Eleven distinct categories of PEC reactors are identified in this review; though different, there are some key defining parameters of any PEC reactor, i.e., the irradiation of the photoelectrode, which can be either back-face or front-face (). For back-face irradiation, a conductive transparent supporting substrate is required (e.g., FTO), while with front-face irradiation, any suitable conducting supporting material can be used. Pablos et al.
[46][42] demonstrated improved rates of
E. coli inactivation when using a front-face configuration compared to a back-face one, using a TiO
2 (P25) particulate film on ITO with a Ni mesh counter electrode. The improvement was attributed to the mechanism of direct photoinactivation of
E. coli by UV irradiation, ROS generated by PECs and the impact of hole mobility when using back-face irradiation. However, for methanol oxidation, back-face irradiation showed slightly improved kinetics, which was attributed to the porosity of the TiO
2 particulate film that enables the diffusion of methanol, a known hole scavenger, from the aqueous phase into the porous film and thus the limitations of hole mobility were less profound. Therefore, the optimal orientation of the photoanode may be dependent on the required application and characteristics of the water. For example, back-face irradiation should be used where the water has high turbidity or low UV transmission.
Another key parameter of any PEC reactor is the irradiation source, such as UV fluorescent lamps
[46,47][42][43]; alternatively, more environmentally friendly and efficient UV LEDs have been used but are more expensive
[48,49][44][45]. The advantage of using artificial irradiation is the ability to operate at any time with a uniform and consent photon flux. To avoid the associated costs, solar energy can be used as a free energy source and presents a truly clean technology. To date, there have been very few real solar experiments reported using PECs, although xenon lamps that can simulate the solar spectrum have been used
[50][46]. The problem associated with real solar irradiation is the daily variation in solar irradiance, leading to variation in treatment times and a lack of efficient or suitable reactor designs. Moreover, for a PEC system to be a truly “
clean” method of water treatment, the input energy (irradiation and external electrical bias) should be derived from a renewable source, e.g., solar or wind.
The remaining design parameters are geometrically and operationally based; most of the PEC reactors in this review used an n-type photoanode (commonly titania) and an inert counter electrode. The different reactor categories are discussed in the following segments.
4.1. Experimental Reactors for Photoelectrode Testing
For the initial examination of photoelectrodes, small-scale experimental reactors are required to adequately control the reaction parameters, e.g., irradiation profile, temperature, mass transport, aeration, etc. A common experimental reactor is a two or three electrode system using a stirred tank reactor, commonly with a water jacket to regulate temperature
[50,51,52,53][46][47][48][49]. A typical set-up is displayed in a. It can utilise both front-face and back-face electrodes, enables air or gas sparging, mixing can be achieved with magnetic stirring and temperature control via the use of the water jacket and samples can be taken from the reactor.
Figure 8. (a) Quartz water-jacketed PEC; (b) a back-face irradiated reactor.
Pablos et al.
[54][50] used a reactor akin to the one in a and reported that when comparing different photoanode materials, the magnitude of the photocurrent does not correlate to the rate of disinfection, i.e., titania nanotubes with a photocurrent of 175 μA gave a 5-log reduction of
E. coli in 120 min but nitrogen-doped nanotubes with a lower photocurrent of 165 μA achieved 5-log reduction of
E. coli in only 60 min. This can be attributed to the complex cycling of electrons between the defect states and the mid-gap states introduced by N-doping, and the resulting reductive reactions which can take place on the photoanode, and it was suggested that some of the electrons are transferred to molecular oxygen to form superoxide radical anions
[55][51].
For back-face irradiated electrodes, an alternative design can be used such as the stirred tank reactor used by McMurray et al.
[56][52]. It enables the maximum irradiation to be absorbed by the photocatalyst film, and a stainless steel propeller was used for both mixing and as the counter electrode by using a carbon bush to make an electrical contact. Alternatively, a more traditional photoelectrochemical cell, as shown in b, can be used for electrochemical analyses.
The experimental reactors described can also be used for photoelectrochemical measurements with a potentiostat; for example, linear sweep and cyclic voltammetry, amperometry, voltammetry and transient photocurrent response. Additionally, electrochemical impedance spectroscopy (EIS) can be used to examine charge transfer and to determine the flat band potential through Mott–Schottky analysis
[57][53]. When combined with a monochromatic source, photoelectrochemical measurements can be used to determine the spectral photocurrent response and the incident photon conversion efficiency (IPCE)
[58][54].
4.2. Annular Cylinder Reactor
The use of fluorescent UV lamps has resulted in designs in which the lamp is placed in the centre of the reactor, leading to annular cylindrical reactor designs and can be originated either horizontally
[46,59][42][55] or vertically
[47][43]. This configuration ensures that photons emitted in all directions are utilised by the rector. The design of Pablos et al.
[46][42] () aimed to scale up a particulate film of TiO
2 (P25) on ITO to be used as the photoanode for the treatment of wastewaters.
Figure 9. (
a) Schematic representation of the experimental set-up, (
b) PEC reactor cross-sectional view. (Adapted with permission from
[46][42]: Pablos, C.; Marugán, J.; Adán, C.; Osuna, M.; van Grieken, R. Performance of TiO
2 photoanodes toward oxidation of methanol and
E. coli inactivation in water in a scaled-up photoelectrocatalytic reactor.
Electrochim. Acta 2017,
258, 599–606, doi:10.1016/j.electacta.2017.11.103. Copyright (2017), Elsevier (Amsterdam, The Netherlands)).
