β)
( Cp ) represents the power coefficient of the wind turbine. It is expressed in Equation (11).
Cp(λ,β)=C1.(C2λi−C3.β−C4).e−C5λi+C6.λ
λi is given by Equation (12) as:
Equation (13) presents The Tip speed ratio.
Generally, the wind turbine specification can be analyzed by the curve, which draws the evolution of the power coefficient Cp in concordance to the angle of orientation β of propellers and the specific speed of the main shaft of the propellers noted λ.
gives this relationship. According to the law of Betz, this coefficient can reach a maximum value of 59% in theory but practically it can reach 40% for the most efficient wind turbines
.
Wind system parameters according to the propeller orientation factor.
The mechanical angular speed of the turbine is calculated using the relationship between the electrical torque and the mechanical torque, which includes the mass of the generator and the turbine as in Equation (14).
2.2. Electrical Subsystem
For the final output desired physical parameter, which is the electrical current, an electrical machine is used to generate the electrical power. Modeling this block is necessary for completing all the generator block equations
2.2. Electrical Subsystem
For the final output desired physical parameter, which is the electrical current, an electrical machine is used to generate the electrical power. Modeling this block is necessary for completing all the generator block equations
.
The use of the permanent magnet synchronous generator (PMSG) is preferable for WT technology. Due to its permanent magnets, the dynamic model of the PMSG does not depend on equations related to the rotor winding. For this, developing the dynamic model of the PMSG by using the equations of Voltage and flux. The voltage system of the equation noted (Vabcs) and magnetic flux system of the equation noted (Øabcs) can be visualized in Equations (15) and (16). All of these systems are created in a three-phase process (ABC)
The rotor reference frame can be used to characterize the PMSG’s dynamic model. As a result, the voltage system of equations in the d and q axes is:
Vqs=rs.iqs.Lq.diqs dt+ωr. Ld.ids.Øm
Vds=rs.ids+didsdt−ωr.Lq.iqs
The electromagnetic torque is given by:
Te=(32).(P2).(Øm. iqs+(Ld−Lq).iqs. ids)
The parameters of the wind system can be visualized in
.
Mechanical Parameters |
Electrical Parameters |
Parameter |
Value |
Parameter |
Value |
Parameter |
Value |
Pme |
13,500 W |
C4 |
5 |
Te |
50 N.m |
Cp |
0.48 |
C5 |
21 |
P |
4 |
Vw |
-- m/s |
C6 |
0.0068 |
Øm |
0.1688 web |
λ |
1.2 |
S |
33.36 m | 2 |
rs |
0.0918 Ω |
Ω |
300 tr/min |
ρ |
1.292 Kg/m |
ωr |
314.159 tr/min |
R |
3 m |
J |
148.5 Kg.m | 2 |
|
|
β |
0 deg |
F |
1.4 N.m.s/rad |
|
|
C1 |
0.5176 |
ωm |
31.41 rad/s |
|
|
C2 |
116 |
Tm |
45 N.m |
|
|
C3 |
0.4 |
|
|
|
|
3. Lithium Battery Pack
3. Lithium Battery Pack
The main component inside this energy loop is based on the electric energy accumulator, which is based on the lithium battery version. For assuring the needed simulation and studying correctly the comportment of this system, a mathematical battery model is required to characterize the electrical characteristics. The given mathematical model is based on a Second-Order RC Equivalent Circuit Model (ECM) to describe the external electrical performance of the battery, as shown in
The main component inside this energy loop is based on the electric energy accumulator, which is based on the lithium battery version. For assuring the needed simulation and studying correctly the comportment of this system, a mathematical battery model is required to characterize the electrical characteristics. The given mathematical model is based on a Second-Order RC Equivalent Circuit Model (ECM) to describe the external electrical performance of the battery, as shown in
. The ECM consists of an open circuit voltage source (OCV), an internal ohmic resistance R0, and two parallel RC arrays. Resistance R1 and capacity C1 are used to simulate the reactivity distribution to capture the local characteristics of the electrolyte. The charge transfer resistor R2 and the double-layer electrical capacity C2, are used to represent the interface impedance of the battery
.
Battery pack: equivalent electrical diagram.
The differential equations of the ECM are exposed in Equations (20)–(22).
Vt=Voc[SOC(t)]−V1−V2−I.R0
I is the current, R0 represents the Ohmic resistance of the storage device, V1 and V2 denote the polarization voltage over R1.C1 and R2.C2, respectively Vt is the terminal voltage, Voc represents the open-circuit voltage (OCV), which is a function of SOC.
The SOC value can be expressed as in Equation (23), where Qn is the battery rated capacity
.
SOC(t1)=SOC(t0)−∫t10I(t)dtQn
The battery rated capacity depends on the effect of the capacity fading. The remaining battery capacity available is expressed in Equation (24)
where CCF represents the Capacity correction factor and Qinit is the Initial battery capacity [Ah]. From the other side, the functioning of the battery system can be summarized by the following Equations (25) and (26).
Ech(t)=Ebat(t−1)+(EHES(t)−EL(t)).ηbat
Edis(t)=Ebat(t−1)−(EL(t)−EHES(t))
where Ech is the battery power in the charging, Edis is the battery power in the discharging, ηbat is the battery efficiency (%), EL is the load demand, and EHES is the power delivered from the energy system (W). shows the discharge characteristic example of the used battery.
shows the key specification of the considered battery.
Discharge specification of the used battery.
Battery system parameters.
Vn |
150 V |
Qn |
10 Ah |
R0 |
0.15 Ω |
4. Converters
4. Converters
Basically, numerous inverters must be used for having a DC flow from the major energy sources. A three-phase static converter based on a diode bridge rectifier (not controlled) is used to convert the alternating type (AC) electrical energy produced by the wind turbine into continuous type electrical energy (DC), connected directly by a boost converter (DC/DC) to reach the MPPT
Basically, numerous inverters must be used for having a DC flow from the major energy sources. A three-phase static converter based on a diode bridge rectifier (not controlled) is used to convert the alternating type (AC) electrical energy produced by the wind turbine into continuous type electrical energy (DC), connected directly by a boost converter (DC/DC) to reach the MPPT
. This last converter has the same objective for the photovoltaic system. On the other hand, a buck-boost converter (DC/DC) is installed to control the charge and discharge of the battery pack.
Based on these specific works, cited as
, related to the electronic converters, it is easy to express the input and output voltage of the boost converter as in Equation (27). Vint is the input voltage, Vout is the output voltage, D is duty cycling.
The buck-boost converter has two operation modes. It depends on the position of the Isolate Gate Bipolar Transistor (IGBT), which can be found inside. Supposing that these two switches have the nomination of K10 and K11. The relationship between these two parameters can be expressed in Equation (28).
As this chopper will be connected to a battery pack from one side and a DC bus line from the other side, Vbat denotes the battery voltage side and Vdc denotes the DC bus voltage side. So, the relationship between the two voltages can be expressed as in Equation (29) and the output current can be formulated as in Equation (30).
Lbat. dibatdt+rbat.ibat=Vbat−Vdc.(1−K10)