Solar Photovoltaic Systems Faults: Comparison
Please note this is a comparison between Version 1 by Ahmad Abubakar and Version 3 by Jessie Wu.

This entry pProvides an overview of common Solar PV system faults.

  • solar photovoltaics
  • artificial intelligence

1. Types of PV System Faults

In recent years, the overwhelming growth of solar photovoltaics (PV) energy generation as an alternative to conventional fossil fuel generation has encouraged the search for efficient and more reliable operation and maintenance practices, since PV systems require constant maintenance for consistent generation efficiency. One option, explored recently, is artificial intelligence (AI) to replace conventional maintenance strategies. The growing importance of AI in various real-life applications, especially in solar PV applications, cannot be over-emphasized.

Over time, PV systems experience fault occurrences that affect the system’s operating efficiency, may cause damage to the system components, and may also lead to dangerous fire threats and safety hazards. PV system faults are classified as physical, environmental or electrical faults [1][39]. Panel faults, such as PV cell internal damages, cracks in panels, bypass diodes, degradation faults, and broken panels are classified as physical faults [1][39]. Shade faults due to bird dropping, dust accumulation, cloud movement, and tree shadows are classified as environmental faults [1][39]. Faults that are classified as electrical faults include MPPT faults, open-circuit faults, ground faults, line-line faults, short-circuit faults, arc faults, and islanding operation [1][2][39,40]. This section briefly discusses the different types of faults peculiar to PV systems.

2. Shading Faults

1.1. Shading Faults

Shading occurs when objects, such as trees, neighboring buildings, and overhead power lines, cast shadows on PV modules [3][4][41,42]. Shading in PV arrays could be homogeneous, where there is a balanced reduced irradiation across the PV panels or non-homogeneous, where there is an unbalanced reduced irradiation across the panels [1][39].

3. Arc Faults

1.2. Arc Faults

A frequent high-power discharge of electricity through an air gap between conductors causes this type of fault [5][6][7][43,44,45]. The two forms of arc faults include first, the series arc faults that usually originate from solder separation, connection corrosion, cell damage, rodent damage or abrasion from numerous sources. Second, parallel arc faults that result from insulation failure in current-carrying conductors [5][6][43,44].

4. Line-Line Faults

1.3. Line-Line Faults

A line-line fault is an unintentional short-circuit between two points with differing voltage potentials [8][9][10][46,47,48]. These faults are more difficult to detect than other faults and are frequently misinterpreted as short-circuit faults in grounded PV systems, since the fault current is determined by the voltage differential between two fault spots [1][39]. The most common types of line-line faults are intra string faults, which are short-circuit faults between two locations on the same string, and cross string faults, which are short-circuit faults between two places on separate threads [1][39].

5. Ground Faults

1.4. Ground Faults

To protect users from a possible electric shock, it is common practice that the metallic parts of the PV array are grounded using earth-grounding conductors (EGC) [1][39]. The term “ground fault” refers to any unintentional connection between a current-carrying conductor and an EGC that results in a current flow to the ground [7][8][11][12][45,46,49,50].

6. Other Faults

1.5. Other Faults

This refers to any fault that cannot be categorized under any of the previously discussed faults. These types of faults include MPPT and inverter faults that mostly occur due to inverter components failure, such as IGBTs, capacitors, and converter switch failure [13][14][15][51,52,53]; bypass diode faults resulting from a massive reverse current flow during faults, which leads to short-circuits [16][17][54,55]; blocking diode faults, also as a result of a reverse current flow [1][39]; open-circuit faults caused by items falling on PV panels, physical failure of panel-panel cables or joints, and sloppy termination of cables, plugging, and unplugging connectors at junction boxes [18][56]; faulty connections damage of connecting cables or a wrong connection of panels [19][57]; battery bank failures due to abnormal charging conditions [1][39]; and blackouts caused by natural disasters, such as a storm and lightning [20][58]. Most of these mentioned faults are usually due to an after effect of the other faults [39].
References:
39. Pillai, D.S.; Rajasekar, N. A comprehensive review on protection challenges and fault diagnosis in PV systems. Renew. Sustain. Energy Rev. 2018, 91, 18–40. [CrossRef]

40. Ghosh, R.; Das, S.; Panizrahi, C.K. Classification of Different Types of Faults in a Photovoltaic System. In Proceedings of the 7th IEEE International Conference on Computation of Power, Energy, Information and Communication, Chennai, India, 28–29 March 2018; pp. 121–128.