To ensure that the counter electrode (nickel mesh) is close to the photoanode without short-circuiting, 5 mm Teflon® spacers were used. Methanol oxidation shows no changes with different applied potentials but, for disinfection, the optimal potential was +1.4 V for a 3-log reduction of E. coli after 140 min to treat 1 L.
The inclusion of air/oxygen sparging directly into the reactor can take the form of an annular bubble column reactor, for example, is the design used by Kim et al.
[47][43]. This has two purposes, firstly, the supply of oxygen for reductive pathways and, secondly, to introduce turbulence, enabling improved mass transport
[60][56].
Figure 10. Schematic representation of the PEC annular bubble column reactor. (Reproduced with permission from
[47][43]: Kim, J.Y.U.; Bessegato, G.G.; de Souza, B.C.; da Silva, J.J.; Zanoni, M.V.B. Efficient treatment of swimming pool water by photoelectrocatalytic ozonation: Inactivation of
Candida parapsilosis and mineralization of Benzophenone-3 and urea.
Chem. Eng. J. 2019, 378, 122094; DOI:10.1016/j.cej.2019.122094. Copyright (2019), Elsevier (Amsterdam, The Netherlands)).
As titania nanotubes have been shown to improve photocurrent and degradation rates compared to a particulate film
[54][50], it is therefore of interest to incorporate anodised TiO
2 nanotubes into a reactor, as with the reactor of Kim et al. Their system used a titanium cylinder with titania nanotubes, a DSA
® (De Nora) cathode and a UVB lamp (36 W) to examine the degradation of benzophenone-3 (a sunscreen compound), urea and the fungal species
Candida parapsilosis with the aim of treating swimming pool water. The system was purged with O
2 and/or with O
3, as ozone alone can be used for water treatment
[61][57], its incorporation with PECs showed further improved degradation rates. With increasing applied bias of +1.0, +1.5 and +2.0 V, the degradation only improved slightly each time. After a 20 min treatment, the order of effectiveness for TOC reduction was PEC + O
3 > PEC > O
3. The standard figure of merit was used to examine the economics as a function of electric usage, as proposed by Bolton et al.
[62][58] for first-order kinetic reactions with the units kW h m
−3 order
−1. The PEC results (58.2 kW h m
−3 order
−1) show the highest cost compared to PEC + O
3 (21.4) and O
3 (9.8), though the increased rate of PEC + O
3 is more than the increased cost compared to O
3. Further cost reduction can be achieved by using higher efficiency lighting, e.g., LEDs, or the use of solar irradiation.
The cylindrical design of Montenegro-Ayo et al.
[63][59] used titanium discs which were anodised to produce a titania nanotube array, the counter electrode was unmodified titanium discs and the irradiation source was a 14 W UVC lamp (275 nm). A schematic of the reactor is presented in . The reactor was tested for the degradation of acetaminophen (10 mg L
−1) in 0.02 M Na
2SO
4. Different applied cell biases were examined (0, 4, 8, 16, 32, 64 V) and, at +8.0 V, there was a 95% reduction after 5 h when operated under irradiation compared to 3% for only electrolytic and 72% for photocatalytic degradation (open circuit). Increasing the applied bias >+8.0 V did not offer a significant improvement in the rate but did significantly increased the energy requirement.
Figure 11. Schematic representation of the experimental set-up using anodised titanium photoanode. (Adapted with permission from
[63][59]: Montenegro-Ayo, R.; Morales-Gomero, J.C.; Alarcon, H.; Cotillas, S.; Westerhoff, P.; Garcia-Segura, S. Scaling up Photoelectrocatalytic Reactors: A TiO
2 Nanotube-Coated Disc Compound Reactor Effectively Degrades Acetaminophen.
Water 2019,
11, 2522, doi:10.3390/w11122522. Copyright (2019), MDPI (Basel, Switzerland)).
4.3. Compound Parabolic Collector
For real solar applications, cylindrical reactors can be combined with a solar concentrator to increase the irradiance directed into the reactor. Specifically, the compound parabolic collector (CPC) has the advantage of irradiating the tube with both direct and diffused irradiation regardless of the time of day without the need for solar tracking, enabling the full circumference of the reactor to be irradiated with a one-sun equivalent
[64][60]. The two-compartment cell design of Fernandez-Ibañez et al.
[65][61] used a CPC reactor, as displayed in .
Figure 12. Schematic of the two-compartment reactor with a CPC.
The inner compartment contained 0.2 M H
2SO
4 (pH = 0.4) and the high concertation of protons can be reduced to form hydrogen at the cathode; in this case, a glass substrate coated with SnO
2 and Pt using a solution of H
2PtCl
6. The working compartment used 0.02 M H
2SO
4 (pH = 1.4) to degrade 4-chlorophenol and pyrimethanil with a dip-coated particulate film of TiO
2 onto titanium in which the film thickness was 100 nm and the average particle size was 27 nm. The photooxidation of 4-chlorophenol at +1.4 V (RHE) resulted in a normalised reduction rate of 7.3 mg min
−1 m
−2, this is 69 times the rate for a TiO
2 slurry reactor (0.106 mg min
−1 m
−2), and increasing to +1.8 V (RHE) resulted in a smaller reduction of 3.8 mg min
−1 m
−2, concurring with others that there is optimal bias when using PECs
[66][62]. For pyrimethanil degradation at +1.5 V (RHE), the rate was 6.21 mg min
−1 m
−2, 59 times higher than the value found for TiO
2 slurries.
