Physical Cleaning
The initial step in the physical cleaning involves the unwinding and redissolution of the foulant layer into the feed stream. Direct flushing at high cross-flow velocity is applied to remove firmly attached foulants. Loosely bounded foulants can be easily removed by flushing the membrane module with water. For plate and flat sheet modules, backflushing can be applied to reduce the fouling within pores and to eliminate the cake layer or gel layer formation on the active site of the membrane. In contrast, the non-homogeneous flow through the pores restricts its applicability. Recently, researchers reported the energy cost and an ultra-sonication cleaning to remove foulants, but the main challenges are scaling up. Air scouring is utilized as a cleaning strategy to control the membrane fouling effect and to prevent any complicated reaction before it occurred [
].
The cake layer formed in the FO and RO processes is very different. Compressible foulants in RO formed a dense cake layer, which can reduce flux and increase the energy due to increasing the hydraulic resistance along the membrane. On the other hand, the flux decline in the FO was due to cake formation on the membrane surface because of the enhanced osmotic pressure [
]. The fouling in FO was reversible and not compressed when compared to the RO mode, which involved the hydraulic pressure, and may affect the morphology of the alginate gel. As a result, cleaning the FO membrane was easier than the RO mode due to lower hydraulic compaction of the foulant layer [
]. Many factors can affect the efficiency of membrane cleanings such as type of feed water, membrane type, duration frequency, and intensity [
]. Surface flushing is an effective method for cleaning the reversible foulant on the FO membrane surface. The membrane can simply obtain cleaning efficiency by around 98% with increased cross-flow velocity and cleaning duration. Additionally, air bubbles can be added to enhance the cleaning efficiency due to increasing shear force on the membrane and the turbulence, and reducing the time of cleaning. Hence, this may achieve 100% efficiency without any chemical reagents [
]. However, this method is insufficient for the RO membrane due to the porous factor of the support layer, which can decline the shear force and reduce the cleaning efficiency [
]. Osmotic backwashing is another physical cleaning method that can be used for the FO membrane. The osmotic backwash is implemented by reducing the salinity of the draw solution and increasing the feed solution salinity or swapping the feed with the draw solution inlet to break down the foulant on the support layer [
]. Some studies recommended osmotic backwash as an effective cleaning method, especially with membrane fouled by complex water such as anaerobic digester concentrate, MBR feed water, industrial wastewater, and municipal wastewater [
,
,
,
,
].
In contrast, other studies reported low flux recovery obtained when using osmotic backwashing for membrane cleaning [
,
]. Some foulants may form gypsum in the support layer and required additional hydraulic backwash to obtain 100% flux recovery, especially in the RO mode due to a compressed foulant. In case of using the cellulose acetate (CA) membrane for both FO and RO, apply 4 M NaCl Draw solution for FO and, under 28 bars, hydraulic pressure for RO for 20 h until the flux notably reduced. The cleaning process by rinsing the foulant membrane with 50 mM NaCl solution for 15 min found that the flux on the FO membrane recovered by around 100%, while, for RO, was around 70% [
]. Therefore, osmotic backwashing can be used for the FO mode due to the lower compaction of foulant on the membrane while, in case of the RO, the suitable method for physical cleaning is hydraulic backwashing in case of cleaning without chemical reagents.
Chemical Cleaning
Since complete removal of foulants is not possible, using physical cleaning, various chemicals are used to break down the chemical structure and bonding of foulants with the membrane. Chemicals used in cleaning reacts with foulants to enhance their solubility by the degradation of foulants in a more soluble form. Surfactants and wetting agents are also used as cleaning chemicals since they can easily remove the foulants inside the pore. The sanitization operation is performed to avoid the growth of microorganisms on the membrane surface. In some studies, hypochlorite is applied as a disinfectant agent. Mass transfer of foulants and chemicals to and from the membrane decides the efficiency of cleaning. Circulation time and flow rate at various pH of cleaning with chemicals is a critical factor in obtaining highly efficient cleaning. In general acids, bases, steam, gas sterilization, and sequestrants are used as cleaning agents. Acid solution mainly reduces efficiently inorganic fouling while the whole alkali solution is responsible for removing organic fouling [
142].