41. Nguyen, X.H. Matlab/Simulink Based Modeling to Study Effect of Partial Shadow on Solar Photovoltaic Array. Environ. Syst. Res. 2015, 4, 20. [CrossRef]

42. Patel, H.; Agarwal, V. MATLAB-Based Modeling to Study the Effects of Partial Shading on PV Array Characteristics. IEEE Trans. Energy Convers. 2008, 23, 302–310. [CrossRef]

43. Spooner, E.; Wilmot, N. Safety issues, arcing and fusing in PV arrays. In Proceedings of the 3rd International Solar Energy Society Conference—Asia Pacific Region (ISES-AP-08) Incorporating the 46th ANZSES Conference, Sydney, Australia, 25–28 November 2008.

44. Xia, K.; He, Z.; Yuan, Y.;Wang, Y.; Xu, P. An arc fault detection system for the household photovoltaic inverter according to the DC bus currents. In Proceedings of the 2015 18th International Conference on Electrical Machines and Systems (ICEMS), Pattaya City, Thailand, 25–28 October 2015; pp. 1687–1690. [CrossRef]

45. Chen, L.; Li, S.; Wang, X. Quickest Fault Detection in Photovoltaic Systems. IEEE Trans. Smart Grid 2018, 9, 1835–1847. [CrossRef]

46. Zhao, Y.; Lehman, B.; de Palma, J.-F.; Mosesian, J.; Lyons, R. Challenges to overcurrent protection devices under line-line faults in solar photovoltaic arrays. In Proceedings of the 2011 IEEE Energy Conversion Congress and Exposition, Phoenix, AZ, USA, 17–22 September 2011. [CrossRef]

47. Zhao, Y. Fault Analysis in Solar Photovoltaic Arrays. Ph.D. Thesis, Northeastern University, Boston, MA, USA, 2010.

48. Yi, Z.; Etemadi, A.H. Line-to-Line Fault Detection for Photovoltaic Arrayst of Based on Multiresolution Signal Decomposition and Two-Stage Support Vector Machine. IEEE Trans. Ind. Electron. 2017, 64, 8546–8556. [CrossRef]

49. Appiah, A.Y.; Zhang, X.; Ayawli, B.B.K.; Kyeremeh, F. Review and Performance Evaluathese ion of Photovoltaic Array Fault Detection and Diagnosis Techniques. Int. J. Photoenergy 2019, 2019, 6953530. [CrossRef]

50. Zhao, Y.; De Palma, J.-F.; Mosentioned fsian, J.; Lyons, R.; Lehman, B. Line–Line Fault Analysis and Protection Challenges in Solar Photovoltaic Arrays. IEEE Trans. Ind. Electron. 2013, 60, 3784–3795. [CrossRef]

51. Hua, C.-C.; Kults are us, P.-K. Implementation of a Stand-Alone Photovoltaic Lighting System with MPPT, Battery Charger and High Brightness LEDs. In Proceedings of the 2005 International Conference on Power Electronics and Drives Systems, Kuala Lumpur, Malaysia, 28 November–1 December 2005; pp. 1601–1605.

52. Wang, Y.; Li, Y.; Ruan, X. High-Accurally dcy and Fast-Speed MPPT Methods for PV String Under Partially Shaded Conditions. IEEE Trans. Ind. Electron. 2016, 63, 235–245. [CrossRef]

53. Chan, F.; Calleja, H. Reliability: A New Approach in Design of Inverters for PV Systems. In Proceedings of the 2006 IEEE International Power Electronics Congress, Puebla, to Mexico, 16–18 October 2006; pp. 1–6. [CrossRef]

54. Mellit, A.; Tina, G.M.; Kalogirou, S.A. Fault detection after efand diagnosis methods for photovoltaic systems: A review. Renew. Sustain. Energy Rev. 2018, 91, 1–17. [CrossRef]

55. Davarifar, M.; Rabhi, A.; El Hajjaji, A. Comprect of the othensive Modulation and Classification of Faults and Analysis Their Effect in DC Side of Photovoltaic System. Energy Power Eng. 2013, 5, 230–236. [CrossRef]

56. Akram, M.N.; Lotfifard, S. Modeling and Health Monitoring of DC Sider f of Photovoltaic Array. IEEE Trans. Sustain. Energy 2015, 6, 1245–1253. [CrossRef]

57. Schimpf, F.; Norum, L.E. Recognition of electric arcing in the DC-wiring of photovoltaic systems. In Proceedings of the Intelec 2009—31st International Telecommunications Energy Conference, Incheon, Korea, 18–22 October 2009; pp. 1–6. [CrossRef]

58. Omer, A. Renewable energy resources for electsricity generation in Sudan. Renew. Sustain. [1]Energy Rev. 2007, 11, 1481–1497. [CrossRef]
Video Production Service