The design of McMichael et al.
[67][63] () used a single-compartment reactor with a titania nanotube array produced by anodisation of a titanium mesh to be used as the photoanode, a carbon felt counter electrode placed in the centre of the reactor and an applied cell potential of +1.0 V.
Figure 13. PEC reactor configuration with CPC. (Reproduced with permission from
[67][63]: McMichael, S.; Waso, M.; Reyneke, B.; Khan, W.; Byrne, J.A.; Fernandez-Ibanez, P. Electrochemically assisted photocatalysis for the disinfection of rainwater under solar irradiation.
Appl. Catal. B 2021,
281, 119485, doi:10.1016/j.apcatb.2020.119485. Copyright (2021), Elsevier Elsevier (Amsterdam, The Netherlands)).
The reactor was angled to maximise the solar irradiance at solar noon and purged with air from the bottom of the reactor. The reactor was tested under real solar irradiance with an average UV intensity of 1.12 mW cm−2, for the inactivation of environmental strains of E. coli and P. aeruginosa using rainwater as the electrolyte which was autoclaved before use and had a conductivity of 70 μS cm−2. No additional electrolytes were added to the solution. The PEC reactor achieved a 5.5-log reduction for E. coli and a 5.8-log reduction of P. aeruginosa. The PEC reactor improved the performance of solar inactivation compared to a solar-only reactor of the same geometry that was tested in tandem. The inactivation of the microorganisms was also examined by molecular analyses using ethidium monoazide bromide, a nucleic acid-binding dye, as a pre-treatment before running a quantitative real-time polymerase chain reaction to examine if the membrane of the cell had been damaged. The PEC reactor showed a higher reduction in gene copies, demonstrating that the PEC process is more effective for the inactivation of microorganisms compared to solar only.
4.4. Flatplate or Sandwich Reactor
These reactors are categorised as having flat electrodes which are commonly parallel to each other, like the reactor design of Mousset et al.
[68][64] shown in . Their reactors used FTO glass coated with TiO
2 nanoparticles and a porous carbon felt counter electrode with a 6 W UVA (365 nm peak) lamp. The base of the reactor was 3D printed and used recirculating water, and the first reactor design sparged O
2 into a separate tank and the second and more effective reactor sparged O
2 directly into the reactor, and the improvement was attributed to the direct absorption of O
2 onto the carbon cathode, which can then be reduced, demonstrated by the increase in H
2O
2 generation. Other studies have shown improvement with increased airflow rate
[69][65]. The results showed a 73.2 ± 1.2% reduction of phenol after 8 h when applying a fixed current density of 1.25 mA cm
−2 (PEC) compared to 44% for photocatalysis alone. When using a fixed current (galvanostatic), the potential must not rise significantly to the point at which damage can be caused to the photoelectrode
[70][66]. The system was also examined using Fe(III)-hydroxy for the Fenton process and although it increased the rate of phenol degradation, for practical applications, it will require the removal of the iron catalyst, which defects the point using immobilised photocatalysts.
Figure 14. Reactor (1) air bubbled in a separate tank,
Reactor (2) air bubbled directly into reactor. (Reproduced with permission from
[68][64]: Mousset, E.; Huang Weiqi, V.; Foong Yang Kai, B.; Koh, J.S.; Tng, J.W.; Wang, Z.; Lefebvre, O. A new 3D-printed photoelectrocatalytic reactor combining the benefits of a transparent electrode and the Fenton reaction for advanced wastewater treatment.
J. Mater. Chem. A 2017,
5, 24951–24964, doi:10.1039/c7ta08182k. Copyright (2017), Royal Society of Chemistry Publishing (Cambridge, UK)).
Bai et al.
[71][67] examined the use of a thin cell reactor (a), in which the thickness of the solution (distance from the surface of the electrode to the window) was 0.2 mm, minimising the UV absorption by the solution and maximising the surface to volume ratio. Compared to a conventional PEC reactor (c), the thin cell reactor achieved a 54.8% reduction compared to 14.6% with an initial concentration of 120 mg L
−1 of tetracycline after 1 h, with a +2.0 V bias and a flow rate of 10 mL min
−1. The design also enabled irradiation from both sides of the photoelectrode (b), which doubled the performance. Overall, the thin cell reactor confirms the need for a high surface to volume ratio, sufficient mass transfer, efficient use of photons and the need for an efficient photoanode.
Figure 15. Schematic diagram of the TNA-based thin-layer PEC reactor (
a,
b) and the conventional PEC reactor (
c). (Reproduced with permission from
[71][67]: Bai, J.; Liu, Y.; Li, J.; Zhou, B.; Zheng, Q.; Cai, W. A novel thin-layer photoelectrocatalytic (PEC) reactor with double-faced titania nanotube arrays electrode for effective degradation of tetracycline.
Appl. Catal. B 2010,
98, 154–160, doi:10.1016/j.apcatb.2010.05.024. Copyright (2010), Elsevier (Amsterdam, The Netherlands)).
The flatplate reactor of Byrne et al.