Information about the main components of the water source and fouling composition helps to obtain better cleaning in a short amount of time while considering safety, cost, and the impact of the cleaning agent to the environment and membrane [
143]. Gao, Liang et al., 2011, reported that sometimes two agents need to be mixed to reduce foulant from the surface of one membrane [
131]. Tragardh (1989) stated that chemical cleaning should follow some steps to avoid damaging the system and sustainable working such as keeping the fouling loose and solute to avert forming new fouling and keep the membrane clean and safe with all other wetted surfaces sterilized. Additionally, the efficiency of the chemical cleaning depends on the flow rate of the cleaning, concentration, and temperature of cleaning material and the percentage of the foulant [
144]. The positive effect of the interaction between the foulant and the chemical agent can be presented in three ways: (i) the foulant can be removed, (ii) the morphology of the foulant can be changed such as swelling or compacting, and (iii) the hydrophobic or charged is modified because the surface chemistry of the deposit may be altered [
145]. This cleaning agent may react chemically with foulant so they can break down the cohesion force between the foulant ions and reduce the adhesion force between the foulants and the membrane surface.
In the case of the FO membrane, thin-film composite (TFC) required chemical cleaning due to strong adhesion with alginate when compared to the cellulose triacetate (CTA) membrane [
103]. Sodium hydroxide (NaOH), sodium ethylenediaminetetraacetic acid (EDTA), and sodium hypochlorite (NaOCl) with a concentration range between 0.5–1.0%. Several studies reported that chemical cleaning could achieve highly efficient membrane cleaning from organic foulant, which may have a strong interaction to the membrane surface [
136,
146,
147,
148,
149]. Although chemical cleaning has a high cleaning efficiency, hardly removed foulant from membrane pores [
136], can be harmful to the FO membrane, may reduce the membrane life [
141], and might cause an environmental problem due to the effluent stream during the cleaning process [
103,
150]. For an example of RO mode, cleaning reagents chosen for an organic foulant similar to FO as NaOH as an alkaline solution, certified grade disodium ethylenediaminetetraacetate (Na2-EDTA) as a metal chelating reagent, certified grade sodium dodecyl sulphate (SDS) as an anionic surfactant, and NaCl as a salt cleaning solution at pH 11 [
151]. Thin-film composite LFC-1 as an RO membrane was used, and the foulants within the irreversible fouling layer on the membrane surface, which may have a strong intermolecular adhesion force between particles from wastewater effluent [
152]. The cleaning process starts by adding the chemical reagent as a feed solution for a suitable duration time, which may also affect the cleaning efficiency. Some flounts required one chemical cleaning reagent to obtain a high cleaning efficiency, while others need to combine more than one at the same time. Generally, Ang, Yip et al. (2011) stated that adding NaOH as a cleaning reagent (alone or combined with another reagent) can improve the cleaning performance due to its capability to loosen the fouling layer.
Factors Influencing Cleaning Efficiency
Many factors impact the cleaning efficiency of the fouled membrane, such as the sequence of the cleaning steps. Practically, physical cleaning can remove loose particles on the membrane surface (reversible fouling). Generally, physical cleaning cannot retrieve membrane permeability effectively, and a combination of chemical and physical cleanings are usually used for the removal of such fouling [
,
]. In addition, the sequence in the chemical cleaning may affect the membrane permeability degree. Some studies reported that an alkaline cleaning substance could be more efficient when followed by an acid cleaning substance better than when cleaning the membrane from dominant organic matter foulants [
,
]. Other studies found that precipitation of an inorganic scaling or metal hydroxide on the membrane surface prefers acid than the alkali substance sequence for the cleaning process [
,
].
Temperature is considered another factor that may take effect on the membrane cleaning strategy. Increasing temperature is substantial for cleaning the fouling membrane by increasing solubility due to reactivity of functional groups at high temperatures of the organic matters and increasing mass transfer dispersive with mechanical destabilization of biofilm layers on the membrane surface [
]. In contrast, high-temperature biofilm tends to precipitate on the membrane surface in the form of calcium carbonate, ferric hydroxide, and silicates, which makes the process more difficult to separate [
].
Increasing the pH has a direct proportion with membrane cleaning efficiency in case all carboxylic functional groups of EDTA are deprotonated [
]. For instance, increasing pH from 4.9–11.0 will affect the cleaning percentage from 25%–44% and, at pH 11, are very easy to break down the gel layer on the membrane surface when compared to the lower pH. While Ang, Lee et al. (2006) found that, in the case of sodium dodecyl sulphate (SDS), the effect of the pH is very low on the cleaning efficiency because the chemical reaction between the foulants and the SDS effect slightly by changing pH [
].
shows the cleaning protocols for fouled membranes. Furthermore, Al-Amoudi, A. concluded that permeable efficiency relies on the membrane cleaning step within the membrane process [
].
Table 3. Cleaning protocols for fouled forward osmosis (FO) membranes.