[72][68] used a TiO
2 photoanode prepared by electrophoretic deposition of P25 on ITO-coated soda lime glass (1.0 ± 0.2 mg cm
−2) and a Pt-coated Ti mesh counter, positioned parallel to each other, with a re-circulating solution at a rate of 60 mL min
−1 and two 18 W UVA lamps (peak 370 nm) as the irradiation source. The reactor was tested for the degradation of formic acid (3.18 mM) with KNO
3 as the supporting electrolyte (0.5 M pH = 3) and an applied potential of +1.0 V (SCE). The incident photon to current efficiency was 2.2% and the apparent quantum yield for the degradation of formic acid was 7%. Interestingly, the O
2 sparged solution resulted in lower photocurrent and reduction values compared to air sparged solutions.
4.5. Channel/Microchannel Reactor
The previously stated thin cell reactor had a high surface to volume ratio, as does the channel/microchannel reactor; however, the following category has a more distinct and defined style compared to the previous flat thin cell reactor. To increase the residence time and improve the mass transfer in the reactor, channels can be incorporated into the design ().
Figure 16. Schematic of a channel reactor using titanium nanotubes annealed in 2% hydrogen. (Reproduced with permission from
[70][66]: Carlson, K.; Elliott, C.; Walker, S.; Misra, M.; Mohanty, S. An effective, point-of-usewater disinfection device using immobilized black TiO
2 nanotubes as an electrocatalyst.
J. Electrochem. Soc. 2016,
163, H395–H401, doi:10.1149/2.0651606jes. Copyright (2016), IOP Publishing (Bristol, UK)).
The design of Carlson et al.
[70][66] () used a titania nanotube photoelectrode annealed in 2% hydrogen in a channel reactor and a flow rate of 50 mL min
−1 which leads to a contact time of 25 s. To increase the rate of disinfection, 50 mg L
−1 NaCl was added to natural lake water which increased the conductivity and promoted the production of chorine radicals which was beneficial to the disinfection process
[73][69]. The system was operated at +6.0 V as increasing to +7.0 V caused the nanotubes to delaminate from the surface, and no bacteria were detected with and without 100 mWcm
−2 of solar irradiation with an initial
E. coli concentration of 165 CFU 100 mL
−1. The potential used exceeds the forward voltage of TiO
2, hence the irradiation only increasing the current density by 34 μAcm
−2/7.7% compared to the dark current (404 μAcm
−2); thus, the authors dubbed the reactor as an electrocatalytic reactor rather than a PEC reactor.
Alternatively, a microchannel reactor () can be used, in which the channel is 1–1000 μm; this has the advantages of having a significantly larger surface to volume ratio (10–30 cm
2cm
−3) compared to other PEC reactors (0.7–5 cm
2cm
−3 [46][42]) and fine flow control using inlet and outlet branches to ensure a uniform flow and, therefore, achieving a near consent residence time
[74][70], there is also improved mass transport and direct photon absorption at the surface of the photoelectrode with minimal photon absorption by the solution
[49][45]. However, these reactors can be difficult to scale up, resulting in non-uniform residence times and, for real water sources, particulates of a set size would have to be filtered to prevent blockages within the microchannels
[75][71]. The design of Wang et al.
[49][45] used a thin film of monoclinic BiVO
4 (n-type) on ITO as the photoelectrode with an ITO counter electrode for the degradation of methylene blue, and 0.1 M NaCl as the electrolyte and a flow rate of 75 μL min
−1 were used, and the seemingly small flow rate is due to reactor size (1 cm × 1 cm). As an example, scaling up to 20 cm × 20 cm would results in a flow rate of 1.8 L h
−1. The flow rate of any flat microchannel reactor can be easily calculated using Equation (6), where Q is the flow rate, S is the surface area, H is the height of the reactor and t is the residence time.
Figure 17. (
a) Cross-sectional view of the reaction chamber, (
b) photo of the PEC microreactor. (Adapted with permission from
[49][45]: Wang, N.; Zhang, X.; Chen, B.; Song, W.; Chan, N.Y.; Chan, H.L.W. Microfluidic photoelectrocatalytic reactors for water purification with an integrated visible-light source.
Lab Chip 2012,
12, 3983–3990, doi:10.1039/c2lc40428a. Copyright (2012), Royal Society of Chemistry Publishing (Cambridge, UK)).
A blue LED (peak 402 nm) was used as a compact light source, with high energy efficiency, low heating and which delivers direct and uniform irradiation, and the intensity can be controlled by the applied voltage to the LED, so at 10 V, the power density was 80 mWcm−2, and increasing to 11 V resulted in 140 mWcm−2 but also results in heating (>30 °C). The microchannel reactor was tested with a range of different cell voltages (−2.2 V to +2.2 V), and the optimal anodic potential was +1.5 V, with higher potentials resulting in lower degradation rates. The negative biases exhibited higher performance, i.e., when used as a photocathode (N.B. no other reports on BiVO4 as a (photo)cathode could be found), and this was attributed to the higher electrical current. O2 reduction to form ROS is the dominating pathway for degradation, and chloride ions scavenge the •OH, leading to weaker chloride radicals, and using the BiVO4 to reduce oxygen is more effective than ITO.
Microchannel reactors have also been used for the inactivation of
E. coli [48,76][44][72]. The design of Liu et al.
[48][44], with a channel depth of 250 μm, examined both a particulate and titania nanotubes as the photoanode, with a Pt mesh auxiliary electrode and a UV LED array (8 mWcm
−2, 365 nm) and using a 0.1 M NaNO
3 electrolyte. The potential was fixed at +0.7 V (Ag/AgCl) as this was the point of photocurrent saturation for the nanotube photoelectrode. The nanotube array reached the detection limit with a resistance time of 97 s compared to 311 s with the particulate film (based on the method reported, this would be a ~6-log reduction. N.B. a reduction in microorganisms should ideally be reported in log
10 scale). The nanotube electrode was reused 10 times with no distinguishable effect on performance, therefore demonstrating the stability of the electrode.
4.6. Rotating Electrode Reactor
The use of a rotating electrode in a reactor improves the mass transport by introducing turbulence/mixing and more contact between the contaminant and electrode(s), which overall improves the performance of the PEC reactor
[77][73]. The self-rotating design of Cho et al.
[78][74] moves both electrodes on a central axis in a tubular reactor, as shown in . Titania nanotubes as the photoanode and a titanium counter for the removal of methylene blue were used. The results from the experiments showed the importance of reducing the IR drop, by minimising the distance between electrodes, which subsequently improves the rate of degradation, as well as the importance of mass transport and the retention time, as the rotation speed was dependent on the inlet flow rate, the optimum thereof occurring at 90 RPM, but with a higher RPM, the retention time is lower due to the increased flow rate which results in lower rates of degradation.
Figure 18. Rotational reactor using titanium nanotube photoanode and titanium cathode. (Adapted with permission from
[78][74]: Cho, H.; Seo, H.S.; Joo, H.; Kim, J; Yoon, J. Performance evaluation of rotating photoelectrocatalytic reactor for enhanced degradation of methylene blue.
Korean J. Chem. Eng. 2017,
34, 2780–2786, doi:10.1007/s11814-017-0198-7. Copyright (2017), Springer Nature (Seoul, Korea)).
Xu et al.
[26][22] used a rotating disk reactor (RDR) with a TiO
2 photoelectrode prepared via a sol–gel method, with a copper cathode, in a solution of 3.5 mM Na
2SO
4 for the degradation of Rhodamine B, with a UV lamp (256 nm, 15 mWcm
−2), as depicted in . The photoelectrode is only partially submerged in the solution, the bottom segment acts as a conventional PEC cell and the top unsubmerged segment forms a thin film of the solution/contaminants on the surface of the photoelectrode and is exposed to air and the full irradiation. Increasing the rotation (RPM) improved the rate of Rhodamine B degradation up to 90 RPM, while other RDRs have shown improvement with increased RPM
[79,80][75][76]. The RDRs also show improvement compared to a conventional PEC cell, and the improvement is also more profound with higher contaminant loadings
[26,79,80][22][75][76]. Further improvement has been achieved by using an electrical discharge linear cutting machine to create a 3D pyramid structure (2, 4 and 6 mm height) on a titanium substrate to increase the geometric surface area, followed by dip coating to coat the substrate with TiO
2 [79][75]. A titanium nanotube RDR has also been used due to the enhancement that the 1D material has shown compared to particulate films
[81][77].
Figure 19. (
a) Schematic diagram of the side view of the TiO
2/Ti rotating disk PEC reactor. The figure is not to scale. 1, speed controller; 2, motor; 3, electrolytic cell; 4, TiO
2/Ti rotating disk anode; 5, cathode; 6, UV lamp; 7, aluminium foil; 8, DC power supply. (
b) The front view of the TiO
2/Ti rotating disk electrode. (Reproduced with permission from
[26][22]: Xu, Y.; He, Y.; Cao, X.; Zhong, D.; Jia, J. TiO
2/Ti rotating disk photoelectrocatalytic (PEC) reactor: A combination of highly effective thin-film PEC and conventional PEC processes on a single electrode.
Environ. Sci. Technol. 2008,
42, 2612–2617, doi:10.1021/es702921h. Copyright (2008), American Chemical Society (Washington, DC, USA)).
4.7. Optical Fibre Reactor
Several articles have reported using optical fibres in photocatalytic reactors
[82[78][79][80],
83,84], however, for PECs, only one such reactor has been reported
[85][81]. The use of optical fibres has the advantage of transporting light through the length of the fibre, improving the light illumination efficiency and increasing the surface area by using bundles of coated fibres
[84][80]. As optical fibres are used to transfer phonons considerable distances (in the Km range), the fibre needs to be treated (mechanically or chemically) to induce holes/cracks on the surface for the light to escape and be absorbed by the photocatalyst
[82][78]. To use the fibre as a photoelectrode, a conductive film needs to be applied. The design of Esquivel et al.
[85][81] () used SnO
2:Sb as a transparent conductive film with electrophoretically deposited TiO
2, and carbon cloth threads were used to increase the conductivity during the deposition as the SnO
2:Sb had a high resistance of 0.1 MΩ; alternatively, ITO has also applied to optic fibres
[86][82]. The reactor used a carbon cloth cathode, with 0.05 M Na
2SO
4 adjusted to pH 3, a fixed current of 1.0 mAcm
−2 was applied after 3 h and 80 mg L
−1 of H
2O
2 was produced, after which 15 mg L
−1 of Azo Orange II dye was added. After 60 min, a 50% decolourisation was observed when using PECs, though electrolytics showed comparable results. When analysing the total organic carbon (mineralisation), the PECs showed distinguishable results (
k = 0.0055 min
−1) compared to electrolysis (
k = 0.0035 min
−1), demonstrating that decolourisation is not the best method for evaluating reactors, as reported in other articles
[22,87][17][83].
Figure 20. (
a) Schematic representation of the experimental set-up, (
b) fibre optic photoanode. (Adapted with permission from
[85][81]: Esquivel, K.; Arriaga, L.G.; Rodríguez, F.J.; Martínez, L.; Godínez, L.A. Development of a TiO
2 modified optical fiber electrode and its incorporation into a photoelectrochemical reactor for wastewater treatment.
Water Res. 2009,
43, 3593–3603, doi:10.1016/j.watres.2009.05.035. Copyright (2009), Elsevier (Amsterdam, The Netherlands)).
4.8. Membrane Filter Reactor
Photocatalytic materials have been added to membranes to reduce the effect of membrane fouling, increasing the lifetime of the filter and by extension improving the effective cost per volume, as well as enabling the removal of contaminants that are smaller than the pore size of the membrane
[88][84]. These systems require the use of a conductive membrane or a secondary material to increase the conductivity, for example, carbon nanotubes
[89][85], graphitic carbon
[90][86], PEDOT
[91][87] or stainless steel mesh sandwiched in a nylon fibre membrane
[92][88] have been examined to facilitate electron transport, enabling the membrane to be used as a photoelectrode.
The design of Wang et al.
[89][85], shown in , used a porous ceramic membrane made from Al
2O
3.
Figure 21. Experimental set-up, insert photo of the reactor. (Adapted with permission from
[89][85]: Wang, X.; Wang, G.; Chen, S.; Fan, X.; Quan, X.; Yu, H. Integration of membrane filtration and photoelectrocatalysis on g-C
3N
4/CNTs/Al
2O
3 membrane with visible-light response for enhanced water treatment.
J. Membr. Sci. 2017,
541, 153–161, doi:10.1016/j.memsci.2017.06.046. Copyright (2017), Elsevier (Amsterdam, The Netherlands)).
To increase the electrical conductivity, carbon nanotubes were added to the membrane with graphitic carbon nitride used as the semiconducting material for the degradation of phenol (5 mg L
−1). After loading the additional materials on the membrane, the mean pore size was 297 nm; for comparison, phenol has an effective molecular diameter of 0.75 nm
[93][89]. The cathode was a titanium network, to which irradiation of 100 mWcm
−2 (>400 nm) was directed and passed through to the membrane. The degradation experiments showed a 7% reduction in phenol with the membrane only, and the reduction was attributed to surface absorption, and when applying irradiation, the reduction increased to 26%, and applied bias of +0.5 V, +1.0 V and +1.5 V resulted in a reduction of 29%, 71% and 94%, respectively; the improvement is attributed to the generation of •OH and reduced recombination due to the applied bias. Humic acid was used to examine the anti-fouling capability of the membrane, and by examining the permeability (L m
−2 h
−1 bar
−1), the highest permeability was observed when operated at +1.5 V under irradiation, ~3 times higher than the membrane only, demonstrating the anti-fouling capabilities of the PEC membrane, as demonstrated by others
[90,91][86][87].
The PEC membrane reactors can also be submerged in the solution, like the design of Gao et al.
[94][90], which can be operated in either a recirculating mode () or a continuous influence and effluent filter mode. In this design, the photoelectrode is a composite, where carbon fibre felt acts as the framework, with one side coated with ZnIn
2S
4 microspheres (0.4–0.8 μm) and the reverse side is coated with polyvinylidene fluoride, which increases the tensile strength of the composite and ensures that the solution passes thought the photoactive layer. The reactor was tested for the removal of tetracycline (4 mg L
−1) with a titanium plate counter electrode. The optimal bias was −0.3 V, and the cathodic bias could generate
O∙−2, which indicates the
O∙−2 is more beneficial for the degradation of tetracycline, which has also been observed for methylene blue with WO
3 [49][45]. The circulating operation had a removal rate of 87% after 3 h, and under constant operation (24 ± 0.1 L m
−2 h
−1), the average reduction was 71% in the first 12 h run, so additional runs were conducted to assess the stability; however, the subsequent runs had lower reduction rates compared to the initial run. This was attributed to absorption on the surface during the first run, resulting in a higher reduction; once the maximum absorption is achieved, the reduction is primarily via degradation.
Figure 22. Schematic of the submerged photoanode membrane and separate counter electrode. (Adapted with permission from
[94][90]: Martins, A.S.; Lachgar, A.; Boldrin Zanoni, M.V. Sandwich Nylon/stainless-steel/WO
3 membrane for the photoelectrocatalytic removal of Reactive Red 120 dye applied in a flow reactor.
Sep. Purif. Technol.
2020,
237, 116338, doi:10.1016/j.seppur.2019.116338. Copyright (2020), Elsevier (Amsterdam, The Netherlands)).
4.9. Two-Compartment Reactor
The electrodes can be separated into individual compartments, as shown in . The separation can be done by using a salt bridge, an ion exchange membrane or, as with the previously discussed cylindrical CPC design of Fernandez-Ibañez et al.
[65][61], a glass frit filled with an ionic conductive polymer (Nafion solution) to form the two-compartment reactor; however, these reactors are less commonly reported than the one-compartment reactor for degradation and disinfection. The two-compartment cell is more commonly reported for gaseous reactions to separate reactants and products, i.e., O
2, CO
2, CH
4, H
2 [95][91].
Figure 23. Two-compartment reactor set-up.
The work of Leng et al.
[96][92] demonstrated that using a one-compartment had a higher rate of aniline degradation compared to a two-compartment reactor which was separated using a low porosity glass frit, a TiO
2/Ti photoanode prepared via dip coating and a silver sheet counter electrode. The working volume was the same in both set-ups; however, in the two-compartment reactor, only the photoanode was used for aniline degradation, while in the single set-up, both electrodes can be used to generate ROS for the single purpose of aniline degradation; therefore, it would be surprising if the one-compartment reactor was not more effective. The rate constant for the one-compartment reactor was 1.3 times higher than the two-compartment reactor (
k = 0.3724 h
−1 vs.
k = 0.2817 h
−1); thus, the improvement is not major and the separation allows the use of different electrolytes in each compartment and can enable the production of a secondary product, e.g., H
2 or H
2O
2 [65,97,98][61][93][94].
There is also the ability for dual water treatment, and Byrne et al.
[99][95] examined the use of a two-compartment cell separated by a glass frit, using a TiO
2 photoanode prepared by electrophoretic deposition of P25 powder and a copper wire counter electrode for the oxidation of organic pollutants (oxalate) and recovery of metal ions, i.e., copper reduction. The anodic compartment contained 15 mM of potassium oxalate in KCl (pH = 6.5) and the cathodic compartment cell contained 1.25 mM CuSO
4 (pH = 1.5). The rector was irradiated with a 150 W Xe lamp and removed >94.4% of the copper in the cathodic solution and there was a 9% reduction in TOC for the removal of oxalate after 105 min. Byrne et al., subsequently reported the use of a two-compartment flat plate sandwich type reactor for the simultaneous oxidation of oxalate and the recovery of copper
[72][68]. The photoanode was P25 TiO
2 coated on FTO glass under back-face irradiation, with an anion exchange membrane separating the anode from a copper mesh counter electrode. The irradiation source was two Philips TLD 18 W/08 UVA lamps. The Faradaic yield for formic acid degradation was 126% which was explained by photocurrent losses due to residual O
2 at the anode. The Faradaic yield for copper recovery was 95.5%.
Although this review is based on aqueous PEC water treatment, PEC gaseous/air treatment has also been investigated
[100][96]. A brief example is the two-compartment design of Mei et al.
[101][97] tested with an AM 1.5 (100 mWcm
−2) source for the oxidation of sulphur dioxide (SO
2) to sulphate (
SO−24) which requires a strong alkaline electrolyte (NaOH was used as the anolyte in this study, pH = 13.65), with a nanorod-like hematite photoanode, which is reported to have high durability and corrosion resistance in alkali environments
[102][98]. The counter electrode was a gas diffusion electrode to produce H
2O
2, the catholyte was 0.1 M Na
2SO
4 in H
2SO
4 (pH = 3) and the electrolytes were separated by a bipolar membrane. The addition of SO
2 also increased the photocurrent to 1.2 mAcm
−2, leading to improved H
2O
2 concentrations (58.8 μmolL
−1h
−1cm
−2). Therefore, the system facilitates the synergistic treatment of desulphurisation of flue gas and simultaneous production of high-value H
2O
2, of which the price per mole is 1.5 times the value of H
2.
4.10. Hybrid System
In a hybrid system, there are two separate solutions/cells, and unlike the two-compartment reactor there is no ionic transport between the solutions; instead, the electrons are transported via an external circuit, as shown in . One of the cells can act as a photocatalytic fuel cell to generate a potential bias that can power the separate PEC cell. In the design of Liu et al.
[103][99], the fuel cell used a TiO
2 nanotube array as the photoanode and a Pt-black/Pt counter in a solution of 0.05 M acetic acid and 0.1 M Na
2SO
4 which generated a 0.608 V open-circuit voltage and a short-circuit current of 0.261 mA. The PEC cell used a nanotube array as a photoanode and a Pt counter for the degradation of 0.045 mM tetracycline. The inclusion of the fuel cell increased the rate constant from 0.318 h
−1 photocatalytically, i.e., without the fuel cell, to 0.555 h
−1. The configuration of Nordin et al.
[104][100] examined the use of three different photocatalysts (TiO
2, ZnO, α-Fe
2O
3) immobilised on carbon cloth for the fuel cell photoelectrode, of which ZnO generated the highest open-circuit potential of 82.3 mV and a photocurrent of ~0.085 mA. The second cell used a carbon plate anode and an iron plate cathode, forming a peroxi-coagulation cell. The reactor was tested using 10 mgL
−1 of amaranth dye in both cells, and the fuel cell removed 83.3%, 93.8% and 4.0% and the peroxi-coagulation cell 91.4%, 86.9% and 87.5% for TiO
2, ZnO and α-Fe
2O
3, respectively.
Figure 24. Hybrid system with a fuel cell used to self-bias the system and a secondary compartment for additional reactions.
4.11. Three-Dimensional Electrode Reactor
The final and somewhat derivative category of PECs is the use of a three-dimensional electrode. The anode and cathode in this instance are traditional electrochemical electrodes. The 3D electrode is the photocatalyst and is used as a secondary method to enhance the performance by utilising photocatalysis and potentially by acting as a bipolar electrode. The 3D electrode can be in the form of a slurry reactor
[105][101], immobilised onto millimeter-scale substrates to form a packed bed reactor
[106][102] or as a singular porous electrode
[107][103].
The slurry design of An et al.
[105][101], shown in , used a stainless steel anode and cathode, with granulated activated carbon and TiO
2 as the 3D electrode for the degradation of reactive brilliant red X-3B. The reactor was aerated from the bottom with the use of a micropore plate to provide oxygen and mixing and keep the particulates in suspension. The addition of the 3D electrode improved the kinetic rate
(k = 0.1067 min
−1) compared to only photocatalytic degradation (
k = 0.0351 min
−1) or electrochemical oxidation (
k = 0.0562 min
−1). Post-treatment filtration is still required to separate the photocatalyst from the solution, and cost/energy analysis also needs to be performed to examine if the additional complexity and input energy are worth the increased efficiency.
Figure 25. Schematic diagram of the three-dimensional electrode slurry photocatalytic reactor. (1) Cathode; (2) outlet of recycled water; (3) GAC layer; (4) micropore plate; (5) inlet of pressured air; (6) inlet of recycled water; (7) titanium dioxide layer; (8) anode; (9) UV irradiation. (Reproduced with permission from
[105][101]: An, T.; Zhu, X.; Xiong, Y. Synergic degradation of reactive brilliant red x-3b using three dimension electrode-photocatalytic reactor.
J. Environ. Sci. Health A 2001,
36, 2069–2082, doi:10.1081/ESE-100107449. Copyright (2001), Taylor & Francis (Abingdon, UK)).
To remove the need for filtration, the photocatalyst can be immobilised onto millimeter-scale substrates, i.e., beads or Raschig rings
[108][104], to be used as the 3D electrode, as in the design of Liu et al.
[106][102] shown in .
Figure 26. Schematic diagram of the three-dimensional electrode packed bed photocatalytic reactor. (Reproduced with permission from
[106][102]: Liu, R.; Zhang, Y. Highly efficient degradation of berberine chloride form wastewater by a novel three-dimensional electrode photoelectrocatalytic system.
Environ. Sci. Pollut. Res. 2018,
25, 9873–9886, doi:10.1007/s11356-018-1293-y. Copyright (2018), Springer Nature (Heidelberg, Germany)).
Their system used Fe
2O
3/graphite and TiO
2-coated glass beads as the 3D electrode. The anode and cathode were titanium and stainless steel, respectively, operated with a current density of 9 mAcm
−2 and with a 40 W UV lamp (78 μWcm
−2). The inclusion of the 3D electrode improved the rate of berberine chloride form degradation, and a rate constant (
k) of 0.015 min
−1 was achieved with the 3D electrode under irradiation, compared to
k = 0.007 min
−1 without irradiation and
k = 0.001 min
−1 without irradiation and the 3D electrode. The efficiency analysis shows that the 3D electrode had a higher mineralisation current efficiency, monitored by TOC and using Equation (7)
[109][105], where n is the number of electrons consumed during mineralisation, F is the Faraday constant (96,487 C mol
−1), V is the volume (L), ΔTOC is the amount of TOC removed (mg L
−1), 4.32 × 10
7 is a conversion factor (3600 s h
−1 × 12,000 C mol
−1), m is the number of carbon atoms in the compound, I is the current (A) and t is the time elapsed (h). The 3D electrode also had a lower energy consumption per unit of TOC mass and therefore, by extension, a lower energy cost calculated by Equation (8), where Energy
(TOC) is the energy required for a unit of TOC (kWh mg
−1(TOC)), P is the total electrical power of all used appliances (kW), t is the time elapsed (h) and Δ(TOC) is the amount of TOC removed (mg). Alternatively, the energy required can be expressed as per volume for a set amount degradation/order of efficiency (kWh m
−3) using Equation (9), where V is the volume (m
3)
[110][106].
The 3D electrode can also take the form of a singular porous bipolar electrode, as with the design of Mesones et al.
[107][103], in which the 3D electrode is a composite of granular activated carbon and TiO
2 contained within a basket (), and a dimensionally stable anode (DSA) made of RuOx/Ti and a stainless steel cathode were used, for the inactivation of
E. coli K12 in a high-salt solution (NaCl 35 g L
−1) similar to fish farm seawater. The results demonstrated that there was no synergic effect when combining the photocatalytic process with the electrochemical process. The electrochemical set-up which produced chlorine radicals had the lowest energy requirement of 0.007 kWh m
−3 at 0.1 mA cm
−2; the inclusion of the lamp and 3D electrode increased the energy requirement to 2.2 kWh m
−3.
Figure 27. Schematic representation of the 3D PEC reactor, (
a) upper view and (
b) front view. (Adapted with permission from
[107][103]: Mesones, S.; Mena, E.; López-Muñoz, M.J.; Adán, C.; Marugán, J. Synergistic and antagonistic effects in the photoelectrocatalytic disinfection of water with TiO
2 supported on activated carbon as a bipolar electrode in a novel 3D photoelectrochemical reactor.
Sep. Purif. Technol. 2020,
247, 117002, doi:10.1016/j.seppur.2020.117002. Copyright (2020), Elsevier (Amsterdam, The Netherlands)).